Pulsed-field ablation combined with ultrahigh-density mapping in patients undergoing catheter ablation for atrial fibrillation: Practical and electrophysiological considerations

被引:52
作者
Gunawardene, Melanie A. [1 ,2 ]
Schaeffer, Benjamin N. [1 ,2 ]
Jularic, Mario [1 ,2 ]
Eickholt, Christian [1 ,2 ]
Maurer, Tilman [1 ,2 ]
Akbulak, Ruken O. [1 ,2 ]
Flindt, Max [1 ,2 ]
Anwar, Omar [1 ,2 ]
Pape, Ulrich F. [2 ,3 ]
Maasberg, Sebastian [2 ,3 ]
Gessler, Nele [1 ,2 ,4 ,5 ]
Hartmann, Jens [1 ,2 ]
Willems, Stephan [1 ,2 ,4 ]
机构
[1] Asklepios Hosp St Georg, Dept Cardiol & Intens Care Med, Hamburg, Germany
[2] Semmelweis Univ, Fac Med, Budapest, Hungary
[3] Asklepios Hosp St Georg, Dept Internal Med, Hamburg, Germany
[4] DZHK German Ctr Cardiovasc Res, Partner Site Hamburg Kiel Lubeck, Berlin, Germany
[5] Asklepios Prores, Hamburg, Germany
关键词
atrial fibrillation; left posterior wall isolation; pulmonary vein isolation; pulsed-field ablation; ultrahigh-density mapping; PULMONARY VEIN ISOLATION; LESSONS;
D O I
10.1111/jce.15349
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Pulsed-field ablation (PFA) yields a novel ablation technology for atrial fibrillation (AF). PFA lesions promise to be highly durable, however clinical data on lesion characteristics are still limited. Objective This study sought to investigate PFA lesion creation with ultrahigh-density (UHDx) mapping. Methods Consecutive AF patients underwent PFA-based pulmonary vein isolation (PVI) using a multispline catheter (Farwave, Farapulse Inc.). Additional ablation, including left atrial posterior wall isolation (LAPWI) and mitral isthmus ablation (MI) were performed in a subset of persistent AF patients. The extent of PFA-lesions and decrease of LA-voltage were assessed with pre- and post PFA UHDx-mapping (Orion (TM) catheter and Rhythmia (TM) 3D-mapping system, Boston Scientific). Results In 20 patients, acute PVI was achieved in 80/80 PVs, LAPW isolation in 9/9 patients, MI ablation in 2/2 (procedure time: 123 +/- 21.6 min, fluoroscopy time: 19.2 +/- 5.5 min). UHDx-mapping subsequent to PVI revealed early PV-reconnection in five case (5/80, 6.25%). Gaps were located at the anterior-superior PV ostia and were successfully targeted with additional PFA. Repeat UHDx mapping after PFA revealed a significant decrease of voltage along the PV ostia (1.67 +/- 1.36 mV vs. 0.053 +/- 0.038 mV, p < .0001) with almost no complex electrogram-fractionation at the lesion border zones. PFA-catheter visualization within the mapping system was feasible in 17/19 (84.9%) patients and adequate in 92.9% of ablation sites. Conclusion For the first time illustrated by UHDx mapping, PFA creates wide antral circumferential lesions and homogenous LAPW isolation with depression of tissue voltage to a minimum. Although with a low incidence, early PV reconnection can still occur also in the setting of PFA.
引用
收藏
页码:345 / 356
页数:12
相关论文
共 26 条
[11]  
Hindricks G, 2021, EUR HEART J, V42, P546, DOI [10.1093/eurheartj/ehaa945, 10.1093/eurheartj/ehaa612]
[12]  
KAWAMURA I, 2021, EUROPACE, P1
[13]  
KAWAMURA I, HEART RHYTHM
[14]   Quantitative Analysis of Isolation Area and Rhythm Outcome in Patients With Paroxysmal Atrial Fibrillation After Circumferential Pulmonary Vein Antrum Isolation Using the Pace-and-Ablate Technique [J].
Kiuchi, Kunihiko ;
Kircher, Simon ;
Watanabe, Norikazu ;
Gaspar, Thomas ;
Rolf, Sascha ;
Arya, Arash ;
Piorkowski, Christopher ;
Hindricks, Gerhard ;
Sommer, Philipp .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2012, 5 (04) :667-675
[15]   Preclinical Evaluation of Pulsed Field Ablation Electrophysiological and Histological Assessment of Thoracic Vein Isolation [J].
Koruth, Jacob ;
Kuroki, Kenji ;
Iwasawa, Jin ;
Enomoto, Yoshinari ;
Viswanathan, Raju ;
Brose, Richard ;
Buck, Eric D. ;
Speltz, Molly ;
Dukkipati, Srinivas R. ;
Reddy, Vivek Y. .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2019, 12 (12)
[16]  
KORUTH JS, 2020, CIRC-ARRHYTHMIA ELEC, V13, DOI DOI 10.1161/CIRCEP.119.008303
[17]   Membrane Electroporation and Electropermeabilization: Mechanisms and Models [J].
Kotnik, Tadej ;
Rems, Lea ;
Tarek, Mounir ;
Miklavcic, Damijan .
ANNUAL REVIEW OF BIOPHYSICS, VOL 48, 2019, 48 :63-91
[18]   Recovered pulmonary vein conduction as a dominant factor for recurrent atrial tachyarrhythmias after complete circular isolation of the pulmonary veins -: Lessons from double lasso technique [J].
Ouyang, FF ;
Antz, M ;
Ernst, S ;
Hachiya, H ;
Mavrakis, H ;
Deger, FT ;
Schaumann, A ;
Chun, J ;
Falk, P ;
Hennig, D ;
Liu, XP ;
Bänsch, D ;
Kuck, KH .
CIRCULATION, 2005, 111 (02) :127-135
[19]   Pulsed Field Ablation of Paroxysmal Atrial Fibrillation 1-Year Outcomes of IMPULSE, PEFCAT, and PEFCAT II [J].
Reddy, Vivek Y. ;
Dukkipati, Srinivas R. ;
Neuzil, Petr ;
Anic, Ante ;
Petru, Jan ;
Funasako, Moritoshi ;
Cochet, Hubert ;
Minami, Kentaro ;
Breskovic, Toni ;
Sikiric, Ivan ;
Sediva, Lucie ;
Chovanec, Milan ;
Koruth, Jacob ;
Jais, Pierre .
JACC-CLINICAL ELECTROPHYSIOLOGY, 2021, 7 (05) :614-627
[20]   Pulsed Field Ablation in Patients With Persistent Atrial Fibrillation [J].
Reddy, Vivek Y. ;
Anic, Ante ;
Koruth, Jacob ;
Petru, Jan ;
Funasako, Moritoshi ;
Minami, Kentaro ;
Breskovic, Toni ;
Sikiric, Ivan ;
Dukkipati, Srinivas R. ;
Kawamura, Iwanari ;
Neuzil, Petr .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 76 (09) :1068-1080