The influence of on-pump and off-pump coronary artery bypass grafting on hemorheological parameters

被引:17
作者
Papp, J. [1 ]
Toth, A. [1 ]
Sandor, B. [1 ]
Kiss, R. [2 ]
Rabai, M. [1 ,3 ]
Kenyeres, P. [1 ]
Juricskay, I. [1 ]
Kesmarky, G. [1 ]
Szabados, S. [2 ]
Toth, K. [1 ]
机构
[1] Univ Pecs, Dept Med 1, Sch Med, H-7623 Pecs, Hungary
[2] Univ Pecs, Heart Inst, Sch Med, H-7623 Pecs, Hungary
[3] Univ So Calif, Keck Sch Med, Dept Physiol & Biophys, Los Angeles, CA 90033 USA
关键词
Coronary artery bypass grafting; on-pump; off-pump; viscosity; erythrocyte aggregation; erythrocyte deformability; platelet aggregation; scanning electron microscopy; CELL ANALYZER LORCA; CARDIOPULMONARY BYPASS; EXTRACORPOREAL-CIRCULATION; ERYTHROCYTE AGGREGATION; PLATELET-AGGREGATION; BLOOD RHEOLOGY; WHOLE-BLOOD; FOLLOW-UP; VISCOSITY; SURGERY;
D O I
10.3233/CH-2011-1484
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Conditions during coronary artery bypass grafting (CABG) performed on beating heart (off-pump) are more physiological than using extracorporeal perfusion (on-pump). The present study aims to examine the hemorheological aspects of the two techniques. Blood samples were taken from patients undergoing on-pump (n = 25) and off-pump (n = 22) CABG, upon arrival to the operating theatre, after 20 and 40 minutes during the operation, after closing the thorax, on the 1st and 2nd postoperative days, and during the 2nd and 6th month control check-ups. Hematocrit (Hct), plasma and whole blood viscosity (PV, WBV; Hevimet 40 capillary viscometer), red blood cell (RBC) aggregation (Myrenne RBC aggregometer, LORCA) and deformability (LORCA, Carat FT-1 filtrometer), and platelet aggregation (Carat TX4 aggregometer) were determined. The morphology of red blood cells was investigated by scanning electron microscopy (SEM). Hct, PV, WBV and RBC aggregation decreased significantly during the early phase of the surgery, they started to recover during the postoperative period, and reached the baseline values by the 2nd and 6th month control check-ups. These parameters were significantly lower in samples taken after 20 and 40 minutes in the on-pump group. SEM showed rather damaged and malformed cells in case of on-pump surgery. Ektacytometry showed no significant difference, but RBC deformability was impaired during on-pump surgery when measured by filtrometry. The decrease in platelet aggregation was more pronounced by the end of surgery in case of on-pump technique. During CABG rheological parameters change less when using the off-pump method, and mechanical damage of RBCs are also smaller. The off-pump technique seems to be favorable from a hemorhelogical point of view.
引用
收藏
页码:331 / 346
页数:16
相关论文
共 43 条
[1]   Reduced postoperative blood loss and transfusion requirement after beating-heart coronary operations: A prospective randomized study [J].
Ascione, R ;
Williams, S ;
Lloyd, CT ;
Sundaramoorthi, T ;
Pitsis, AA ;
Angelini, GD .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2001, 121 (04) :689-696
[2]  
Attaran S., 2011, INTERACT CARDI 0623
[3]  
Baker IA, 2002, THROMB HAEMOSTASIS, V87, P421
[4]   Comparison of early platelet activation in patients undergoing on-pump versus off-pump coronary artery bypass surgery [J].
Ballotta, Andrea ;
Saleh, Hisham Z. ;
El Baghdady, Hisham W. ;
Gomaa, Magdi ;
Belloli, Federica ;
Kandil, Hassan ;
Balbaa, Yahia ;
Bettini, Fabrizio ;
Bossone, Eduardo ;
Menicanti, Lorenzo ;
Frigiola, Alessandro ;
Bellucci, Carmen ;
Mehta, Rajendra H. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2007, 134 (01) :132-138
[5]   New guidelines for hemorheological laboratory techniques [J].
Baskurt, Oguz K. ;
Boynard, Michel ;
Cokelet, Giles C. ;
Connes, Philippe ;
Cooke, Brian M. ;
Forconi, Sandro ;
Liao, Fulong ;
Hardeman, Max R. ;
Jung, Friedrich ;
Meiselman, Herbert J. ;
Nash, Gerard ;
Nemeth, Norbert ;
Neu, Bjoern ;
Sandhagen, Bo ;
Shin, Sehyun ;
Thurston, George ;
Wautier, Jean Luc .
CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2009, 42 (02) :75-97
[6]  
BASKURT OK, 1991, CLIN HEMORHEOL, V11, P121
[7]  
BAUERSACHS RM, 1989, CLIN HEMORHEOL, V9, P1
[8]   Can platelet aggregometry be standardized? [J].
Breddin, HK .
PLATELETS, 2005, 16 (3-4) :151-158
[9]   Off pump coronary artery bypass: a passing fad or ready for prime time? [J].
Briffa, Norman .
EUROPEAN HEART JOURNAL, 2008, 29 (11) :1346-1349
[10]   MICROEMBOLI DURING CORONARY-ARTERY BYPASS-GRAFTING - GENESIS AND EFFECT AN OUTCOME [J].
CLARK, RE ;
BRILLMAN, J ;
DAVIS, DA ;
LOVELL, MR ;
PRICE, TRP ;
MAGOVERN, GJ .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1995, 109 (02) :249-258