Diagnosis of central serous chorioretinopathy by deep learning analysis of en face images of choroidal vasculature: A pilot study

被引:16
作者
Aoyama, Yukihiro [1 ]
Maruko, Ichiro [1 ]
Kawano, Taizo [1 ]
Yokoyama, Tatsuro [1 ]
Ogawa, Yuki [1 ]
Maruko, Ruka [1 ]
Iida, Tomohiro [1 ]
机构
[1] Tokyo Womens Med Univ, Dept Ophthalmol, Shinjuku Ku, Tokyo, Japan
关键词
PHOTODYNAMIC THERAPY; THICKNESS; EYES;
D O I
10.1371/journal.pone.0244469
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose To diagnose central serous chorioretinopathy (CSC) by deep learning (DL) analyses of en face images of the choroidal vasculature obtained by optical coherence tomography (OCT) and to analyze the regions of interest for the DL from heatmaps. Methods One-hundred eyes were studied; 53 eyes with CSC and 47 normal eyes. Volume scans of 12x12 mm square were obtained at the same time as the OCT angiographic (OCTA) scans (Plex Elite 9000 Swept-Source OCT(R), Zeiss). High-quality en face images of the choroidal vasculature of the segmentation slab of one-half of the subfoveal choroidal thickness were created for the analyses. The 100 en face images were divided into 80 for training and 20 for validation. Thus, we divided it into five groups of 20 eyes each, trained the remaining 80 eyes in each group, and then calculated the correct answer rate for each group by validation with 20 eyes. The Neural Network Console (NNC) developed by Sony and the Keras-Tensorflow backend developed by Google were used as the software for the classification with 16 layers of convolutional neural networks. The active region of the heatmap based on the feature quantity extracted by DL was also evaluated as the percentages with gradient-weighted class activation mapping implemented in Keras. Results The mean accuracy rate of the validation was 95% for NNC and 88% for Keras. This difference was not significant (P >0.1). The mean active region in the heatmap image was 12.5% in CSC eyes which was significantly lower than the 79.8% in normal eyes (P<0.01). Conclusions CSC can be automatically diagnosed by DL with high accuracy from en face images of the choroidal vasculature with different programs, convolutional layer structures, and small data sets. Heatmap analyses showed that the DL focused on the area occupied by the choroidal vessels and their uniformity. We conclude that DL can help in the diagnosis of CSC.
引用
收藏
页数:10
相关论文
共 41 条
[1]   Using Deep Learning and Transfer Learning to Accurately Diagnose Early-Onset Glaucoma From Macular Optical Coherence Tomography Images [J].
Asaoka, Ryo ;
Murata, Hiroshi ;
Hirasawa, Kazunori ;
Fujino, Yuri ;
Matsuura, Masato ;
Miki, Atsuya ;
Kanamoto, Takashi ;
Ikeda, Yoko ;
Mori, Kazuhiko ;
Iwase, Aiko ;
Shoji, Nobuyuki ;
Inoue, Kenji ;
Yamagami, Junkichi ;
Araie, Makoto .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2019, 198 :136-145
[2]   Automated Diagnosis of Plus Disease in Retinopathy of Prematurity Using Deep Convolutional Neural Networks [J].
Brown, James M. ;
Campbell, J. Peter ;
Beers, Andrew ;
Chang, Ken ;
Ostmo, Susan ;
Chan, R. V. Paul ;
Dy, Jennifer ;
Erdogmus, Deniz ;
Ioannidis, Stratis ;
Kalpathy-Cramer, Jayashree ;
Chiang, Michael F. .
JAMA OPHTHALMOLOGY, 2018, 136 (07) :803-810
[3]   Computer-aided recognition of myopic tilted optic disc using deep learning algorithms in fundus photography [J].
Cho, Baek Hwan ;
Lee, Young ;
Park, Kyung-Ah ;
Oh, Sei Yeul ;
Moon, Jong Hak ;
Lee, Ga-In ;
Noh, Hoon ;
Chung, Joon Kyo ;
Kang, Min Chae ;
Chung, Myung Jin .
BMC OPHTHALMOLOGY, 2020, 20 (01)
[4]   Factors Affecting Choroidal Vascular Density in Normal Eyes: Quantification Using En Face Swept-Source Optical Coherence Tomography [J].
Fujiwara, Atsushi ;
Morizane, Yuki ;
Hosokawa, Mio ;
Kimura, Shuhei ;
Kumase, Fumiaki ;
Shiode, Yusuke ;
Doi, Shinichiro ;
Hirano, Masayuki ;
Toshima, Shinji ;
Hosogi, Mika ;
Shiraga, Fumio .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2016, 170 :1-9
[5]   Automated Identification of Diabetic Retinopathy Using Deep Learning [J].
Gargeya, Rishab ;
Leng, Theodore .
OPHTHALMOLOGY, 2017, 124 (07) :962-969
[6]   Deep learning in ophthalmology: a review [J].
Grewal, Parampal S. ;
Oloumi, Faraz ;
Rubin, Uriel ;
Tennant, Matthew T. S. .
CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2018, 53 (04) :309-313
[7]  
Hassan Bilal, 2018, 2018 2nd IEEE Advanced Information Management, Communicates, Electronic and Automation Control Conference (IMCEC). Proceedings, P824, DOI 10.1109/IMCEC.2018.8469292
[8]   Ensemble Deep Learning for Diabetic Retinopathy Detection Using Optical Coherence Tomography Angiography [J].
Heisler, Morgan ;
Karst, Sonja ;
Lo, Julian ;
Mammo, Zaid ;
Yu, Timothy ;
Warner, Simon ;
Maberley, David ;
Beg, Mirza Faisal ;
Navajas, Eduardo, V ;
Sarunic, Marinko, V .
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2020, 9 (02) :1-11
[9]   Densitometry of Choroidal Vessels in Eyes With and Without Central Serous Chorioretinopathy by Wide-Field Indocyanine Green Angiography [J].
Hirahara, Shuichiro ;
Yasukawa, Tsutomu ;
Kominami, Aoi ;
Nozaki, Miho ;
Ogura, Yuichiro .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2016, 166 :103-111
[10]   Current state and future prospects of artificial intelligence in ophthalmology: a review [J].
Hogarty, Daniel T. ;
Mackey, David A. ;
Hewitt, Alex W. .
CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2019, 47 (01) :128-139