Confounding factors in the use of the zero-heat-flow method for non-invasive muscle temperature measurement

被引:24
作者
Brajkovic, D
Ducharme, M
机构
[1] Def Res & Dev Canada Toronto, Human Protect & Performance Grp, Toronto, ON M3M 3B9, Canada
[2] Univ Ottawa, Sch Human Kinet, Ottawa, ON K1N 6N5, Canada
关键词
deep tissue temperature; thigh temperature; core temperature;
D O I
10.1007/s00421-005-1336-1
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
This study evaluated a zero-heat-flow (ZHF), non-invasive temperature probe for in-vivo measurement of resting muscle temperature for up to 2 cm below the skin surface. The ZHF probe works by preventing heat loss from the tissue below the probe by actively heating the tissue until no temperature gradient exists across the probe. The skin temperature under the probe is then used as an indicator of the muscle temperature below. Eight subjects sat for 130 min during exposure to 28 degrees C air. Vastus lateralis (lateral thigh) muscle temperature was measured non-invasively using a ZHF probe which covered an invasive multicouple probe (which measured tissue temperature 0.5 cm, 1 cm, 1.5 cm, and 2 cm below the skin) located 15 cm superior to the patella (T-covered). T-covered was evaluated against an uncovered control multicouple probe located 20 cm superior to the patella (T-uncovered). Rectal temperature and lateral thigh skin temperature were also measured. Mean T-uncovered (based on average temperatures at the 0.5 cm, 1 cm, 1.5 cm, and 2 cm depths) and Mean T-covered were similar from time 0 min to 60 min. However, when the ZHF was turned on at 70 min, Mean T-covered increased by 2.11 +/- 0.20 degrees C by 130 min, while T-uncovered remained stable. The ZHF probe temperature was similar to T-covered at 1 cm and after time 85 min, significantly higher than T-covered at the 0.5 cm, 1.5 cm, and 2 cm depths; however from a physiological standpoint, the temperatures between the different depths and the ZHF probe could be considered uniform ( <= 0.2 degrees C separation). Rectal and thigh skin temperatures were stable at 36.99 +/- 0.08 degrees C and 32.82 +/- 0.23 degrees C, respectively. In conclusion, the non- invasive ZHF probe temperature was similar to the T-covered temperatures directly measured up to 2 cm beneath the surface of the thigh, but all T-covered temperatures were not representative of the true muscle temperature up to 2 cm below the skin because the ZHF probe heated the muscle by 2.11 +/- 0.20 degrees C during its operation.
引用
收藏
页码:386 / 391
页数:6
相关论文
共 20 条
  • [11] Muscle temperature transients before, during, and after exercise measured using an intramuscular multisensor probe
    Kenny, GP
    Reardon, FD
    Zaleski, W
    Reardon, ML
    Haman, F
    Ducharme, MB
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 2003, 94 (06) : 2350 - 2357
  • [12] Tissue temperature transients in resting contra-lateral leg muscle tissue during isolated knee extension
    Kenny, GP
    Reardon, FD
    Ducharme, MB
    Reardon, ML
    Zaleski, W
    [J]. CANADIAN JOURNAL OF APPLIED PHYSIOLOGY-REVUE CANADIENNE DE PHYSIOLOGIE APPLIQUEE, 2002, 27 (06): : 535 - 550
  • [13] Ultra-sound imaging for precision implantation of a multi sensor temperature probe in skeletal muscle tissue
    Kenny, GP
    Reardon, FD
    Ducharme, MB
    Reardon, ML
    Zaleski, W
    [J]. CANADIAN JOURNAL OF APPLIED PHYSIOLOGY-REVUE CANADIENNE DE PHYSIOLOGIE APPLIQUEE, 2002, 27 (05): : 527 - 532
  • [14] TEMPERATURE DISTRIBUTION MEASUREMENTS IN TWO-DIMENSIONAL NMR IMAGING
    PARKER, DL
    SMITH, V
    SHELDON, P
    CROOKS, LE
    FUSSELL, L
    [J]. MEDICAL PHYSICS, 1983, 10 (03) : 321 - 325
  • [15] MUSCLE TEMPERATURE DURING SUBMAXIMAL EXERCISE IN MAN
    SALTIN, B
    GAGGE, AP
    STOLWIJK, JA
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1968, 25 (06) : 679 - &
  • [16] ESOPHAGEAL RECTAL AND MUSCLE TEMPERATURE DURING EXERCISE
    SALTIN, B
    HERMANSEN, L
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1966, 21 (06) : 1757 - +
  • [17] TOGAWA T, 1979, Resuscitation, V7, P53, DOI 10.1016/0300-9572(79)90015-7
  • [18] TOGAWA T, 1979, NONINVASIVE PHYSL ME, P261
  • [19] Evaluation of a newly developed monitor of deep body temperature
    Yamakage M.
    Iwasaki S.
    Namiki A.
    [J]. Journal of Anesthesia, 2002, 16 (4) : 354 - 357
  • [20] [No title captured]