Comparative study of test methods for reversed-phase columns for high-performance liquid chromatography

被引:170
作者
Claessens, HA
van Straten, MA
Cramers, CA
Jezierska, M
Buszewski, B
机构
[1] Eindhoven Univ Technol, Instrumental Anal Lab, Dept Chem Engn & Chem, NL-5600 MB Eindhoven, Netherlands
[2] Nicholas Copernicus Univ, Fac Chem, Dept Environm Chem, Torun, Poland
关键词
stationary phases; LC; reversed-phase columns; column classification;
D O I
10.1016/S0021-9673(98)00749-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Column selection in reversed-phase liquid chromatography (RPLC) is still not a straightforward process. A number of tests to characterise and classify RPLC columns have been suggested. Several tests are already applied in laboratory practice, while others are under development. The results of the various tests, however, are not always qualified to describe the properties of columns for RPLC. In this study different tests for RPLC-columns are studied and compared, viz. the Engelhardt, Tanaka, Galushko and Waiters tests. The column descriptors hydrophobicity and silanol activity are investigated in particular. The tests are studied using approximately 20 silica, alumina and polymer based C-8- and C-18-columns. Hydrophobicity data from the tests generally were good and interchangeable between the tests resulting in a column classification that is independent of the applied test. It appears that buffering of the eluent is mandatory for adequate testing of column silanol activity. In contrast with the high-quality hydrophobicity data, the silanol activity results of the various tests differ significantly. As a consequence column classification with respect to silanol activity depends considerably on the applied test method. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:135 / 156
页数:22
相关论文
共 64 条
[1]  
Abraham MH, 1997, J PHYS ORG CHEM, V10, P358, DOI 10.1002/(SICI)1099-1395(199705)10:5<358::AID-POC907>3.0.CO
[2]  
2-N
[3]   Determination of solute lipophilicity, as log P(octanol) and log P(alkane) using poly(styrene-divinylbenzene) and immobilised artificial membrane stationary phases in reversed-phase high-performance liquid chromatography [J].
Abraham, MH ;
Chadha, HS ;
Leitao, ARE ;
Mitchell, RC ;
Lambert, WJ ;
Kaliszan, R ;
Nasal, A ;
Haber, P .
JOURNAL OF CHROMATOGRAPHY A, 1997, 766 (1-2) :35-47
[4]   CHARACTERIZATION OF BONDED PHASES BY SOLID-STATE NMR-SPECTROSCOPY [J].
ALBERT, K ;
BAYER, E .
JOURNAL OF CHROMATOGRAPHY, 1991, 544 (1-2) :345-370
[5]   CHARACTERIZATION OF SILICA-BASED REVERSED-PHASE COLUMNS WITH RESPECT TO RETENTION SELECTIVITY - SOLVOPHOBIC EFFECTS [J].
ANTLE, PE ;
GOLDBERG, AP ;
SNYDER, LR .
JOURNAL OF CHROMATOGRAPHY, 1985, 321 (01) :1-32
[6]   Characterization of a range of alkyl-bonded silica HPLC stationary phases: Chromatographic behavior of neutral, acidic, and basic test solutes [J].
Barrett, DA ;
Brown, VA ;
Shaw, PN ;
Davies, MC ;
Ritchie, H ;
Ross, P .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1996, 34 (03) :146-156
[7]   Characterization of wide-pore reversed-phase columns for biopolymer separations .1. Single-parametric evaluation [J].
Bede, A ;
Rippel, G ;
Szepesy, L ;
Claessens, HA .
JOURNAL OF CHROMATOGRAPHY A, 1996, 728 (1-2) :179-188
[8]   SILICA - BACKBONE MATERIAL OF LIQUID-CHROMATOGRAPHIC COLUMN PACKINGS [J].
BERTHOD, A .
JOURNAL OF CHROMATOGRAPHY, 1991, 549 (1-2) :1-28
[9]   Influence of solvent effects on retention for a porous polymer sorbent in reversed phase liquid chromatography [J].
Bolliet, D ;
Poole, CF .
CHROMATOGRAPHIA, 1997, 46 (7-8) :381-398
[10]   Chemically bonded silica stationary phases: Synthesis, physicochemical characterization, and molecular mechanism of reversed phase HPLC retention [J].
Buszewski, B ;
GadzalaKopciuch, RM ;
Markuszewski, M ;
Kaliszan, R .
ANALYTICAL CHEMISTRY, 1997, 69 (16) :3277-3284