Biomechanical Properties of Volar Hybrid and Locked Plate Fixation in Distal Radius Fractures

被引:20
作者
Sokol, Shima C. [1 ]
Amanatullah, Derek F. [1 ]
Curtiss, Shane [1 ]
Szabo, Robert M. [1 ]
机构
[1] Univ Calif Davis, Sch Med, Dept Orthopaed Surg, Sacramento, CA 95817 USA
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 2011年 / 36A卷 / 04期
关键词
Biomechanical; distal radius fracture; hybrid fixation; internal fixation; locking; volar plate; DORSALLY DISPLACED FRACTURES; INTERNAL-FIXATION; COMPRESSION PLATE; LOCKING SCREW; MODEL; COMPLICATIONS; STABILITY; STRENGTH;
D O I
10.1016/j.jhsa.2010.12.032
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose We compare the biomechanical properties of a volar hybrid construct to an all-locking construct in an osteoporotic and normal comminuted distal radius fracture model. Methods Groups of 28 normal, 28 osteoporotic, and 28 over-drilled osteoporotic left distal radius synthetic bones were used. The normal group consisted of synthetic bone with a standard foam core. The osteoporotic group consisted of synthetic bone with decreased foam core density. The over-drilled osteoporotic group consisted of synthetic bone with decreased foam core density and holes drilled with a 2.3 mm drill, instead of the standard 2.0 mm drill, to simulate the lack of purchase in osteoporotic bone. Within each group, 14 synthetic bones were plated with a volar locking plate using an all-locking screw construct, and 14 synthetic bones were plated with a volar locking plate using a hybrid screw construct (ie, both locking and nonlocking screws). A 1-cm dorsal wedge osteotomy was created with the apex 2 cm from the volar surface of the lunate facet. Each specimen was mounted to a materials testing machine, using a custom-built, standardized axial compression jig. Axial compression was delivered at 1 N/s over 3 cycles from 20 N to 100 N to establish stiffness. Each sample was stressed to failure at 1 minis until 5 mm of permanent deformation occurred. Results Our results show no difference in construct stiffness and load at failure between the all-locking and hybrid constructs in the normal, osteoporotic, or over-drilled osteoporotic synthetic bone models. All specimens failed by plate bending at the osteotomy site with loss of height. Clinical Relevance Although volar locking plates are commonly used for the treatment of distal radius fractures, the ideal screw configuration has not been determined. Hybrid fixation has comparable biomechanical properties to all locking constructs in the fixation of metaphyseal fractures about the knee and shoulder and might also have a role in the fixation of distal radius fractures. (J Hand Surg 2011;36A:591-597. Copyright (c) 2011 by the American Society for Surgery of the Hand. All rights reserved.)
引用
收藏
页码:591 / 597
页数:7
相关论文
共 31 条
  • [1] Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate
    Arora, Rohit
    Lutz, Martin
    Hennerbichler, Alfred
    Krappinger, Dietinar
    Espen, David
    Gabl, Markus
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (05) : 316 - 322
  • [2] Two potential causes of EPL rupture after distal radius volar plate fixation
    Benson, Eric C.
    DeCarvalho, Alex
    Mikola, Elizabeth A.
    Veitch, John M.
    Moneim, Moheb S.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (451) : 218 - 222
  • [3] Mechanical characteristics of locking and compression plate constructs applied dorsally to distal radius fractures
    Boswell, Scott
    McIff, Terence E.
    Trease, Cory A.
    Toby, E. Bruce
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2007, 32A (05): : 623 - 629
  • [4] Mechanical validation of whole bone composite femur models
    Cristofolini, L
    Viceconti, M
    Cappello, A
    Toni, A
    [J]. JOURNAL OF BIOMECHANICS, 1996, 29 (04) : 525 - 535
  • [5] Osteosynthesis of distal radial fractures with a volar locking screw plate system
    Drobetz, H
    Kutscha-Lissberg, E
    [J]. INTERNATIONAL ORTHOPAEDICS, 2003, 27 (01) : 1 - 6
  • [6] Biomechanical strength of the Peri-Loc® proximal tibial plate:: A comparison of all-locked versus hybrid locked/nonlocked screw configurations
    Estes, Chris
    Rhee, Peter
    Shrader, M. Wade
    Csavina, Kristine
    Jacofsky, Marc C.
    Jacofsky, David J.
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2008, 22 (05) : 312 - 316
  • [7] Unstable Distal Radius Fractures in the Elderly Patient-Volar Fixed-Angle Plate Osteosynthesis Prevents Secondary Loss of Reduction
    Figl, Markus
    Weninger, Patrick
    Jurkowitsch, Josef
    Hofbauer, Marcus
    Schauer, Josef
    Leixnering, Martin
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2010, 68 (04): : 992 - 998
  • [8] Relative stability of conventional and locked plating fixation in a model of the osteoporotic femoral diaphysis
    Fitzpatrick, Daniel C.
    Doornink, Josef
    Madey, Steven M.
    Bottlang, Michael
    [J]. CLINICAL BIOMECHANICS, 2009, 24 (02) : 203 - 209
  • [9] Hybrid locked plating of osteoporotic fractures of the humerus
    Gardner, Michael J.
    Griffith, Matthew H.
    Demetrakopoulos, Demetris
    Brophy, Robert H.
    Grose, Andrew
    Helfet, David L.
    Lorich, Dean G.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (09) : 1962 - 1967
  • [10] DELAYED RUPTURE OF EXTENSOR DIGITORUM COMMUNIS TENDON FOLLOWING VOLAR PLATING OF DISTAL RADIUS FRACTURE
    Hattori, Yasunori
    Doi, Kazuteru
    Sakamoto, Soutetsu
    Yukata, Kiminori
    [J]. JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2008, 13 (03) : 183 - 185