Durability of prostheses for transcatheter aortic valve implantation

被引:126
作者
Arsalan, Mani [1 ]
Walther, Thomas [1 ]
机构
[1] Kerckhoff Heart Ctr, Dept Cardiac Surg, Benekestr 2-8, D-61231 Bad Nauheim, Germany
关键词
MITROFLOW PERICARDIAL BIOPROSTHESIS; LONG-TERM DURABILITY; INFECTIVE ENDOCARDITIS; STRUCTURAL INTEGRITY; RISK-FACTORS; FOLLOW-UP; REPLACEMENT; OUTCOMES; STENTLESS; EXPERIENCE;
D O I
10.1038/nrcardio.2016.43
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Transcatheter aortic valve implantation (TAVI) has become the standard of care for inoperable patients, and the preferred treatment option for high-risk patients with severe aortic stenosis. Given that this therapy was intended for elderly patients with limited life expectancy, long-term durability has not been in the focus. Now that TAVI is increasingly being used in patients with intermediate-risk and lower-risk profiles, device durability has gained importance. The available mid-term results for TAVI are promising; however, little is known about the fate of TAVI devices beyond 5 years. The experience with long-term durability of surgical valves shows that >= 10-year follow-up is required to ensure reliable durability data. In this Review, we discuss the existing studies of TAVI durability, highlight differences between surgical and transcatheter treatment of aortic stenosis that might influence durability, and present a clinical solution for failed prostheses. Furthermore, we suggest how device durability might influence the future selection of patients for TAVI.
引用
收藏
页码:360 / 367
页数:8
相关论文
共 61 条
  • [1] Aortic regurgitation after transcatheter aortic valve implantation: incidence and early outcome. Results from the German transcatheter aortic valve interventions registry
    Abdel-Wahab, Mohamed
    Zahn, Ralf
    Horack, Martin
    Gerckens, Ulrich
    Schuler, Gerhard
    Sievert, Horst
    Eggebrecht, Holger
    Senges, Jochen
    Richardt, Gert
    [J]. HEART, 2011, 97 (11) : 899 - 906
  • [2] Infective Endocarditis After Transcatheter Aortic Valve Implantation Results From a Large Multicenter Registry
    Amat-Santos, Ignacio J.
    Messika-Zeitoun, David
    Eltchanino, Helene
    Kapadia, Samir
    Lerakis, Stamatios
    Cheema, Asim N.
    Gutierrez-Ibanes, Enrique
    Munoz-Garcia, Antonio J.
    Pan, Manuel
    Webb, John G.
    Herrmann, Howard C.
    Kodali, Susheel
    Notnbela-Franco, Luis
    Tamburino, Corrado
    Jilaihawi, Hasan
    Masson, Jean-Bernard
    de Brito, Fabio Sandoli, Jr.
    Ferreira, Maria Cristina
    Lima, Valter Correa
    Mangione, Jose Armando
    Iung, Bernard
    Vahanian, Alec
    Durand, Eric
    Tuzcu, E. Murat
    Hayek, Salim S.
    Angulo-Llanos, Rocio
    Gomez-Doblas, Juan J.
    Castillo, Juan Carlos
    Dvir, Danny
    Leon, Martin B.
    Garcia, Eulogio
    Cobiella, Javier
    Vilacosta, Isidre
    Barbanti, Marco
    Makkar, Raj R.
    Ribeiro, Henrique Barbosa
    Urena, Marina
    Dumont, Eric
    Pibarot, Philippe
    Lopez, Javier
    San Roman, Alberto
    Rodes-Cabau, Josep
    [J]. CIRCULATION, 2015, 131 (18) : 1566 - 1574
  • [3] Age and valve size effect on the long-term durability of the Carpentier-Edwards aortic pericardial bioprosthesis
    Banbury, MK
    Cosgrove, DM
    White, JA
    Blackstone, EH
    Frater, RWM
    Okies, JE
    [J]. ANNALS OF THORACIC SURGERY, 2001, 72 (03) : 753 - 757
  • [4] 5-Year Outcomes After Transcatheter Aortic Valve Implantation With CoreValve Prosthesis
    Barbanti, Marco
    Petronio, Anna Sonia
    Ettori, Federica
    Latib, Azeem
    Bedogni, Francesco
    De Marco, Federico
    Poli, Arnaldo
    Boschetti, Carla
    De Carlo, Marco
    Fiorina, Claudia
    Colombo, Antonio
    Brambilla, Nedy
    Bruschi, Giuseppe
    Martina, Paola
    Pandolfi, Claudia
    Giannini, Cristina
    Curello, Salvatore
    Sgroi, Carmelo
    Gulino, Simona
    Patane, Martina
    Ohno, Yohei
    Tamburino, Claudia
    Attizzani, Guilherme F.
    Imme, Sebastiano
    Gentili, Alessandra
    Tamburino, Corrado
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (08) : 1084 - 1091
  • [5] Beckmann A, 2015, THORAC CARDIOV SURG, V63, P258, DOI 10.1055/s-0035-1551676
  • [6] Biglioli P, 2004, J HEART VALVE DIS, V13, pS49
  • [7] Very Long-Term Outcomes of the Carpentier-Edwards Perimount Valve in Aortic Position
    Bourguignon, Thierry
    Bouquiaux-Stablo, Anne-Lorraine
    Candolfi, Pascal
    Mirza, Alain
    Loardi, Claudia
    May, Marc-Antoine
    El-Khoury, Rym
    Marchand, Michel
    Aupart, Michel
    [J]. ANNALS OF THORACIC SURGERY, 2015, 99 (03) : 831 - 837
  • [8] Butany J, 2001, J Long Term Eff Med Implants, V11, P115
  • [9] Modes of Failure in Explanted Mitroflow Pericardial Valves
    Butany, Jagdish
    Feng, Tianshu
    Luk, Adriana
    Law, Kelsey
    Suri, Rahul
    Nair, Vidhya
    [J]. ANNALS OF THORACIC SURGERY, 2011, 92 (05) : 1621 - +
  • [10] Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis - First human case description
    Cribier, A
    Eltchaninoff, H
    Bash, A
    Borenstein, N
    Tron, C
    Bauer, F
    Derumeaux, G
    Anselme, F
    Laborde, F
    Leon, MB
    [J]. CIRCULATION, 2002, 106 (24) : 3006 - 3008