Ceiling heat flux and downward received radiation heat flux induced by weak and relative strong fire plume in ventilation tunnels

被引:24
作者
Chen, Lei [1 ]
Tang, Fei [1 ]
Pang, Huanping [1 ]
机构
[1] Hefei Univ Technol, Sch Automot & Transportat Engn, Hefei 230009, Anhui, Peoples R China
关键词
Longitudinal ventilation; Tunnel fire; Ceiling jet; Heat flux; Radiation heat flux; EXTENSION LENGTHS BENEATH; LONGITUDINAL VENTILATION; MAXIMUM TEMPERATURE; IMPINGEMENT;
D O I
10.1016/j.applthermaleng.2020.114924
中图分类号
O414.1 [热力学];
学科分类号
摘要
The heat flux beneath the ceiling in tunnel fires is an important parameter, which have seldom been reported before in a longitudinal ventilation tunnel. A series of model tunnel experiments were conducted to investigate the ceiling heat flux and downward received radiation heat flux induced by weak and relative strong fire plume in ventilation tunnels. Overall, 96 repeatable test conditions were involved on different heat release rates, longitudinal ventilation velocities and the source-ceiling heights. The correlation for predicting the heat flux distribution beneath the tunnel ceiling is developed based on dimensionless analysis correlation, and the side-walls of the tunnel configuration present are concluded to increase the thermal heat feedback and further increase the ceiling heat flux. For the effect of longitudinal ventilation velocity, the position and value of the ceiling maximum heat flux will be varied with longitudinal ventilation velocity, and the source-ceiling height, the prediction model of the ceiling maximum heat flux under the effect of longitudinal ventilation was proposed. Meanwhile, with the increasing of the longitudinal ventilation velocity, the downward received radiation heat flux first increase and then keep relatively stable.
引用
收藏
页数:8
相关论文
共 28 条
  • [1] Alpert R.L., 1972, FIRE TECHNOL, V8, P181, DOI DOI 10.1007/BF02590543
  • [2] TURBULENT CEILING-JET INDUCED BY LARGE-SCALE FIRES
    ALPERT, RL
    [J]. COMBUSTION SCIENCE AND TECHNOLOGY, 1975, 11 (5-6) : 197 - 213
  • [3] Experimental study on the maximum temperature and flame extension length driven by strong plume in a longitudinal ventilated tunnel
    Chen, Longfei
    Du, Sheng
    Zhang, Yuchun
    Xie, Wei
    Zhang, Kejian
    [J]. EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2019, 101 : 296 - 303
  • [4] DILLON SE, 1998, NISTGCR98756
  • [5] An integral model for turbulent flame radial lengths under a ceiling
    Ding, Haiwen
    Quintiere, James G.
    [J]. FIRE SAFETY JOURNAL, 2012, 52 : 25 - 33
  • [6] Influence of ambient pressure on critical ventilation velocity and backlayering distance of thermal driven smoke in tunnels with longitudinal ventilation
    Guo, Fangyi
    Gao, Zihe
    Wan, Huaxian
    Ji, Jie
    Yu, Longxing
    Ding, Long
    [J]. INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2019, 145
  • [7] Hasemi Y, 1995, P AS, P51
  • [8] THE CONTRIBUTION OF FLAMES UNDER CEILINGS TO FIRE SPREAD IN COMPARTMENTS
    HINKLEY, PL
    WRAIGHT, HGH
    THEOBALD, CR
    [J]. FIRE SAFETY JOURNAL, 1984, 7 (03) : 227 - 242
  • [9] Jurges W., 1924, BEIHEFTEZUM GESUNDH, V1
  • [10] Kokkala M., 1989, VTT Research Report 586