Direct measurement of power during one single sprint on treadmill

被引:71
作者
Morin, J. B. [1 ,2 ]
Samozino, P. [1 ,2 ]
Bonnefoy, R. [1 ,2 ]
Edouard, P. [1 ,2 ]
Belli, A. [1 ,2 ]
机构
[1] Univ Lyon, F-42023 St Etienne, France
[2] Lab Exercise Physiol EA4338, F-42000 St Etienne, France
关键词
Maximal intensity; Running; Ergometer; Dynamometer; NON-MOTORIZED TREADMILL; GROUND REACTION FORCES; CYCLE ERGOMETER; VELOCITY RELATIONSHIP; MAXIMAL POWER; OUTPUT; PERFORMANCE; EXERCISE; STIFFNESS; MECHANICS;
D O I
10.1016/j.jbiomech.2010.03.012
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We tested the validity of an instrumented treadmill dynamometer for measuring maximal propulsive power during sprint running, and sought to verify whether this could be done over one single sprint, as shown during sprint cycling. The treadmill dynamometer modified towards sprint use (constant motor torque) allows vertical and horizontal forces to be measured at the same location as velocity, i.e. at the foot, which is novel compared to existing methods in which power is computed as the product of belt velocity and horizontal force measured by transducers placed in the tethering system. Twelve males performed 6 s sprints against default, high and low loads set from the motor torque necessary to overcome the friction due to subjects' weight on the belt (default load), and 20% higher and lower motor torque values. Horizontal ground reaction force, belt velocity, propulsive power and linear force-velocity relationships were compared between the default load condition and when taking all conditions together. Force and velocity traces and values were reproducible and consistent with the literature, and no significant difference was found between maximal power and force-velocity relationships obtained in the default load condition only vs. adding data from all conditions. The presented method allows one to measure maximal propulsive power and calculate linear force-velocity relationships from one single sprint data. The main novelties are that both force and velocity are measured at the same location, and that instantaneous values are averaged over one contact period, and not over a constant arbitrary time-window. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1970 / 1975
页数:6
相关论文
共 27 条
  • [1] A treadmill ergometer for three-dimensional ground reaction forces measurement during walking
    Belli, A
    Bui, P
    Berger, A
    Geyssant, A
    Lacour, JR
    [J]. JOURNAL OF BIOMECHANICS, 2001, 34 (01) : 105 - 112
  • [2] BELLI A, 1989, P 12 INT C BIOM
  • [3] FORCE PLATFORMS AS ERGOMETERS
    CAVAGNA, GA
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1975, 39 (01) : 174 - 179
  • [4] MECHANICS OF SPRINT RUNNING
    CAVAGNA, GA
    KOMAREK, L
    MAZZOLENI, S
    [J]. JOURNAL OF PHYSIOLOGY-LONDON, 1971, 217 (03): : 709 - +
  • [5] Cheetham M E, 1985, Br J Sports Med, V19, P81
  • [6] Chelly SM, 2001, MED SCI SPORT EXER, V33, P326
  • [7] Mechanical comparison of barefoot and shod running
    Divert, C
    Mornieux, G
    Baur, H
    Mayer, F
    Belli, A
    [J]. INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2005, 26 (07) : 593 - 598
  • [8] Falk B, 1996, SCAND J MED SCI SPOR, V6, P259
  • [9] Ergometry for estimation of mechanical power output in sprinting in humans using a newly developed self-driven treadmill
    Funato, K
    Yanagiya, T
    Fukunaga, T
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2001, 84 (03) : 169 - 173
  • [10] Comparison of treadmill and cycle ergometer measurements of force-velocity relationships and power output
    Jaskólska, A
    Goossens, P
    Veenstra, B
    Jaskólski, A
    Skinner, JS
    [J]. INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1999, 20 (03) : 192 - 197