Evaluation of a semi-automated von Willebrand factor multimer assay, the Hydragel 5 von Willebrand multimer, by two European Centers

被引:33
作者
Bowyer, Annette E. [1 ]
Goodfellow, Karen J. [1 ]
Seidel, Holger [2 ]
Westhofen, Philipp [2 ]
Stufano, Francesca [3 ,4 ]
Goodeve, Anne [5 ]
Kitchen, Stephen [3 ,4 ]
Makris, Michael [1 ]
机构
[1] Sheffield Haemophilia & Thrombosis Ctr, Dept Coagulat, Sheffield, S Yorkshire, England
[2] Ctr Blutgerinnungsstorungen & Transfus Med, Bonn, Germany
[3] Fdn IRCCS Ca Granda Osped Maggiore Policlin, Angelo Bianchi Bonomi Hemophilia & Thrombosis Ctr, Milan, Italy
[4] Luigi Villa Fdn, Milan, Italy
[5] Univ Sheffield, Med Sch, Dept Infect Immun & Cardiovasc Dis, Sheffield, S Yorkshire, England
关键词
densitometry; HMWM Hydragel; multimer; VWD; VWF; VONWILLEBRAND-FACTOR MULTIMERS; DISEASE; CLASSIFICATION; MANAGEMENT; DIAGNOSIS;
D O I
10.1002/rth2.12141
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The phenotypic diagnosis of von Willebrand disease (VWD) is a multi-step process with classification dependent on the quantification of von Willebrand factor (VWF) multimeric structure. VWF multimer analysis is a technically challenging, lengthy and non-standardised assay, usually performed in specialist laboratories. Recently, a new semi-automated multimer assay, the Hydragel 5 von Willebrand multimers (H5VWM) has become available. Objectives: This study, performed in two European centres, compared existing in-house multimer assays to the H5VWM in individuals with and without VWD. Results: Overall agreement of 91.1% was observed in 74 individuals with normal VWF levels, 57 patients grouped as type 1 VWD, 33 type 2A, 16 type 2B, 28 type 2M, 11 type 2N. Patients tested following Desmopressin or VWF concentrate, with thrombotic thrombocytopenic purpura and acquired von Willebrand syndrome were also evaluated. Many of the discrepancies between methods were in patients with genetic mutations linked to more than one type of VWD including p.R1374C/H and p.R1315C. Quantifiable multimer results were available within one working day. Densitometry improved the interpretation of the multimers with slight structural variations that were not apparent by visual inspection of the in-house method. Conclusions: 5VWM was a rapid, sensitive, standardised assay which used existing technology and could be included as an initial screen of VWF multimers in a VWD diagnostic algorithm in conjunction with traditional multimer analysis.
引用
收藏
页码:790 / 799
页数:10
相关论文
共 27 条
[1]   Haemate® P/Humate-P® for the treatment of von Willebrand disease: considerations for use and clinical experience [J].
Auerswald, G. ;
Kreuz, W. .
HAEMOPHILIA, 2008, 14 :39-46
[2]   Platelet-dependent von Willebrand factor activity. Nomenclature and methodology: communication from the SSC of the ISTH [J].
Bodo, I. ;
Eikenboom, J. ;
Montgomery, R. ;
Patzke, J. ;
Schneppenheim, R. ;
Di Paola, J. .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2015, 13 (07) :1345-1350
[3]   Detailed von Willebrand factor multimer analysis in patients with von Willebrand disease in the European study, molecular and clinical markers for the diagnosis and management of type 1 von Willebrand disease (MCMDM-1VWD) [J].
Budde, U. ;
Schneppenheim, R. ;
Eikenboom, J. . ;
Goodeve, A. ;
Will, K. ;
Drewke, E. ;
Castaman, G. ;
Rodeghiero, F. ;
Federici, A. B. ;
Batlle, J. . ;
Perez, A. ;
Meyer, D. ;
Mazurier, C. ;
Goudemand, J. ;
Ingerslev, J. ;
Habart, D. ;
Vorlova, Z. ;
Holmberg, L. ;
Lethagen, S. ;
Pasi, J. ;
Hill, F. ;
Peake, I. .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2008, 6 (05) :762-771
[4]  
BUDDE U, 1990, THROMB HAEMOSTASIS, V63, P312
[5]   Identifying type Vicenza von Willebrand disease [J].
Casonato, A ;
Pontara, E ;
Sartorello, F ;
Cattini, MG ;
Gallinaro, L ;
Bertomoro, A ;
Rosato, A ;
Padrini, R ;
Pagnan, A .
JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 2006, 147 (02) :96-102
[6]   Type 2M von Willebrand disease variant characterized by abnormal von Willebrand factor multimerization [J].
Casonato, A ;
Pontara, E ;
Sartorello, F ;
Bertomoro, A ;
Durante, C ;
Girolami, A .
JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 2001, 137 (01) :70-76
[7]   ANALYSIS OF VONWILLEBRAND-FACTOR MULTIMERS USING A COMMERCIALLY AVAILABLE ENHANCED CHEMILUMINESCENCE KIT [J].
CUMMING, AM ;
WENSLEY, RT .
JOURNAL OF CLINICAL PATHOLOGY, 1993, 46 (05) :470-473
[8]   ANALYSIS OF THE COMPLEXITY OF THE MULTIMERIC STRUCTURE OF FACTOR-VIII RELATED ANTIGEN VONWILLEBRAND PROTEIN USING A MODIFIED ELECTROPHORETIC TECHNIQUE [J].
ENAYAT, MS ;
HILL, FGH .
JOURNAL OF CLINICAL PATHOLOGY, 1983, 36 (08) :915-919
[9]   Evaluation of a new commercial von Willebrand factor multimer assay [J].
Favaloro, E. J. ;
Oliver, S. .
HAEMOPHILIA, 2017, 23 (04) :E373-E377
[10]   Differential identification of a rare form of platelet-type (pseudo-) von Willebrand disease (VWD) from Type 2B VWD using a simplified ristocetin-induced-platelet-agglutination mixing assay and confirmed by genetic analysis [J].
Favaloro, Emmanuel J. ;
Patterson, David ;
Denholm, Anna ;
Mead, Scott ;
Gilbert, Ann ;
Collins, Anne ;
Estell, Jane ;
George, Peter M. ;
Smith, Mark P. .
BRITISH JOURNAL OF HAEMATOLOGY, 2007, 139 (04) :623-626