Simple Low-Cost System for Thickness Measurement of Metallic Plates Using Laser Mouse Navigation Sensor

被引:5
作者
Charniya, Nadir Nizar Ali [1 ]
Dudul, Sanjay Vasant [2 ]
机构
[1] Babasaheb Naik Coll Engn, Dept Elect & Telecommun Engn, Pusad 445215, India
[2] St Gadge Baba Amravati Univ, PG Dept Appl Elect, Amravati 444602, India
关键词
Laser mouse; laser mouse navigation sensor; optical mouse; thickness measurement; SHEET-THICKNESS; OPTICAL MOUSE;
D O I
10.1109/TIM.2010.2045555
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A simple low-cost sensor system for thickness measurement of metallic plates by means of a high-resolution laser mouse navigation sensor and a lightweight displacement probe is presented in this paper. An experimental prototype was developed, which involves release of the probe freely on the plain surface of metallic plates under test. A signal is generated from the laser mouse during the release of the probe. The first minima of the signals are related to the thickness of the metallic plates.
引用
收藏
页码:2700 / 2705
页数:6
相关论文
共 23 条
[1]  
*AG TECHN INC, 2002, AG ADSN OPT MOUS SEN
[2]  
Akamatsu M., 1994, Proceedings. 3rd IEEE International Workshop on Robot and Human Communication. RO-MAN '94 Nagoya (Cat. No.94TH0679-1), P140, DOI 10.1109/ROMAN.1994.365941
[3]  
Bonarini A, 2005, IEEE INT CONF ROBOT, P1675
[4]   Neural Network based sensor for classification of material type and its surface properties [J].
Charniya, Nadir N. ;
Dudul, Sanjay V. .
2007 IEEE INTERNATIONAL JOINT CONFERENCE ON NEURAL NETWORKS, VOLS 1-6, 2007, :424-+
[5]   Sensor for Classification of Material Type and Its Surface Properties Using Radial Basis Networks [J].
Charniya, Nadir Nizar Ali ;
Dudul, Sanjay Vasant .
IEEE SENSORS JOURNAL, 2008, 8 (11-12) :1981-1991
[6]   Application of tilt sensors in human-computer mouse interface for people with disabilities [J].
Chen, YL .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2001, 9 (03) :289-294
[7]  
*CYPR SEM CORP, 2008, OVATIONONS CYONS1001
[8]   A simple device to monitor flexion and lateral bending of the lumbar spine [J].
Donatell, GJ ;
Meister, DW ;
O'Brien, JR ;
Thurlow, JS ;
Webster, JG ;
Salvi, FJ .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2005, 13 (01) :18-23
[9]  
DUNCAN R, 1986, ADV MS DOS PROGRAMMI
[10]   Narrow-band frequency analysis for laser-based glass thickness measurement [J].
He, B ;
Cabestaing, F ;
Postaire, JG ;
Zhang, RD .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2005, 54 (01) :222-227