Application of the AhR reporter gene assay for the determination of PCDD/Fs and DL-PCBs in feed samples

被引:3
作者
Piskorska-Pliszczynska, Jadwiga [1 ]
Malagocki, Pawel [1 ]
Furga, Beata [1 ]
Gembal, Magdalena [1 ]
Cebulska, Joanna [1 ]
机构
[1] Natl Vet Res Inst, Radiobiol Dept, PL-24100 Pulawy, Poland
关键词
feedstuffs; dioxins; dioxin-like polychlorinated biphenyls; bioassay; TOXIC EQUIVALENCY FACTORS; CALUX BIOASSAY; DIOXINS; FOOD; VALIDATION; CHEMICALS; SYSTEMS;
D O I
10.1515/jvetres-2017-0066
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Introduction: Polychlorinated dibenzo-p-dioxins, polychlorinated dibenzofurans (PCDD/Fs) and dioxin-like polychlorinated biphenyls (DL-PCBs) belong to a well-known group of pollutants. Present in feedstuffs, they bioaccumulate in tissues of food-producing animals. Food is the source of over 90% of human PCDD/Fs and DL-PCBs intake. Thus, feed control is one of the pillars of the EU strategy and a mean of reducing human exposure. The article presents AhR based reporter gene bioassay method for PCDD/Fs and DL-PCBs analysis in feed and its validation results. Material and Methods: Analytes were extracted from samples with fat. Subsequently, fat and other interferences were removed from extract using sulphuric acid modified silica. Extract was further cleaned and PCDD/Fs separated from DL-PCBs using carbon column. Contaminants detection was performed using H1L6.1c3 cell line, which produces luciferase in response to AhR ligands present in extract. Results: Performance characteristics (repeatability, reproducibility, and apparent recovery) fulfil the requirements of Regulation 2017/771/EU. The positive correlation between bioassay and reference HRGC-HRMS method was confirmed. Moreover, the role of screening method used in connection with the confirmatory HRGC-HRMS method in providing feed and food safety has been discussed. Conclusion: Bioassay is a useful method for dioxin and DL-PCBs analysis, allowing cost reduction of monitoring programmes with minimal risk of false negative results.
引用
收藏
页码:473 / 481
页数:9
相关论文
共 29 条
[1]  
Behnisch P.A., 2001, ORGANOHALOGEN COMPD, V50, P59
[2]   The Belgian PCB/dioxin incident: Analysis of the food chain contamination and health risk evaluation [J].
Bernard, A ;
Broeckaert, F ;
De Poorter, G ;
De Cock, A ;
Hermans, C ;
Saegerman, C ;
Houins, G .
ENVIRONMENTAL RESEARCH, 2002, 88 (01) :1-18
[3]   Validation and regulatory acceptance of bio-based approaches to assure feedstock, water & product quality in a bio-based economy [J].
Besselink, Harrie ;
Brouwer, Bram ;
van der Burg, Bart .
INDUSTRIAL CROPS AND PRODUCTS, 2017, 106 :138-145
[4]   THE MECHANISM OF DIOXIN TOXICITY - RELATIONSHIP TO RISK ASSESSMENT [J].
BIRNBAUM, LS .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1994, 102 :157-167
[5]   Recombinant cell bioassay systems for the detection and relative quantitation of halogenated dioxins and related chemicals [J].
Denison, MS ;
Zhao, B ;
Baston, DS ;
Clark, GC ;
Murata, H ;
Han, D .
TALANTA, 2004, 63 (05) :1123-1133
[6]  
EC (European Commission), 2001, OFFICIAL J EUROPEA C, V322, P2
[7]   In vitro bioassays for detecting dioxin-like activity - Application potentials and limits of detection, a review [J].
Eichbaum, Kathrin ;
Brinkmann, Markus ;
Buchinger, Sebastian ;
Reifferscheid, Georg ;
Hecker, Markus ;
Giesy, John P. ;
Engwall, Magnus ;
van Bavel, Bert ;
Hollert, Henner .
SCIENCE OF THE TOTAL ENVIRONMENT, 2014, 487 :37-48
[8]  
Focant JF, 2013, WOODHEAD PUBL FOOD S, V247, P47, DOI 10.1533/9780857098917.1.47
[9]  
Furga B., 2013, P ECOPOLE, V7, P325
[10]   Species-specific recombinant cell lines as bioassay systems for the detection of 2,3,7,8-tetrachlorodibenzo-p-dioxin-like chemicals [J].
Garrison, PM ;
Tullis, K ;
Aarts, JMMJG ;
Brouwer, A ;
Giesy, JP ;
Denison, MS .
FUNDAMENTAL AND APPLIED TOXICOLOGY, 1996, 30 (02) :194-203