Development and Evaluation of Deep Learning-Accelerated Single-Breath-Hold Abdominal HASTE at 3 T Using Variable Refocusing Flip Angles

被引:34
作者
Herrmann, Judith [1 ]
Nickel, Dominik [2 ]
Mugler, John P. [3 ]
Arberet, Simon [4 ]
Gassenmaier, Sebastian [1 ]
Afat, Saif [1 ]
Nikolaou, Konstantin [1 ]
Othman, Ahmed E. [1 ,5 ]
机构
[1] Eberhard Karls Univ Tuebingen, Dept Diagnost & Intervent Radiol, Hoppe Seyler Str 3, D-72076 Tubingen, Germany
[2] Siemens Healthcare GmbH, MR Applicat Predev, Erlangen, Germany
[3] Univ Virginia, Sch Med, Dept Radiol & Med Imaging, Charlottesville, VA 22908 USA
[4] Siemens Healthineers, Digital Technol & Innovat, Princeton, NJ USA
[5] Univ Med Ctr, Dept Neuroradiol, Mainz, Germany
关键词
acceleration; magnetic resonance imaging; deep learning reconstruction; image processing; diagnostic imaging; FAST SPIN-ECHO; OVERLAPPING PARALLEL LINES; IMAGE QUALITY; INCREASED SPEED; HEPATIC METASTASES; LIVER; RECONSTRUCTION; MRI;
D O I
10.1097/RLI.0000000000000785
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective Deep learning (DL) reconstruction enables substantial acceleration of image acquisition while maintaining diagnostic image quality. The aims of this study were to overcome the drawback of specific absorption rate (SAR)-related limitations at 3 T and to develop a DL-accelerated single-breath-hold half-Fourier acquisition single-shot turbo spin echo (HASTE) sequence for 2-dimesional T2-weighted fat-suppressed magnetic resonance imaging of the abdomen at 3 T using a variable flip angle (FA) evolution for the refocusing radiofrequency pulses, as well as to evaluate its feasibility and image quality in comparison to state-of-the-art T2-weighted fat-suppressed imaging technique (BLADE). Materials and Methods First, a suitable FA evolution with low cardiac motion-related signal loss (CRSL) and low SAR was determined through a prospective volunteer study with 11 participants. Image quality and diagnostic confidence with 5 different FA evolutions of a HASTE(DL) were assessed to identify the most suitable FA evolution. Second, the identified FA evolution was implemented clinically and evaluated in 51 patients undergoing a clinically indicated liver magnetic resonance imaging at 3 T. Two radiologists assessed the HASTE(DL) and standard sequences regarding overall image quality, noise, contrast, sharpness, artifacts, CRSL, and diagnostic confidence using a Likert scale ranging from 1 to 4, with 4 being the best. Comparative analyses were conducted to assess the differences between HASTE(DL) (acquisition time, 21 seconds; single breath-hold) and the routinely used T2-weighted BLADE sequence (acquisition time, 4 minutes; respiratory triggering). Results From the volunteer study, the FA evolution characterized by the control points 130-90-110-130 degrees (HASTE(DL)) was identified as optimal among the 5 evolutions evaluated and was implemented in our clinical protocol. In all 51 patients, HASTE(DL) was successfully acquired at 3 T and showed excellent image quality (median, 4; interquartile range, 3-4). Although BLADE was rated significantly higher for overall image quality, noise, contrast, sharpness, artifacts, CRSL, and diagnostic confidence than HASTE(DL), no differences were found concerning the number (n = 102) and measured diameter of the detected hepatic lesions between the 2 sequences BLADE and HASTE(DL). Conclusions The proposed single-breath-hold abdominal HASTE(DL) with variable refocusing FAs is feasible at 3 T within SAR limits and yields high image quality and diagnostic confidence as compared with a standard T2-weighted acquisition technique, at a 10th of the acquisition time.
引用
收藏
页码:645 / 652
页数:8
相关论文
共 23 条
  • [1] Utility of the FIESTA Pulse Sequence in Body Oncologic Imaging: Review
    Bhosale, Priya
    Ma, Jingfei
    Choi, Haesun
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (06) : S83 - S93
  • [2] High-Spatial and High-Temporal Resolution Dynamic Contrast-Enhanced Perfusion Imaging of the Liver with Time-Resolved Three-Dimensional Radial MRI
    Brodsky, Ethan K.
    Bultman, Eric M.
    Johnson, Kevin M.
    Horng, Debra E.
    Schelman, William R.
    Block, Walter F.
    Reeder, Scott B.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (03) : 934 - 941
  • [3] Effects of refocusing flip angle modulation and view ordering in 3D fast spin echo
    Busse, Reed F.
    Brau, Anja C. S.
    Vu, Anthony
    Michelich, Charles R.
    Bayram, Ersin
    Kijowski, Richard
    Reeder, Scott B.
    Rowley, Howard A.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (03) : 640 - 649
  • [4] Magnetic Resonance Imaging of Focal Liver Lesions: Approach to Imaging Diagnosis
    Fowler, Kathryn J.
    Brown, Jeffrey J.
    Narra, Vamsi R.
    [J]. HEPATOLOGY, 2011, 54 (06) : 2227 - 2237
  • [5] Learning a variational network for reconstruction of accelerated MRI data
    Hammernik, Kerstin
    Klatzer, Teresa
    Kobler, Erich
    Recht, Michael P.
    Sodickson, Daniel K.
    Pock, Thomas
    Knoll, Florian
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (06) : 3055 - 3071
  • [6] Multiecho sequences with variable refocusing flip angles: Optimization of signal behavior using smooth transitions between pseudo steady states (TRAPS)
    Hennig, J
    Weigel, M
    Scheffler, K
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (03) : 527 - 535
  • [7] Diagnostic Confidence and Feasibility of a Deep Learning Accelerated HASTE Sequence of the Abdomen in a Single Breath-Hold
    Herrmann, Judith
    Gassenmaier, Sebastian
    Nickel, Dominik
    Arberet, Simon
    Afat, Saif
    Lingg, Andreas
    Kundel, Matthias
    Othman, Ahmed E.
    [J]. INVESTIGATIVE RADIOLOGY, 2021, 56 (05) : 313 - 319
  • [8] Variable refocusing flip angle single-shot fast spin echo imaging of liver lesions: increased speed and lesion contrast
    Hicks, Robert M.
    Loening, Andreas M.
    Ohliger, Michael A.
    Vasanawala, Shreyas S.
    Hope, Thomas A.
    [J]. ABDOMINAL RADIOLOGY, 2018, 43 (03) : 593 - 599
  • [9] Improved Detection of Hepatic Metastases From Pancreatic Cancer Using Periodically Rotated Overlapping Parallel Lines With Enhanced Reconstruction (PROPELLER) Technique After SPIO Administration
    Hirokawa, Yuusuke
    Isoda, Hiroyoshi
    Okada, Tomohisa
    Arizono, Shigeki
    Shimada, Kotaro
    Yamamoto, Akira
    Shibata, Toshiya
    Togashi, Kaori
    [J]. INVESTIGATIVE RADIOLOGY, 2010, 45 (03) : 158 - 164
  • [10] Hepatic Lesions: Improved Image Quality and Detection with the Periodically Rotated Overlapping Parallel Lines with Enhanced Reconstruction Technique-Evaluation of SPIO-enhanced T2-weighted MR Images
    Hirokawa, Yuusuke
    Isoda, Hiroyoshi
    Maetani, Yoji S.
    Arizono, Shigeki
    Shimada, Kotaro
    Okada, Tomohisa
    Shibata, Toshiya
    Togashi, Kaori
    [J]. RADIOLOGY, 2009, 251 (02) : 388 - 397