Performance analysis of a rooftop, air-to-air heat pump working with CO2

被引:20
作者
Calabrese, Nicolandrea [1 ]
Mastrullo, Rita [2 ]
Mauro, Alfonso William [2 ]
Rovella, Paola [3 ]
Tammaro, Marcello [2 ]
机构
[1] ENEA, Inst Thermal Fluid Dynam, I-00123 Rome, Italy
[2] Univ Naples Federico II, Dept Ind Engn, I-80125 Naples, Italy
[3] Univ Calabria, DIMEG, I-87036 Arcavacata Di Rende, CS, Italy
关键词
Roof-top system; Heat pump; CO2; Air-to-air; Performance assessment; CARBON-DIOXIDE; REFRIGERANT; SYSTEMS; CYCLE;
D O I
10.1016/j.applthermaleng.2014.10.057
中图分类号
O414.1 [热力学];
学科分类号
摘要
The air-conditioning sector for large buildings and shopping centers is developing a growing interest in rooftop heat pumps due to their easy installation. Instead of the application of HFC refrigerants, carbon dioxide (CO2) could be an interesting perspective in this sector for environmental reasons. This work presents new performance data of an air-to-air heat pump roof-top system working with a trans-critical carbon dioxide cycle during the heating season. In particular, the experimental results showed how the heating power and the coefficient of performance are affected by the air temperature at the inlet of the gas cooler and by part load working conditions. A thermodynamic analysis pointed out the direct and indirect effects of fans speed and air flow temperatures on the performance, defining a performance map and the optimal range of application of such systems. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1046 / 1054
页数:9
相关论文
共 24 条
[1]  
[Anonymous], 2005, RESIDENTIAL COMMERIC
[2]  
[Anonymous], ANN EN REV 2011
[3]   Transcritical carbon dioxide heat pump systems: A review [J].
Austin, Brian T. ;
Sumathy, K. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2011, 15 (08) :4013-4029
[4]   Optimal control of the gas-cooler pressure of a CO2 heat pump using EEV opening and outdoor fan speed in the cooling mode [J].
Baek, Changhyun ;
Heo, Jaehyeok ;
Jung, Jongho ;
Cho, Honghyun ;
Kim, Yongchan .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2013, 36 (04) :1276-1284
[5]  
Bejan A., 1997, Advanced Engineering Thermodynamics, Vsecond
[6]   Experimental performance evaluation for a carbon dioxide light commercial cooling application under transcritical and subcritical conditions [J].
Boccardi, G. ;
Calabrese, N. ;
Celata, G. P. ;
Mastrullo, R. ;
Mauro, A. W. ;
Perrone, A. ;
Trinchieri, R. .
APPLIED THERMAL ENGINEERING, 2013, 54 (02) :528-535
[7]   Ozone depletion and global warming: Case for the use of natural refrigerant - a review [J].
Bolaji, B. O. ;
Huan, Z. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2013, 18 :49-54
[8]  
Brown JS, 2002, INT J REFRIG, V25, P19
[9]   Design and simulation of a heat pump for simultaneous heating and cooling using HFC or CO2 as a working fluid [J].
Byrne, Paul ;
Miriel, Jacques ;
Lenat, Yves .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2009, 32 (07) :1711-1723
[10]   Two-stage transcritical carbon dioxide cycle optimisation: A theoretical and experimental analysis [J].
Cavallini, A ;
Cecchinato, L ;
Corradi, M ;
Fornasieri, E ;
Zilio, C .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (08) :1274-1283