Vertical marginal fit of zirconia copings fabricated with one direct and three indirect digital scanning techniques

被引:10
|
作者
Akhlaghian, Marzieh [1 ]
Khaledi, Amir-Alireza [1 ]
Farzin, Mitra [1 ]
Pardis, Soheil [2 ]
机构
[1] Shiraz Univ Med Sci, Sch Dent, Dept Prosthodont, Qomabad Ave,Qasrodasht St, Shiraz, Fars, Iran
[2] Shiraz Univ Med Sci, Sch Dent, Dept Oral & Maxillofacial Pathol, Shiraz, Fars, Iran
关键词
DENTAL IMPRESSIONS; DATA-ACQUISITION; ACCURACY; CROWNS; RESTORATIONS; ADAPTATION; STRENGTH; SYSTEM;
D O I
10.1016/j.prosdent.2020.03.028
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Direct digitization of the impression by using an intraoral scanner is a newly introduced technique, but studies comparing the method with other digitization techniques are lacking. Purpose. The purpose of this in vitro study was to compare the marginal accuracy of zirconia copings fabricated with 4 different scanning methods. Material and methods. Scans (n=10) of a brass master die were made with a direct method (ISD) in which the die was directly digitized by using an intraoral scanner (IOS) and 3 indirect scanning methods, a conventional impression with polyvinyl siloxane material digitized with either the same IOS (ISI) or with a laboratory extraoral scanner (ESI), or a cast from the impression was scanned by using a laboratory extraoral scanner (ESC). Forty zirconia copings were milled from presintered zirconia blanks and sintered. The vertical marginal gap was measured at 12 points on the master die by using a digital microscope. One-way ANOVA was used to compare the mean differences among the 4 groups, and post hoc analysis was used for pairwise comparison of the groups (a=.05). Results. The mean +/- standard deviation of the vertical marginal gap was 73 +/- 7 mm in the ISD group, 109 +/- 36 mm in the ISI group, 42 +/- 4 mm in the ESI group, and 97 +/- 5 mm in the ESC group. The lowest marginal gap was seen in the ESI group, which was significantly different from the 3 other groups (P<.001). The copings in the ISD group had a significantly lower marginal gap than those in the ISI (P=.04) and ESC (P<.001) groups. However, the ISI and ESC groups were not significantly different (P=.69). Conclusions. Marginal adaptation of all zirconia copings fabricated with these 4 scanning techniques was within a clinically acceptable range. However, ESI was the best method of digitization and yielded copings with minimum vertical marginal gap.
引用
收藏
页码:421 / 426
页数:6
相关论文
共 34 条
  • [31] Virtual Evaluation of the Accuracy of Fit and Trueness in Maxillary Poly(etheretherketone) Removable Partial Denture Frameworks Fabricated by Direct and Indirect CAD/CAM Techniques
    Negm, Enas Elhamy
    Aboutaleb, Faten Ahmed
    Alam-Eldein, Ahmed M.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (07): : 804 - 810
  • [32] Marginal and internal fit of posterior three-unit fixed zirconia dental prostheses fabricated with two different CAD/CAM systems and materials
    Schoenberger, Joana
    Erdelt, Kurt-Juergen
    Baeumer, Daniel
    Beuer, Florian
    CLINICAL ORAL INVESTIGATIONS, 2017, 21 (08) : 2629 - 2635
  • [33] The Influence of Three Different Digital Cement Spacers on the Marginal Gap Adaptation of Zirconia-Reinforced Lithium Silicate Crowns Fabricated by CAD-CAM System
    Ben-Izhack, Gil
    Shely, Asaf
    Naishlos, Sarit
    Glikman, Ari
    Frishman, Liad
    Meirowitz, Avi
    Dolev, Eran
    APPLIED SCIENCES-BASEL, 2021, 11 (22):
  • [34] Comparison of the accuracy of bracket positioning between direct and digital indirect bonding techniques in the maxillary arch: a three-dimensional study
    Aboujaoude, Rami
    Kmeid, Roland
    Gebrael, Carine
    Amm, Elie
    PROGRESS IN ORTHODONTICS, 2022, 23 (01)