Durability of prostheses for transcatheter aortic valve implantation

被引:130
作者
Arsalan, Mani [1 ]
Walther, Thomas [1 ]
机构
[1] Kerckhoff Heart Ctr, Dept Cardiac Surg, Benekestr 2-8, D-61231 Bad Nauheim, Germany
关键词
MITROFLOW PERICARDIAL BIOPROSTHESIS; LONG-TERM DURABILITY; INFECTIVE ENDOCARDITIS; STRUCTURAL INTEGRITY; RISK-FACTORS; FOLLOW-UP; REPLACEMENT; OUTCOMES; STENTLESS; EXPERIENCE;
D O I
10.1038/nrcardio.2016.43
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Transcatheter aortic valve implantation (TAVI) has become the standard of care for inoperable patients, and the preferred treatment option for high-risk patients with severe aortic stenosis. Given that this therapy was intended for elderly patients with limited life expectancy, long-term durability has not been in the focus. Now that TAVI is increasingly being used in patients with intermediate-risk and lower-risk profiles, device durability has gained importance. The available mid-term results for TAVI are promising; however, little is known about the fate of TAVI devices beyond 5 years. The experience with long-term durability of surgical valves shows that >= 10-year follow-up is required to ensure reliable durability data. In this Review, we discuss the existing studies of TAVI durability, highlight differences between surgical and transcatheter treatment of aortic stenosis that might influence durability, and present a clinical solution for failed prostheses. Furthermore, we suggest how device durability might influence the future selection of patients for TAVI.
引用
收藏
页码:360 / 367
页数:8
相关论文
共 61 条
[31]   Simulated Thin Pericardial Bioprosthetic Valve Leaflet Deformation Under Static Pressure-Only Loading Conditions: Implications for Percutaneous Valves [J].
Li, Kewei ;
Sun, Wei .
ANNALS OF BIOMEDICAL ENGINEERING, 2010, 38 (08) :2690-2701
[32]   5-year outcomes of transcatheter aortic valve replacement or surgical aortic valve replacement for high surgical risk patients with aortic stenosis (PARTNER 1): a randomised controlled trial [J].
Mack, Michael J. ;
Leon, Martin B. ;
Smith, Craig R. ;
Miller, D. Craig ;
Moses, Jeffrey W. ;
Tuzcu, E. Murat ;
Webb, John G. ;
Douglas, Pamela S. ;
Anderson, William N. ;
Blackstone, Eugene H. ;
Kodali, Susheel K. ;
Makkar, Raj R. ;
Fontana, Gregory P. ;
Kapadia, Samir ;
Bavaria, Joseph ;
Hahn, Rebecca T. ;
Thourani, Vinod H. ;
Babaliaros, Vasilis ;
Pichard, Augusto ;
Herrmann, Howard C. ;
Brown, David L. ;
Williams, Mathew ;
Akin, Jodi ;
Davidson, Michael J. ;
Svensson, Lars G. .
LANCET, 2015, 385 (9986) :2477-2484
[33]   Possible Subclinical Leaflet Thrombosis in Bioprosthetic Aortic Valves [J].
Makkar, R. R. ;
Fontana, G. ;
Jilaihawi, H. ;
Chakravarty, T. ;
Kofoed, K. F. ;
de Backer, O. ;
Asch, F. M. ;
Ruiz, C. E. ;
Olsen, N. T. ;
Trento, A. ;
Friedman, J. ;
Berman, D. ;
Cheng, W. ;
Kashif, M. ;
Jelnin, V. ;
Kliger, C. A. ;
Guo, H. ;
Pichard, A. D. ;
Weissman, N. J. ;
Kapadia, S. ;
Manasse, E. ;
Bhatt, D. L. ;
Leon, M. B. ;
Sondergaard, L. .
NEW ENGLAND JOURNAL OF MEDICINE, 2015, 373 (21) :2015-2024
[34]   Comparison of transcatheter aortic valve and surgical bioprosthetic valve durability: A fatigue simulation study [J].
Martin, Caitlin ;
Sun, Wei .
JOURNAL OF BIOMECHANICS, 2015, 48 (12) :3026-3034
[35]   LONG-TERM EXPERIENCE WITH THE IONESCU-SHILEY PERICARDIAL VALVE [J].
MASTERS, RG ;
WALLEY, VM ;
PIPE, AL ;
KEON, WJ .
ANNALS OF THORACIC SURGERY, 1995, 60 (02) :S288-S291
[36]   DURABILITY OF THE MITROFLOW PERICARDIAL VALVE AT 10 YEARS [J].
MAZZUCOTELLI, JP ;
BERTRAND, PC ;
LOISANCE, DY .
ANNALS OF THORACIC SURGERY, 1995, 60 (02) :S303-S304
[37]   Late Outcomes for Aortic Valve Replacement With the Carpentier-Edwards Pericardial Bioprosthesis: Up to 17-Year Follow-Up in 1,000 Patients [J].
McClure, R. Scott ;
Narayanasamy, Narendren ;
Wiegerinck, Esther ;
Lipsitz, Stuart ;
Maloney, Ann ;
Byrne, John G. ;
Aranki, Sary F. ;
Couper, Gregory S. ;
Cohn, Lawrence H. .
ANNALS OF THORACIC SURGERY, 2010, 89 (05) :1410-1416
[38]   Stent Fracture, Valve Dysfunction, and Right Ventricular Outflow Tract Reintervention After Transcatheter Pulmonary Valve Implantation Patient-Related and Procedural Risk Factors in the US Melody Valve Trial [J].
McElhinney, Doff B. ;
Cheatham, John P. ;
Jones, Thomas K. ;
Lock, James E. ;
Vincent, Julie A. ;
Zahn, Evan M. ;
Hellenbrand, William E. .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (06) :602-U130
[39]   Mitroflow synergy prostheses for aortic valve replacement:: 19 years experience with 1,516 patients [J].
Minami, K ;
Zittermann, A ;
Schulte-Eistrup, S ;
Koertke, H ;
Körfer, R .
ANNALS OF THORACIC SURGERY, 2005, 80 (05) :1699-1705
[40]   Long-Term Clinical and Echocardiographic Follow-Up of the Freestyle Stentless Aortic Bioprosthesis [J].
Mohammadi, Siamak ;
Tchana-Sato, Vincent ;
Kalavrouziotis, Dimitri ;
Voisine, Pierre ;
Doyle, Daniel ;
Baillot, Richard ;
Sponga, Sandro ;
Metras, Jacques ;
Perron, Jean ;
Dagenais, Francois .
CIRCULATION, 2012, 126 (11) :S198-S204