Assessment of true intraocular pressure: The gap between theory and practical data

被引:129
作者
Chihara, Etsuo [1 ]
机构
[1] Sensho Kai Eye Inst, Kyoto 6110043, Japan
关键词
corneal thickness; corneal topography; correction algorithm; glaucoma; intraocular pressure; modulus of elasticity; refractive surgery; tonometer;
D O I
10.1016/j.survophthal.2008.02.005
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
A precise assessment of the intraocular pressure (TOP) is crucial for diagnosis and decision making regarding treatment modalities in patients with glaucoma. Recent epidemiologic studies show that a difference of only 1 mm Hg in the mean TOP may be critical enough to determine the visual field prognosis in patients with glaucoma. However, the Goldmann applanation tonometer, which is current gold standard, is not precise enough to measure the true TOP within an error of I rum Hg. There are many clinically proposed correction algorithms to correctly measure TOP. However, corrections using only the central corneal thickness and curvature may not be sufficient in each individual case. In this article, previously reported theoretical equations about the effects of corneal topography, modulus of elasticity, and tear film on Goldmann applanation tonometric TOP readings were reviewed, and their discrepancies with clinical or experimental data were analyzed. Thereafter, new tonometers such as the dynamic contour tonometer, the rebound tonometer, and the ocular response analyzer were compared with the Goldmann applanation tonometer and other popular tonometers.
引用
收藏
页码:203 / 218
页数:16
相关论文
共 161 条
[1]  
Agudelo LM, 2002, J REFRACT SURG, V18, P472
[2]   Biomechanical modeling of refractive corneal surgery [J].
Alastrué, V ;
Calvo, B ;
Peña, E ;
Doblaré, M .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2006, 128 (01) :150-160
[3]  
ARGUS WA, 2001, OPHTHALMOLOGY, V102, P1364
[4]   Underestimation of intraocular pressure in eyes after laser in situ keratomileusis [J].
Arimoto, A ;
Shimizu, K ;
Shoji, N ;
Enomoto, K ;
Kohara, M .
JAPANESE JOURNAL OF OPHTHALMOLOGY, 2002, 46 (06) :645-649
[5]  
Barreto Jr Jackson, 2006, Clinics, V61, P511, DOI 10.1590/S1807-59322006000600004
[6]  
Baypaktar S, 2005, EUR J OPHTHALMOL, V15, P81
[7]   Central corneal thickness determined with optical coherence tomography in various types of glaucoma [J].
Bechmann, M ;
Thiel, MJ ;
Roesen, B ;
Ullrich, S ;
Ulbig, MW ;
Ludwig, K .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2000, 84 (11) :1233-1237
[8]  
Bhan A, 2002, INVEST OPHTH VIS SCI, V43, P1389
[9]   Disposable devices for measuring intraocular pressure: a clinical study to assess their accuracy [J].
Bhatnagar, A ;
Gupta, AK .
EYE, 2005, 19 (07) :752-754
[10]  
BLATT VN, 1964, KLIN MBL AUGENHKD, V145, P680