Pulmonary artery pressure variation in patients with connective tissue disease: 24 hour ambulatory pulmonary artery pressure monitoring

被引:46
作者
Raeside, DA
Chalmers, G
Clelland, J
Madhok, R
Peacock, AJ [1 ]
机构
[1] Univ Glasgow, Dept Resp Med, Pulm Vascular Unit, Glasgow, Lanark, Scotland
[2] Univ Glasgow, Dept Cardiol, Glasgow, Lanark, Scotland
[3] W Glasgow Hosp Univ NHS Trust, Western Infirm, Glasgow, Lanark, Scotland
[4] Glasgow Royal Infirm, Univ NHS Trust, Ctr Rheumat Dis, Glasgow G4 0SF, Lanark, Scotland
关键词
secondary pulmonary hypertension; connective tissue disease; Doppler echocardiography; cardiac catheterisation; micromanometer tipped pulmonary artery catheter; ambulatory pulmonary pressure monitoring; ambulatory pressure variations; pulse pressure;
D O I
10.1136/thx.53.10.857
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background-The specific contribution of secondary pulmonary hypertension to the morbidity and mortality of patients with underlying lung disease can be difficult to assess from single measurements of pulmonary artery pressure. We have studied patients with secondary pulmonary hypertension using an ambulatory system for measuring continuous pulmonary artery pressure (PAP). We chose to study patients with connective tissue disease because they represent a group at high risk of pulmonary vascular disease, but with Little disturbance of lung function. Methods-Six patients (five with progressive systemic sclerosis and one with systemic lupus erythematosis) were studied. They underwent preliminary cardiopulmonary investigations followed by Doppler echocardiography, right heart catheterisation, and ambulatory pulmonary artery pressure monitoring to measure changes in pressure over a 24 hour period including during a formal exercise test. Results-All patients had pulmonary hypertension as measured by Doppler echocardiography with estimated pulmonary artery systolic pressures of 40-100 mm Hg. Pulmonary function testing revealed virtually normal spirometric values (mean FEV1 86.9% predicted) but marked reduction in CO gas transfer factor (Kco 57.8% predicted). Exercise responses were impaired with mean Vo(2)max 50.6% predicted. Ambulatory PAP monitoring indicated significant changes in pressures with variation in posture and activity throughout 24 hours. Resting PAP did not predict the change in PAP seen on exercise. Conclusion-Conventional methods of assessment of the pulmonary circulation based on single measurements in the supine position may underestimate the stresses faced by the right side of the circulation. This ambulatory system allows monitoring of pulmonary haemodynamics continuously over 24 hours during normal activities of daily living. These measurements may increase our understanding of the contribution made by secondary pulmonary hypertension to the morbidity and mortality of the underlying lung disease.
引用
收藏
页码:857 / 862
页数:6
相关论文
共 13 条
  • [1] BRECKER SJD, 1994, BRIT HEART J, V72, P384
  • [2] BRUNNER HR, 1985, J HYPERTENS, V3, pS13
  • [3] UNPREDICTABLE ZERO DRIFT IN INTRAVASCULAR MICROMANOMETER TIPPED CATHETERS DURING LONG-TERM PULMONARY-ARTERY PRESSURE RECORDING - IMPLICATIONS FOR CATHETER DESIGN
    GIBBS, JSR
    CUNNINGHAM, D
    SPARROW, J
    POOLEWILSON, PA
    FOX, KM
    [J]. CARDIOVASCULAR RESEARCH, 1989, 23 (02) : 152 - 158
  • [4] GIBBS JSR, 1989, BRIT HEART J, V62, P30
  • [5] GIBBS JSR, 1992, BRIT HEART J, V68, P230
  • [6] PULMONARY-ARTERY HEMODYNAMICS IN PRIMARY PULMONARY-HYPERTENSION
    LASKEY, WK
    FERRARI, VA
    PALEVSKY, HI
    KUSSMAUL, WG
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (02) : 406 - 412
  • [7] LEVY RD, 1986, BRIT HEART J, V56, P12
  • [8] Naeije R, 1996, PULMONARY CIRCULATIO, P13
  • [9] REEVES J, 1984, PULMONARY HYPERTENSI, P34
  • [10] PRIMARY PULMONARY-HYPERTENSION
    RUBIN, LJ
    [J]. CHEST, 1993, 104 (01) : 236 - 250