Improved selectivity for the analysis of maternal serum and cord serum for polyfluoroalkyl chemicals

被引:164
作者
Kato, Kayoko [1 ]
Basden, Brian J. [1 ]
Needham, Larry L. [1 ]
Calafat, Antonia M. [1 ]
机构
[1] Ctr Dis Control & Prevent, Div Sci Lab, Natl Ctr Environm Hlth, Atlanta, GA 30341 USA
关键词
Polyfluoroalkyl chemicals; PFCs; On-line solid phase extraction; HPLC-MS/MS; Biomonitoring; PERFLUOROOCTANE SULFONATE PFOS; PERFLUORINATED CHEMICALS; NATIONAL-HEALTH; US POPULATION; FETAL-GROWTH; EXPOSURE; ACIDS;
D O I
10.1016/j.chroma.2010.10.051
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Perfluorooctane sulfonic acid (PFOS) and perfluorooctanoic acid, two of the most widely studied polyfluoroalkyl chemicals (PFCs), can cross the placenta. Therefore, data on the exposure to PFCs of the very young are needed to evaluate the potential health effects associated with such exposure. Human serum, especially serum collected from pregnant women and cord serum, may contain endogenous components that can interfere in the separation by high performance liquid chromatography (HPLC) of PFOS and another PFC of interest, perfluorohexane sulfonic acid (PFHxS), from other serum biomolecules. The presence of such interferences may prevent the adequate quantification of PFOS and PFHxS in cord serum or serum collected from pregnant women, and potentially hinder the assessment of gestational exposure to these important PFCs using biomonitoring. We have modified our on-line solid phase extraction-HPLC-isotope dilution-tandem mass spectrometry analytical method for measuring PFCs in serum and developed an approach that allows for the elimination of these potential interferences without compromising analytical sensitivity and throughput. The combination of acetonitrile as the HPLC mobile phase organic solvent and a Betasil C8 HPLC column provided the best separation of PFOS and PFHxS from interferent peaks. In addition to eliminating these interferences, the acetonitrile method has a shorter runtime and is more sensitive for most PFCs (limits of detection were 0.1 ng/mL except for PFOS (0.2 ng/mL)) than our previous method that used methanol for the HPLC separation. The present method should improve the precise and selective analysis of maternal and cord serum for PFCs. (C) 2010 Published by Elsevier B.V.
引用
收藏
页码:2133 / 2137
页数:5
相关论文
共 24 条
[11]   Maternal levels of perfluorinated chemicals and subfecundity [J].
Fei, Chunyuan ;
McLaughlin, Joseph K. ;
Lipworth, Loren ;
Olsen, Jorn .
HUMAN REPRODUCTION, 2009, 24 (05) :1200-1205
[12]   Perfluorinated compounds - Exposure assessment for the general population in western countries [J].
Fromme, Hermann ;
Tittlemier, Sheryl A. ;
Voelkel, Wolfgang ;
Wilhelm, Michael ;
Twardella, Dorothee .
INTERNATIONAL JOURNAL OF HYGIENE AND ENVIRONMENTAL HEALTH, 2009, 212 (03) :239-270
[13]   Perfluorooctane sulfonate (PFOS) and related perfluorinated compounds in human maternal and cord blood samples: Assessment of PFOS exposure in a susceptible population during pregnancy [J].
Inoue, K ;
Okada, F ;
Ito, R ;
Kato, S ;
Sasaki, S ;
Nakajima, S ;
Uno, A ;
Saijo, Y ;
Sata, F ;
Yoshimura, Y ;
Kishi, R ;
Nakazawa, H .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2004, 112 (11) :1204-1207
[14]   Analysis of blood spots for polyfluoroalkyl chemicals [J].
Kato, Kayoko ;
Wanigatunga, Amal A. ;
Needham, Larry L. ;
Calafat, Antonia M. .
ANALYTICA CHIMICA ACTA, 2009, 656 (1-2) :51-55
[15]   Determination of perfluorinated alkyl acid concentrations in human serum and milk standard reference materials [J].
Keller, Jennifer M. ;
Calafat, Antonia M. ;
Kato, Kayoko ;
Ellefson, Mark E. ;
Reagen, William K. ;
Strynar, Mark ;
O'Connell, Steven ;
Butt, Craig M. ;
Mabury, Scott A. ;
Small, Jeff ;
Muir, Derek C. G. ;
Leigh, Stefan D. ;
Schantz, Michele M. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 397 (02) :439-451
[16]   Fluorinated organics in the biosphere [J].
Key, BD ;
Howell, RD ;
Criddle, CS .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1997, 31 (09) :2445-2454
[17]   Measurement of 18 perfluorinated organic acids and amides in human serum using on-line solid-phase extraction [J].
Kuklenyik, Z ;
Needham, LL ;
Calafat, AM .
ANALYTICAL CHEMISTRY, 2005, 77 (18) :6085-6091
[18]   Perfluoroalkyl acids: A review of monitoring and toxicological findings [J].
Lau, Christopher ;
Anitole, Katherine ;
Hodes, Colette ;
Lai, David ;
Pfahles-Hutchens, Andrea ;
Seed, Jennifer .
TOXICOLOGICAL SCIENCES, 2007, 99 (02) :366-394
[19]   Accuracy and precision in the determination of perfluorinated chemicals in human blood verified by interlaboratory comparisons [J].
Lindstrom, Gunilla ;
Karrman, Anna ;
van Bavel, Bert .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (03) :394-400
[20]   Serum levels of perfluoroalkyl compounds in human maternal and umbilical cord blood samples [J].
Monroy, Rocio ;
Morrison, Katherine ;
Teo, Koon ;
Atkinson, Stephanie ;
Kubwabo, Cariton ;
Stewart, Brian ;
Foster, Warren G. .
ENVIRONMENTAL RESEARCH, 2008, 108 (01) :56-62