Electron spin resonance identification of irradiated ascorbic acid: Dosimetry and influence of powder fineness

被引:29
作者
Basly, JP
Basly, I
Bernard, M
机构
[1] UFR Pharm, F-87025 Limoges, France
[2] UFR Pharm, Lab Chim Analyt & Bromatol, F-87025 Limoges, France
关键词
ESR; dosimetry; ascorbic acid; radiosterilization;
D O I
10.1016/S0003-2670(98)00319-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
As an alternative to heat and gas exposure sterilization, ionizing radiation is gaining interest for sterilization of medicinal products. Detection and dosimetry of pharmaceuticals radiosterilization is a growing concern to numerous regulatory agencies worldwide; in this context, in the absence of suitable analytical methods, our attention was focused on electron spin resonance (ESR) spectrometry, This paper reports experimental data on the ESR identification of irradiated ascorbic acid and sodium ascorbate; also described are some data on powder fineness dependence in ESR dosimetry. While the ESR spectra of nonirradiated samples present no intensity, a signal, dependent on the irradiation dose, is found in irradiated samples. However, preliminary to the study, care was taken with the use of microwave power to avoid power saturation. The number of free radicals was estimated by comparison of the second integral from radiosterilized samples and diphenylpicrylhydrazyl standard; the values were in the range 1.5 x 10(19)-3.4 x 10(19) radicals mol(-1) (G from 0.05 to 0.12). Aside from qualitative detection, ESR spectrometry can be used for dose estimation. When an exponential function is applied to the variation of peak to peak amplitude vs, dose the function correlates well with the data. Free radical evolution vs. storage time was modelled using bi-exponential function. From this, the time limit from the irradiation (25 kGy) for identification of irradiated vitamins by ESR were evaluated. In commercially marketed drugs, radicals should be detectable up to two years after irradiation; this will probably be the case for the four samples (three samples of ascorbic acid of different powder fineness and one sample of sodium ascorbate) studied. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:373 / 378
页数:6
相关论文
共 12 条
[1]   ESR dosimetry of irradiated ascorbic acid [J].
Basly, JP ;
Longy, I ;
Bernard, M .
PHARMACEUTICAL RESEARCH, 1997, 14 (09) :1186-1191
[2]  
CIRANNISIGNORET.E, 1993, DRUG DEV IND PHARM, V19, P1693
[3]  
CIRANNISIGNORET.E, 1994, DRUG DEV IND PHARM, V20, P2493
[4]   ESTIMATION OF THE ABSORBED DOSE IN RADIATION-PROCESSED FOOD .2. TEST OF THE EPR RESPONSE FUNCTION BY AN EXPONENTIAL FITTING ANALYSIS [J].
DESROSIERS, MF .
APPLIED RADIATION AND ISOTOPES, 1991, 42 (07) :617-619
[5]   ELECTRON-SPIN-RESONANCE DETECTION OF IRRADIATED FOOD [J].
DODD, NJF ;
LEA, JS ;
SWALLOW, AJ .
NATURE, 1988, 334 (6181) :387-387
[6]  
*EN, 1994, 552 EN CEN EUR COM S
[7]  
*ISO, 1995, 11137 ISO INT ORG ST
[8]   ELECTRON-SPIN-RESONANCE STUDY OF RADIOSTERILIZATION OF ANTIBIOTICS - CEFTAZIDIME [J].
MIYAZAKI, T ;
KANEKO, T ;
YOSHIMURA, T ;
CRUCQ, AS ;
TILQUIN, B .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1994, 83 (01) :68-71
[9]   ESR identification of irradiated antibiotics: Cephalosporins [J].
Onori, S ;
Pantaloni, M ;
Fattibene, P ;
Signoretti, EC ;
Valvo, L ;
Santucci, M .
APPLIED RADIATION AND ISOTOPES, 1996, 47 (11-12) :1569-1572
[10]  
PLONKA A, 1991, Progress in Reaction Kinetics, V16, P157