Central Corneal Thickness and Anterior Scleral Thickness in Korean Patients With Open-angle Glaucoma: An Anterior Segment Optical Coherence Tomography Study

被引:31
作者
Yoo, Chungkwon [1 ]
Eom, Young Sub [1 ]
Suh, Young-Woo [1 ]
Kim, Yong Yeon [1 ]
机构
[1] Korea Univ, Coll Med, Dept Ophthalmol, Seoul 152703, South Korea
关键词
anterior segment optical coherence tomography; central corneal thickness; glaucoma; scleral thickness; INTRAOCULAR-PRESSURE; ULTRASOUND PACHYMETRY; OCULAR HYPERTENSION; AFRICAN-AMERICANS; TENSION GLAUCOMA; NERVE HEAD; EYE; POPULATION; CHINESE; BIOMICROSCOPY;
D O I
10.1097/IJG.0b013e3181dde051
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the correlation between central corneal thickness (CCT) and anterior scleral thickness (AST) in Korean patients with normal tension glaucoma (NTG) and primary open angle glaucoma (POAG). Patients and Methods: Consecutive patients with POAG, NTG, and normal individuals were recruited. Anterior segment optical coherence tomography (AS-OCT, Visante) was used to measure CCT and AST. The AST was measured 2mm posterior to the scleral spur in the temporal meridian. Statistical analysis of the data included ANOVA and Pearson correlation analysis. Results: One hundred and eight participants (36 with NTG, 35 with POAG, and 37 normal individuals) were enrolled. The CCT (NTG 514.81 + 25.03 mu m; POAG 534.43 + 34.79 mu m; controls 536.70 + 32.11 mu m) was found to be thinner in patients with NTG compared with POAG and the control eyes (P = 0.023; P = 0.009). The AST (NTG 738.53 + 53.63 mu m; POAG 771.86 + 53.75 mu m; controls 783.62 perpendicular to 57.03 mu m) was thinner in the patients with NTG compared with POAG and the normal controls (P = 0.032; P = 0.002). No significant difference in AST was found among the POAG and control eyes (P = 0.636). A correlation between CCT and AST was found only among the patients with NTG (r = 0.469, P = 0.004). However, no correlation was observed between CCT and AST in patients with POAG and controls. Conclusions: Anterior scleral thickness was correlated with CCT in the NTG group, but this correlation was not observed among the POAG or control groups.
引用
收藏
页码:95 / 99
页数:5
相关论文
共 30 条
[1]   Central corneal thickness of Caucasians, Chinese, Hispanics, Filipinos, African Americans, and Japanese in a glaucoma clinic [J].
Aghaian, E ;
Choe, JE ;
Lin, S ;
Stamper, RL .
OPHTHALMOLOGY, 2004, 111 (12) :2211-2219
[2]   Ciliary body thickness and refractive error in children [J].
Bailey, Melissa D. ;
Sinnott, Loraine T. ;
Mutti, Donald O. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (10) :4353-4360
[3]   Central corneal thickness measurement with a retinal optical coherence tomography device versus standard ultrasonic pachymetry [J].
Bechmann, M ;
Thiel, MJ ;
Neubauer, AS ;
Ullrich, S ;
Ludwig, K ;
Kenyon, KR ;
Ulbig, MW .
CORNEA, 2001, 20 (01) :50-54
[4]   The optic nerve head as a biomechanical structure: a new paradigm for understanding the role of IOP-related stress and strain in the pathophysiology of glaucomatous optic nerve head damage [J].
Burgoyne, CF ;
Downs, JC ;
Bellezza, AJ ;
Suh, JKF ;
Hart, RT .
PROGRESS IN RETINAL AND EYE RESEARCH, 2005, 24 (01) :39-73
[5]   Corneal thickness and intraocular pressure in a nonglaucomatous Burmese population - The meiktila eye study [J].
Casson, Robert J. ;
Abraham, Lekha M. ;
Newland, Henry S. ;
Muecke, James ;
Sullivan, Thomas ;
Selva, Dinesh ;
Aung, Than .
ARCHIVES OF OPHTHALMOLOGY, 2008, 126 (07) :981-985
[6]  
Copt RP, 1999, ARCH OPHTHALMOL-CHIC, V117, P14
[7]   Comparison of anterior segment optical coherence tomography and ultrasound biomicroscopy for assessment of the anterior segment [J].
Dada, Tanuj ;
Sihota, Ramanjit ;
Gadia, Ritu ;
Aggarwal, Anand ;
Mandal, Subrata ;
Gupta, Viney .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (05) :837-840
[8]   Human corneal thickness and its impact on intraocular pressure measures: A review and meta-analysis approach [J].
Doughty, MJ ;
Zaman, ML .
SURVEY OF OPHTHALMOLOGY, 2000, 44 (05) :367-408
[9]  
EHLERS N, 1974, ACTA OPHTHALMOL, V52, P740
[10]  
Gordon MO, 2002, ARCH OPHTHALMOL-CHIC, V120, P714