Steady-state imaging with inhomogeneous magnetization transfer contrast using multiband radiofrequency pulses

被引:13
|
作者
Malik, Shaihan J. [1 ,2 ]
Teixeira, Rui P. A. G. [1 ,2 ]
West, Daniel J. [1 ,2 ]
Wood, Tobias C. [3 ]
Hajnal, Joseph V. [1 ,2 ]
机构
[1] Kings Coll London, Sch Biomed Engn & Imaging Sci, London, England
[2] Kings Coll London, Ctr Developing Brain, London, England
[3] Kings Coll London, Inst Psychiat Psychol & Neurosci, Neuroimaging Dept, London, England
基金
英国工程与自然科学研究理事会;
关键词
dipolar order; ihMT; inhomogeneous MT; magnetization transfer; myelin imaging; BROADENED LINES; IN-VIVO; IHMT; SENSITIVITY; EXCHANGE; ORIGIN; MODEL;
D O I
10.1002/mrm.27984
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Inhomogeneous magnetization transfer (ihMT) is an emerging form of MRI contrast that may offer high specificity for myelinated tissue. Existing ihMT and pulsed MT sequences often use separate radiofrequency pulses for saturation and signal excitation. This study investigates the use of nonselective multiband radiofrequency pulses for simultaneous off-resonance saturation and on-resonance excitation specifically for generation of ihMT contrast within rapid steady-state pulse sequences. Theory and Methods: A matrix-based signal modeling approach was developed and applied for both balanced steady state free precession and spoiled gradient echo sequences, accounting specifically for multiband pulses. Phantom experiments were performed using a combination of balanced steady state free precession and spoiled gradient echo sequences, and compared with model fits. A human brain imaging exam was performed using balanced steady state free precession sequences to demonstrate the achieved contrast. Results: A simple signal model derived assuming instantaneous radiofrequency pulses was shown to agree well with full integration of the governing equations and provided fits to phantom data for materials with strong ihMT contrast (PL161 root mean square error = 0.9%, and hair conditioner root mean square error = 2.4%). In vivo ihMT ratio images showed the expected white matter contrast that has been seen by other ihMT investigations, and the observed ihMT ratios corresponded well with predictions. Conclusions: ihMT contrast can be generated by integrating multiband radiofrequency pulses directly into both spoiled gradient echo and balanced steady state free precession sequences, and the presented signal modeling approach can be used to understand the acquired signals.
引用
收藏
页码:935 / 949
页数:15
相关论文
共 50 条
  • [11] Rapid Multicomponent Relaxometry in Steady State with Correction of Magnetization Transfer Effects
    Liu, Fang
    Block, Walter F.
    Kijowski, Richard
    Samsonov, Alexey
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (04) : 1423 - 1433
  • [12] Fast bound pool fraction mapping via steady-state magnetization transfer saturation using single-shot EPI
    Battiston, Marco
    Schneider, Torben
    Grussu, Francesco
    Yiannakas, Marios C.
    Prados, Ferran
    De Angelis, Floriana
    Wheeler-Kingshott, Claudia A. M. Gandini
    Samson, Rebecca S.
    MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (03) : 1025 - 1040
  • [13] Characterization of the cortical myeloarchitecture with inhomogeneous magnetization transfer imaging (ihMT)
    Munsch, Fanny
    Varma, Gopal
    Taso, Manuel
    Girard, Olivier
    Guidon, Arnaud
    Duhamel, Guillaume
    Alsop, David C.
    NEUROIMAGE, 2021, 225
  • [14] Optimum setting of binomial pulses for magnetization transfer contrast
    Davies, NP
    Summers, IR
    Vennart, W
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 2000, 11 (05): : 539 - 548
  • [15] Assessment of Magnetization Transfer Effects in Myocardial Tissue Using Balanced Steady-State Free Precession (bSSFP) Cine MRI
    Weber, Oliver M.
    Speier, Peter
    Scheffler, Klaus
    Bieri, Oliver
    MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (03) : 699 - 705
  • [16] Magnetization transfer contrast: Applications in brain imaging
    Ferrari, G
    Giovannini, G
    Torabi, S
    Gardini, M
    Monti, D
    RIVISTA DI NEURORADIOLOGIA, 2000, 13 (02): : 225 - 236
  • [17] Quantitative magnetization transfer imaging for non-contrast enhanced detection of myocardial fibrosis
    Lopez, Karina
    Neji, Radhouene
    Bustin, Aurelien
    Rashid, Imran
    Hajhosseiny, Reza
    Malik, Shaihan J.
    Teixeira, Rui Pedro A. G.
    Razavi, Reza
    Prieto, Claudia
    Roujol, Sebastien
    Botnar, Rene M.
    MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (04) : 2069 - 2083
  • [18] Optimization of inhomogeneous magnetization transfer (ihMT) MRI contrast for preclinical studies using dipolar relaxation time (T1D) filtering
    Prevost, V. H.
    Girard, O. M.
    Mchinda, S.
    Varma, G.
    Alsop, D. C.
    Duhamel, G.
    NMR IN BIOMEDICINE, 2017, 30 (06)
  • [19] Optimization of steady-state pulsed CEST imaging for amide proton transfer at 3T MRI
    Kim, Byungjai
    So, Seohee
    Park, Hyunwook
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (06) : 3616 - 3627
  • [20] Effect of magnetization transfer on the measurement of cerebral blood flow using steady-state arterial spin tagging approaches: A theoretical investigation
    McLaughlin, AC
    Ye, FQ
    Pekar, JJ
    Santha, AKS
    Frank, JA
    MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (04) : 501 - 510