Vertical marginal fit of zirconia copings fabricated with one direct and three indirect digital scanning techniques

被引:10
|
作者
Akhlaghian, Marzieh [1 ]
Khaledi, Amir-Alireza [1 ]
Farzin, Mitra [1 ]
Pardis, Soheil [2 ]
机构
[1] Shiraz Univ Med Sci, Sch Dent, Dept Prosthodont, Qomabad Ave,Qasrodasht St, Shiraz, Fars, Iran
[2] Shiraz Univ Med Sci, Sch Dent, Dept Oral & Maxillofacial Pathol, Shiraz, Fars, Iran
关键词
DENTAL IMPRESSIONS; DATA-ACQUISITION; ACCURACY; CROWNS; RESTORATIONS; ADAPTATION; STRENGTH; SYSTEM;
D O I
10.1016/j.prosdent.2020.03.028
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Direct digitization of the impression by using an intraoral scanner is a newly introduced technique, but studies comparing the method with other digitization techniques are lacking. Purpose. The purpose of this in vitro study was to compare the marginal accuracy of zirconia copings fabricated with 4 different scanning methods. Material and methods. Scans (n=10) of a brass master die were made with a direct method (ISD) in which the die was directly digitized by using an intraoral scanner (IOS) and 3 indirect scanning methods, a conventional impression with polyvinyl siloxane material digitized with either the same IOS (ISI) or with a laboratory extraoral scanner (ESI), or a cast from the impression was scanned by using a laboratory extraoral scanner (ESC). Forty zirconia copings were milled from presintered zirconia blanks and sintered. The vertical marginal gap was measured at 12 points on the master die by using a digital microscope. One-way ANOVA was used to compare the mean differences among the 4 groups, and post hoc analysis was used for pairwise comparison of the groups (a=.05). Results. The mean +/- standard deviation of the vertical marginal gap was 73 +/- 7 mm in the ISD group, 109 +/- 36 mm in the ISI group, 42 +/- 4 mm in the ESI group, and 97 +/- 5 mm in the ESC group. The lowest marginal gap was seen in the ESI group, which was significantly different from the 3 other groups (P<.001). The copings in the ISD group had a significantly lower marginal gap than those in the ISI (P=.04) and ESC (P<.001) groups. However, the ISI and ESC groups were not significantly different (P=.69). Conclusions. Marginal adaptation of all zirconia copings fabricated with these 4 scanning techniques was within a clinically acceptable range. However, ESI was the best method of digitization and yielded copings with minimum vertical marginal gap.
引用
收藏
页码:421 / 426
页数:6
相关论文
共 34 条
  • [21] Marginal Fit of Lithium Disilicate Crowns Fabricated Using Conventional and Digital Methodology: A Three-Dimensional Analysis
    Mostafa, Nezrine Z.
    Ruse, N. Dorin
    Ford, Nancy L.
    Carvalho, Ricardo M.
    Wyatt, Chris C. L.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2018, 27 (02): : 145 - 152
  • [22] Marginal and internal fit of lithium disilicate endocrowns fabricated using conventional, digital, and combination techniques
    Abduljawad, Danyh Emad
    Rayyan, Mohammad Ramadan
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2022, 34 (04) : 707 - 714
  • [23] Marginal and internal fit of five-unit zirconia-based fixed dental prostheses fabricated with digital scans and conventional impressions: A comparative in vitro study
    Bandiaky, Octave Nadile
    Clouet, Roselyne
    Le Bars, Pierre
    Soueidan, Assem
    Le Guehennec, Laurent
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (09): : 846 - 853
  • [24] Evaluation of the vertical Marginal Fit of CAD- CAM Zirconia, Pressable Lithium Disilicate, CAD-CAM Cobalt Chromium and Direct Metal Laser Sintered Cobalt Chromium Copings- An Invitro Comparative Analysis
    Kandi, Nikita
    Sabane, Ajay
    Patil, Abhijit
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2020, 14 (07) : ZC30 - ZC36
  • [25] Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques
    Almeida e Silva, Junio S.
    Erdelt, Kurt
    Edelhoff, Daniel
    Araujo, Elito
    Stimmelmayr, Michael
    Cardoso Vieira, Luiz Clovis
    Gueth, Jan-Frederik
    CLINICAL ORAL INVESTIGATIONS, 2014, 18 (02) : 515 - 523
  • [26] Marginal and Internal Fit of Ceramic Restorations Fabricated Using Digital Scanning and Conventional Impressions: A Clinical Study
    Lee, Jeong-Hyeon
    Son, Keunbada
    Lee, Kyu-Bok
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (12) : 1 - 11
  • [27] Influence of glazing and aging on the marginal, axial, axio-occlusal, and occlusal fit of 3-unit monolithic zirconia restorations fabricated using additive and subtractive techniques
    Toksoy, Dilem
    Onoral, Ozay
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (04) : 658.e1 - 658.e9
  • [28] An evaluation of marginal fit of three-unit fixed dental prostheses fabricated by direct metal laser sintering system
    Kim, Ki-Baek
    Kim, Woong-Chul
    Kim, Hae-Young
    Kim, Ji-Hwan
    DENTAL MATERIALS, 2013, 29 (07) : E91 - E96
  • [29] Clinical marginal fit of zirconia crowns and patients' preferences for impression techniques using intraoral digital scanner versus polyvinyl siloxane material
    Sakornwimon, Nawapat
    Leevailoj, Chalermpol
    JOURNAL OF PROSTHETIC DENTISTRY, 2017, 118 (03) : 386 - 391
  • [30] Accuracy of marginal fit and axial wall contour for lithium disilicate crowns fabricated using three digital workflows
    Sadid-Zadeh, Ramtin
    Katsavochristou, Anastasia
    Squires, Taylor
    Simon, Michael
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (01) : 121 - 127