Endovascular Stent-graft Treatment for Stanford Type A Aortic Dissection

被引:75
作者
Ye, C. [1 ]
Chang, G. [1 ]
Li, S. [1 ]
Hu, Z. [1 ]
Yao, C. [1 ]
Chen, W. [2 ]
Li, X. [1 ]
Wang, S. [1 ]
机构
[1] Sun Yat Sen Univ, Affiliated Hosp 1, Dept Vasc Surg, Guangzhou 510080, Guangdong, Peoples R China
[2] Sun Yat Sen Univ, Affiliated Hosp 1, Dept Intervent Radiol, Guangzhou 510080, Guangdong, Peoples R China
关键词
Aortic dissection; DeBakey type I; Endovascular treatment; Stanford type A dissection; SURGICAL-TREATMENT; TRANSLUMINAL PLACEMENT; THORACIC AORTA; ARCH; ANEURYSMS; MANAGEMENT; EXCLUSION; REPAIR;
D O I
10.1016/j.ejvs.2011.08.015
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: The aim of the study is to summarise our experience of endovascular stent grafting for Stanford type A aortic dissection. Design: Retrospective analysis at single centre. Methods: From January 2001 to January 2009, we treated 45 cases of Stanford type A aortic dissection with endovascular stent grafting. The entry tear was located at the ascending aorta in 10 cases (DeBakey type I), the aortic arch in 14 cases and the distal aortic arch or proximal descending aorta in 21 cases in which the ascending aorta was also involved by the dissection. Results: The surgical success rate was 97.8% (44/45) and 30-day mortality rate was 6.7% (3/45). Type I endoleaks occurred in 10 cases: one patient died intra-operatively, four were successfully treated with ballooning, four were sealed with aortic cuffs and one case caused by left subclavian artery (LSA) reflux was sealed with an occluder. Average follow-up time was 35.5 +/- 5.4 months. Up to the most recent review or death; 32 patients had complete thrombosis and 10 had partial thrombosis inside the false lumen. Two deaths occurred after 30-days postoperatively. Conclusion: Endovascular stent-graft treatment is a minimally invasive and effective method to treat Stanford type A aortic dissection. (C) 2011 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:787 / 794
页数:8
相关论文
共 50 条
[31]   Distal Stent Graft-Induced New Entry: An Emerging Complication of Endovascular Treatment in Aortic Dissection [J].
Pantaleo, Antonio ;
Jafrancesco, Giuliano ;
Buia, Francesco ;
Leone, Alessandro ;
Lovato, Luigi ;
Russo, Vincenzo ;
Di Marco, Luca ;
Di Bartolomeo, Roberto ;
Pacini, Davide .
ANNALS OF THORACIC SURGERY, 2016, 102 (02) :527-533
[32]   Is Endovascular Stent-Graft Treatment of Primary Aortoesophageal Fistula Worthwhile? [J].
Malas, Mahmoud B. ;
Saha, Surajit ;
Qazi, Umair ;
Duncan, Mark ;
Perler, Bruce A. ;
Freischlag, Julie A. ;
Veith, Frank J. .
VASCULAR AND ENDOVASCULAR SURGERY, 2011, 45 (01) :83-89
[33]   Endovascular Treatment of Descending Thoracic Aortic Aneurysms with the EndoFit Stent-Graft [J].
N. Saratzis ;
Athanasios Saratzis ;
N. Melas ;
G. Ginis ;
A. Lioupis ;
D. Lykopoulos ;
J. Lazaridis ;
Dimitrios Kiskinis .
CardioVascular and Interventional Radiology, 2007, 30
[34]   Fenestrated Aortic Arch Stent-Graft Malfunction With Endovascular Salvage [J].
Varcoe, Ramon L. ;
Lennox, Andrew F. .
JOURNAL OF ENDOVASCULAR THERAPY, 2013, 20 (02) :242-248
[35]   Endovascular treatment of descending thoracic aortic aneurysms with the EndoFit stent-graft [J].
Saratzis, N. ;
Saratzis, Athanasios ;
Melas, N. ;
Ginis, G. ;
Lioupis, A. ;
Lykopoulos, D. ;
Lazaridis, J. ;
Kiskinis, Dimitrios .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2007, 30 (02) :177-181
[36]   Risk factors for stent graft-induced new entry after thoracic endovascular aortic repair for Stanford type B aortic dissection [J].
Jang, Hyunsik ;
Kim, Man-Deuk ;
Kim, Gyoung Min ;
Won, Jong Yun ;
Ko, Young-Guk ;
Choi, Donghoon ;
Joo, Hyun-Chul ;
Lee, Do Yun .
JOURNAL OF VASCULAR SURGERY, 2017, 65 (03) :676-685
[37]   Surgical treatment for retrograde type A aortic dissection after endovascular stent graft placement for type B dissection [J].
Lu, Shuyang ;
Lai, Hao ;
Wang, Chunsheng ;
Sun, Xiaoning ;
Hong, Tao ;
Song, Kai ;
Yuan, Zhenkai ;
Liu, Xueling .
INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2012, 14 (05) :538-542
[38]   Use of a stent-graft and vascular occlude to treat primary and re-entry tears in a patient with a Stanford type B aortic dissection [J].
Shi, Huihua ;
Lu, Min ;
Jiang, Mier .
REVISTA BRASILEIRA DE CIRURGIA CARDIOVASCULAR, 2013, 28 (04) :550-554
[39]   Fenestrated Stent-Graft Facilitates Emergency Endovascular Therapy for Blunt Aortic Injury [J].
Kurimoto, Yoshihiko ;
Asai, Yasufumi ;
Nara, Satoshi ;
Mori, Kazuhisa ;
Hase, Mamoru ;
Ohori, Syunsuke ;
Ito, Toshiro ;
Baba, Toshio ;
Kawaharada, Nobuyoshi ;
Higami, Tetsuya .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2009, 66 (04) :974-978
[40]   Development of new endovascular stent-graft system for type B thoracic aortic dissection with finite element analysis and experimental verification [J].
Zhou, Xiaochen ;
Yang, Fan ;
Gong, Xiaoyan ;
Zhao, Ming ;
Zheng, Yufeng ;
Sun, Zhili .
JOURNAL OF MATERIALS SCIENCE & TECHNOLOGY, 2019, 35 (11) :2682-2692