A transfer function model of lighting heat dissipation for detecting time-delay effect and dynamic cooling demand during the real-time operation of buildings

被引:5
作者
Li, Ruonan [1 ]
Zhang, Jili [1 ]
机构
[1] Dalian Univ Technol, Fac Infrastruct Engn, Dalian 116024, Peoples R China
关键词
Real-time heat dissipation; Lighting; Transfer function model; Nearly adiabatic test chamber; EMITTING-DIODES; FLUORESCENT; IMPACTS; LOADS;
D O I
10.1016/j.enbuild.2021.111538
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Monitoring real-time heat dissipation of lighting, a major indoor heat source, is essential for determining the dynamic cooling demand of buildings, and it provides a reliable basis for sizing air-conditioning sys-tems and saving energy. Contemporary models cannot be used to obtain the accurate real-time heat dis-sipation of lighting or the time-delay effect, because of which these models have critical limitations in precisely detecting dynamic cooling demand of buildings. To address this problem, a transfer function model is proposed for calculating the real-time heat dissipation of lighting in this paper. First, the model structure is determined according to the energy conservation law, heat transfer principles, and so on. Second, an experiment is conducted using a nearly adiabatic test chamber. Third, parameter identifica-tion and order reduction analyses are performed, and the real-time heat dissipation model of lighting is determined as a third-order transfer function. Experimental data of the same and different types of lighting are employed to verify the proposed model, and the maximum mean absolute percentage error (MAPE) is 7.83%. Comparing with the fixed ratio method, the proposed transfer function model not only reduces MAPE by 66.05% within 1 h after lighting is turned on but also describes a time-delay effect in the stability of lighting heat dissipation. The results of this study exhibit the promising applicability for accu-rately determining the cooling demand of a building during real-time operation, thus improving the indoor thermal environment and reducing energy consumption. (c) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页数:17
相关论文
共 46 条
  • [1] Building energy metering and environmental monitoring - A state-of-the-art review and directions for future research
    Ahmad, Muhammad Waseem
    Mourshed, Monjur
    Mundow, David
    Sisinni, Mario
    Rezgui, Yacine
    [J]. ENERGY AND BUILDINGS, 2016, 120 : 85 - 102
  • [2] Effect of LED lighting on the cooling and heating loads in office buildings
    Ahn, Byung-Lip
    Jang, Cheol-Yong
    Leigh, Seung-Bok
    Yoo, Seunghwan
    Jeong, Hakgeun
    [J]. APPLIED ENERGY, 2014, 113 : 1484 - 1489
  • [3] American Society of Heating Refrigerating and Air Conditioning Engineers Inc, 2016, 9012016 ASHRAE
  • [4] [Anonymous], 2017, ENVIRON ENG
  • [5] [Anonymous], 1972, ASHRAE HDB FUND
  • [6] [Anonymous], 2015, Design standard for energy efficiency of public buildings GB 50189-2015
  • [7] [Anonymous], 2014, BUILDING ENERGY MONI
  • [8] Assessing the lighting systems flexibility for reducing and managing the power peaks in smart grids
    Beccali, Marco
    Bellia, Laura
    Fragliasso, Francesca
    Bonomolo, Marina
    Zizzo, Gaetano
    Spada, Gennaro
    [J]. APPLIED ENERGY, 2020, 268
  • [9] Chen S., 2015, SCI TOTAL ENVIRON
  • [10] Impacts of building geometry modeling methods on the simulation results of urban building energy models
    Chen, Yixing
    Hong, Tianzhen