Wind-tunnel experiments on atmospheric heavy gas dispersion: Metrological aspects

被引:8
作者
Vidali, Cristina [1 ,2 ]
Marro, Massimo [1 ]
Correia, Horacio [1 ]
Gostiaux, Louis [1 ]
Jallais, Simon [2 ]
Houssin, Deborah [2 ]
Vyazmina, Elena [2 ]
Salizzoni, Pietro [1 ]
机构
[1] Univ Lyon, Univ Claude Bernard Lyon 1, CNRS, Ecole Cent Lyon, F-69130 Ecully, France
[2] Air Liquide Paris Res & Dev Ctr, Paris Innovat Campus,1 Chemin Porte Loges,Loge, Jouy En Josas, France
关键词
Calibration; Hot-wire anemometry; Flame ionisation detector; Wind tunnel; Heavy gas dispersion; HOT-WIRE; TURBULENT FLUXES; LINE SOURCE; FIELD; AIR; DIFFUSION; BEHAVIOR; VELOCITY; PLUMES; FLOWS;
D O I
10.1016/j.expthermflusci.2021.110495
中图分类号
O414.1 [热力学];
学科分类号
摘要
We propose a new experimental protocol to investigate the atmospheric dispersion of a dense gas in wind-tunnel experiments. Simultaneous measurements of concentration and velocity are performed by coupling a flame ionisation detector (FID) and a hot-wire anemometer (HWA), whose probes are located sufficiently close to each other so that the respective measurements correspond to a same sampling volume. The heavy gas emission consists in a mixture of air, carbon dioxide, and ethane. Carbon dioxide is used as a buoyant agent, and ethane is used as a tracer, its concentration being detected by the FID. In this context, the main metrological issue of the setup concerns the response of the FID and the HWA to different proportions of the two gases in the mixture. Notably, the presence of carbon dioxide affects the linear response of the FID, which can attain a saturation level, as well as the response of the HWA, due to the varying density of the gas. This can be compensated by determining a non-linear calibration curve of the FID, which is used to determine the instantaneous fluid density, and to apply a time-dependent correction to the HWA response. To analyse the performances of the coupled HWA-FID system we realised wind-tunnel experiments of tracer dispersion in a turbulent boundary layer. The estimate of mass fluxes through different sections downwind the source enlightens the reliability of the experimental results, and show that the measurements within a negatively buoyant gas plume are as accurate as those within a passive scalar plume.
引用
收藏
页数:9
相关论文
共 43 条
[1]  
Abbiss J. B., 1974, Optics and Laser Technology, V6, P249, DOI 10.1016/0030-3992(74)90006-1
[2]   A convection heat transfer correlation for a binary air-helium mixture at low reynolds number [J].
Banerjee, Arindam ;
Andrews, Malcolm J. .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2007, 129 (11) :1494-1505
[3]  
Briggs G, 1998, NATO CHAL M, V22, P509
[4]   Dense gas vertical diffusion over rough surfaces: results of wind-tunnel studies [J].
Briggs, GA ;
Britter, RE ;
Hanna, SR ;
Havens, JA ;
Robins, AG ;
Snyder, WH .
ATMOSPHERIC ENVIRONMENT, 2001, 35 (13) :2265-2284
[5]   FLUID MODELING OF DENSE GAS DISPERSION OVER A RAMP [J].
BRITTER, RE ;
SNYDER, WH .
JOURNAL OF HAZARDOUS MATERIALS, 1988, 18 (01) :37-67
[6]  
BRITTER RE, 1989, ANNU REV FLUID MECH, V21, P317
[7]  
Bruun H. H., 1996, Meas. Sci. Technol, V7, P024, DOI DOI 10.1088/0957-0233/7/10/024
[8]  
C. Ltd, 2006, FRR400 FAST RESPONSE
[9]   Wind tunnel measurements of pollutant turbulent fluxes in urban intersections [J].
Carpentieri, Matteo ;
Hayden, Paul ;
Robins, Alan G. .
ATMOSPHERIC ENVIRONMENT, 2012, 46 :669-674
[10]   Tracer Flux Balance at an Urban Canyon Intersection [J].
Carpentieri, Matteo ;
Robins, Alan G. .
BOUNDARY-LAYER METEOROLOGY, 2010, 135 (02) :229-242