Flexor tendon injuries following locked volar plating of distal radius fractures

被引:94
作者
Cross, Andrew W. [1 ]
Schmidt, Christopher C. [1 ]
机构
[1] Allegheny Gen Hosp, Allegheny Hand Ctr, Pittsburgh, PA 15212 USA
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 2008年 / 33A卷 / 02期
关键词
complications; distal radius; flexor tendon rupture; fracture; volar plate;
D O I
10.1016/j.jhsa.2007.11.011
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We present 2 cases showing that flexor pollicis longus and flexor digitorum profundus index injury can occur after placement of 2 commonly used locked volar plates. In contrast with the literature, the radii healed in an anatomic position without plate lift-off. The patients presented 6 and 8 months after surgery with new onset of radial wrist pain and tenderness at the site of the plate and absence or weakness of the flexor pollicis longus. In both cases, the plate was positioned anterior to the distal radial rim on the lateral radiograph. We suggest close follow-up of all fractures in which the distal end of the plate is anterior to the radial rim and removal of hardware if symptoms suggest tendon irritation.
引用
收藏
页码:164 / 167
页数:4
相关论文
共 17 条
[1]   Rupture of flexor pollicis longus tendon - A complication of volar plating of the distal radius [J].
Bell, JSP ;
Wollstein, R ;
Citron, ND .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (02) :225-226
[2]   Volar versus dorsal locking plates with and without radial styloid locking plates for the fixation of dorsally comminuted distal radius fractures: A biomechanical study in cadavers [J].
Blythe, Murray ;
Stoffel, Karl ;
Jarrett, Paul ;
Kuster, Markus .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (10) :1587-1593
[3]   Volar fixed-angle plating of distal radius extension fractures: influence of plate position on secondary loss of reduction - A biomechanic study in a cadaveric model [J].
Drobetz, H ;
Bryant, AL ;
Pokorny, T ;
Spitaler, R ;
Leixnering, M ;
Jupiter, JB .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (04) :615-622
[4]   Biornechanics and biology of plate fixation of distal radius fractures [J].
Freeland, AE ;
Luber, KT .
HAND CLINICS, 2005, 21 (03) :329-+
[5]   Biomechanical comparison of fixed-angle volar plate versus fixed-angle volar plate plus fragment-specific fixation in a cadaveric distal radius fracture model [J].
Grindel, Steven I. ;
Wang, Mei ;
Gerlach, Matthew ;
McGrady, Linda M. ;
Brown, Susan .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2007, 32A (02) :194-199
[6]   Complications of the AO/ASIF titanium distal radius plate system (π plate) in internal fixation of the distal radius:: A brief report [J].
Kambouroglou, GK ;
Axelrod, TS .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1998, 23A (04) :737-741
[7]   Rupture of the flexor pollicis longus tendon after volar fixed-angle plating of a distal radius fracture: A case report [J].
Klug, Raymond A. ;
Press, Cyrus M. ;
Gonzalez, Mark H. .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2007, 32A (07) :984-988
[8]   Volar fixation for dorsally angulated extra-articular fractures of the distal radius: A biomechanical study [J].
Koh, Shukuki ;
Morris, Randal P. ;
Patterson, Rita A. ;
Kearney, J. Patrick ;
Buford, William L., Jr. ;
Viegas, Steven F. .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (05) :771-779
[9]   A biomechanical comparison of two volar locked plates in a dorsally unstable distal radius fracture model [J].
Liporace, Frank Anthony ;
Kubiak, Erik N. ;
Jeong, Gerard K. ;
Iesaka, Kazuho ;
Egol, Kenneth A. ;
Koval, Kenneth J. .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2006, 61 (03) :668-672
[10]  
Lowry K J, 2000, Am J Orthop (Belle Mead NJ), V29, P789