Degree of Flocculation and Interparticles Charges of Conditioned Municipal Activated Sludge using Mixed Polymers

被引:10
作者
Al-Dawery, Salam K. [1 ]
机构
[1] Univ Nizwa, Nizwa, Oman
来源
JOURNAL OF MACROMOLECULAR SCIENCE PART B-PHYSICS | 2017年 / 56卷 / 08期
关键词
activated sludge; polymers; flocculants; interparticle charges; SEWAGE SLUDGES; POLYELECTROLYTE; SUSPENSIONS; RHEOLOGY; BEHAVIOR;
D O I
10.1080/00222348.2017.1356131
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
The present research work focuses on a new conditioning and flocculation mechanism of municipal fresh activated sludge using a dual polymer system combining cationic and anionic polyelectrolytes. Various pairs of three different types of polyelectrolytes, low molecular weight cationic polyacrylamide (CPAM-10), high molecular weight cationic polyacrylamide (CPAM- 80) and an anionic polyacrylamide (APAM-30), were selected, being used either individually or as cationic-anionic pairs. The results of use of the dual systems indicated that using mixed polymers for conditioning gave lower turbidity with better settling when compared to that of using individual pure polymers. The mixed polymers improved the sludge volume index (SVI) by 62%. The zeta potentials of the supernatant and solid-like samples of conditioned activated sludge were measured. Slight increases in zeta potential, from -12 to -9, of the mixed polymers for all supernatants were observed. On the other hand, zeta measurements showed that the sludge solid-like particles retained their negative charges despite the addition of the individual cationic polymers in the mixture. This phenomenon was explained in terms of the addition of the polyelectrolytes attracting, primarily, the carboxylic groups of the fine suspended sludge particles, while hydrogen bonds between the larger sludge particles resulted in attraction in accordance with the Van der Waals mechanism, and both attractions caused an immediate dewatering that led to flocculation, but with low compactness. As a result of retaining negative charges on the large sludge particles, dissolved metals were partially attracted, causing reduction in conductivities of the supernatants of 10% to 15% for all pairs. Rheological tests showed that the formed flocs had low shear stress resistances, ranging between 0.2 and 0.4 Pa, and weak flocs strength.
引用
收藏
页码:578 / 594
页数:17
相关论文
共 29 条
[1]  
Abu-Jdayil Basim, 2010, Journal of Water Resource and Protection, V2, P1, DOI 10.4236/jwarp.2010.21001
[2]  
Al-Dawery S. K., 2014, INT J MED DENT PHARM, V8, P285
[4]  
Al-Dawery SK, 2015, J ENG SCI TECHNOL, V10, P692
[5]  
[Anonymous], 2006, STANDARD METHODS EXA, DOI DOI 10.5860/CHOICE.37-2792
[6]   Pre-treatment, measurement execution procedure and waste characteristics in the rheology of sewage sludges and the digested organic fraction of municipal solid wastes [J].
Battistoni, P .
WATER SCIENCE AND TECHNOLOGY, 1997, 36 (11) :33-41
[7]   The rheological behaviour of anaerobic digested sludge [J].
Baudez, J. C. ;
Markis, F. ;
Eshtiaghi, N. ;
Slatter, P. .
WATER RESEARCH, 2011, 45 (17) :5675-5680
[8]   Rheology of aging, concentrated, polymeric suspensions: Application to pasty sewage sludges [J].
Baudez, JC ;
Coussot, P .
JOURNAL OF RHEOLOGY, 2001, 45 (05) :1123-1139
[9]   Rheological characteristics of the cationic polyelectrolyte flocculated wastewater sludge [J].
Chen, BH ;
Lee, SJ ;
Lee, DJ .
WATER RESEARCH, 2005, 39 (18) :4429-4435
[10]   COLLAGEN DISPERSIONS FOR LIQUID-SOLID SEPARATIONS IN WATER-TREATMENT AND SLUDGE DEWATERING [J].
DAVIS, JF ;
MAFFIA, GJ .
SEPARATIONS TECHNOLOGY, 1995, 5 (03) :147-152