Comparison of Maximum-Likelihood List-Mode Reconstruction Algorithms in PET

被引:0
作者
Brinks, Ralph [1 ]
Schretter, Colas [2 ]
Meyer, Carsten [1 ]
机构
[1] Philips Res Labs Europe, Aachen, Germany
[2] Univ Libre Bruxelles, Brussels, Belgium
来源
2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6 | 2006年
关键词
Positron-Emission-Tomography; PET; List-Mode Reconstruction; Maximum-Likelihood Estimation; Ordered Subset Expectation Maximization; Raytracer; Jaszczak Phantom;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this work we compare images obtained from different list-mode reconstruction algorithms for PET data. Our analysis is based on list-mode data generated from a Geant4 simulation of the Jaszczak phantom. The first issue addressed is the influence of the raytracer used during reconstruction on the quality of the resulting images. We find that the Wu anti-aliased raytracer leads to better images than the Siddon algorithm at the expense of higher computational effort. The second question concerns a comparison of various modifications of the OSEM list-mode reconstruction algorithm. Here the convergent variant COSEM yields slightly better results at costs of much higher computational effort. However, the newer Enhanced COSEM does not need that effort to produce a similar image.
引用
收藏
页码:2801 / 2803
页数:3
相关论文
共 6 条
  • [1] Geant4 developments and applications
    Allison, J
    Amako, K
    Apostolakis, J
    Araujo, H
    Dubois, PA
    Asai, M
    Barrand, G
    Capra, R
    Chauvie, S
    Chytracek, R
    Cirrone, GAP
    Cooperman, G
    Cosmo, G
    Cuttone, G
    Daquino, GG
    Donszelmann, M
    Dressel, M
    Folger, G
    Foppiano, F
    Generowicz, J
    Grichine, V
    Guatelli, S
    Gumplinger, P
    Heikkinen, A
    Hrivnacova, I
    Howard, A
    Incerti, S
    Ivanchenko, V
    Johnson, T
    Jones, F
    Koi, T
    Kokoulin, R
    Kossov, M
    Kurashige, H
    Lara, V
    Larsson, S
    Lei, F
    Link, O
    Longo, F
    Maire, M
    Mantero, A
    Mascialino, B
    McLaren, I
    Lorenzo, PM
    Minamimoto, K
    Murakami, K
    Nieminen, P
    Pandola, L
    Parlati, S
    Peralta, L
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (01) : 270 - 278
  • [2] An accelerated convergent ordered subsets algorithm for emission tomography
    Hsiao, IT
    Rangarajan, A
    Khurd, P
    Gindi, G
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (11) : 2145 - 2156
  • [3] A provably convergent OS-EM like reconstruction algorithm for emission tomography
    Hsiao, IT
    Rangarajan, A
    Gindi, G
    [J]. MEDICAL IMAGING 2002: IMAGE PROCESSING, VOL 1-3, 2002, 4684 : 10 - 19
  • [4] Statistical list-mode image reconstruction for the high resolution research tomograph
    Rahmim, A
    Lenox, M
    Reader, AJ
    Michel, C
    Burbar, Z
    Ruth, TJ
    Sossi, V
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (18) : 4239 - 4258
  • [5] FAST CALCULATION OF THE EXACT RADIOLOGICAL PATH FOR A 3-DIMENSIONAL CT ARRAY
    SIDDON, RL
    [J]. MEDICAL PHYSICS, 1985, 12 (02) : 252 - 255
  • [6] WU XL, 1991, COMP GRAPH, V25, P143, DOI 10.1145/127719.122734