Thermal Modelling of a Control Center for Flexibility Analysis in nZEB Nanogrids

被引:2
作者
Haring, Tobias [1 ,2 ]
Rosin, Argo [1 ,2 ]
Kull, Tuule Mall [3 ]
Helguero, Jorge [4 ]
Biechl, Helmuth [4 ]
机构
[1] Tallinn Univ Technol, Smart City Ctr Excellence Finest Twins, Tallinn, Estonia
[2] Tallinn Univ Technol, Dept Elect Power Engn & Mechatron, Tallinn, Estonia
[3] Tallinn Univ Technol, Dept Civil Engn & Architecture, Tallinn, Estonia
[4] Univ Appl Sci Kempten, Inst Elect Power Syst IEES, Kempten, Germany
来源
2020 IEEE 61ST ANNUAL INTERNATIONAL SCIENTIFIC CONFERENCE ON POWER AND ELECTRICAL ENGINEERING OF RIGA TECHNICAL UNIVERSITY (RTUCON) | 2020年
基金
欧盟地平线“2020”;
关键词
Flexibility; Smart City; nZEB; Thermal Storage; Space Heating; Demand Response; Nanogrid; STORAGES;
D O I
10.1109/RTUCON51174.2020.9316568
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Due to the increasing share of volatile renewable energy sources, like photovoltaics (PV) and wind energy in nearly Zero Energy Buildings (nZEB), there is an increasing need for demand-side management (DSM) or demand response (DR) programs to balance the production and consumption in the grid. The flexibility that can be obtained for smart grids from such DR methods is not limited to appliances like water heaters or dishwashers but can also be achieved with space heating and air-conditioning. In such an interdisciplinary investigation, often one part is simplified, in this case, typically either the thermal models or the implemented DR strategy are very detailed. In this work, a detailed thermal model of a control center is obtained and calibrated in IDA ICE building-modelling software with measurements from a test site in Germany. Afterward, several price-based load matching algorithms are applied to the model to see the possible flexibility exploitation with the thermal capacity of this small building. Not all investigated algorithms show good performance but some of them show promising results. Thus, this model can be used for DR methods and should be extended to work with more DSM strategies and provide ancillary services.
引用
收藏
页数:6
相关论文
共 19 条
[1]  
Aleixo Luis, 2013, 22nd International Conference and Exhibition on Electricity Distribution (CIRED 2013)
[2]  
[Anonymous], 2019, 2019 13 INT C MATH, DOI DOI 10.1109/macs48846.2019.9024788
[3]  
[Anonymous], 0402 CEIC
[4]  
[Anonymous], 2007, PACIFIC NW GRIDWISET
[5]   Model complexity of heat pump systems to investigate the building energy flexibility and guidelines for model implementation [J].
Clauss, John ;
Georges, Laurent .
APPLIED ENERGY, 2019, 255
[6]  
Feron B., 2017, Proceedings of 2017 IEEE Power Energy Society General Meeting, P1, DOI [DOI 10.1109/PESGM.2017.8273810, 10.1109/ PESGM.2017.8273810]
[7]   Validation of a transient zonal model to predict the detailed indoor thermal environment: Case of electric radiators and wood stoves [J].
Georges, L. ;
Thalfeldt, M. ;
Skreiberg, O. ;
Fornari, W. .
BUILDING AND ENVIRONMENT, 2019, 149 :169-181
[8]  
Haring T., 2018, RES DEV THERMAL STOR
[9]  
Haring T., 2019, 2019 ELECT POWER QUA, P1
[10]  
Häring T, 2019, IEEE IND ELEC, P2541, DOI 10.1109/IECON.2019.8927495