Fluoride release from a resin-modified glass-ionomer cement in a continuous-flow system: Effect of pH

被引:32
作者
Carey, CM [1 ]
Spencer, M [1 ]
Gove, RJ [1 ]
Eichmiller, FC [1 ]
机构
[1] NIST, Paffenbarger Res Ctr, Amer Dent Assoc Fdn, Gaithersburg, MD 20899 USA
关键词
fluoride; fluoride kinetics; glass-ionomer cement; fluoride release; controlled delivery systems;
D O I
10.1177/154405910308201013
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Fluoride is added to many dental restorative materials, including glass-ionomer cements, for the specific purpose of leaching fluoride into the surrounding tissues to provide secondary caries It inhibition. During the caries process, an acidic environment attacks the dental tissues as well as the glass-ionomer cement. We hypothesized that pH significantly affects the rate of release of fluoride from the glass-ionomer cement. A continuous-flow fluoride-measuring system that monitors the amount of fluoride released over time was used to determine the release of fluoride from a resin-modified glass-ionomer cement (KetacFil(R)). The results show that the release rate began with a fast burst of fluoride which quickly diminished to low levels in 3 days. Under neutral pH conditions, the rate of fluoride release at 72 firs was significantly slower than at pH 4.
引用
收藏
页码:829 / 832
页数:4
相关论文