Pattern electroretinogram association with spectral domain-OCT structural measurements in glaucoma

被引:27
作者
Bowd, C. [1 ]
Tafreshi, A. [1 ]
Zangwill, L. M. [1 ]
Medeiros, F. A. [1 ]
Sample, P. A. [1 ]
Weinreb, R. N. [1 ]
机构
[1] Univ Calif San Diego, Dept Ophthalmol, Hamilton Glaucoma Ctr, La Jolla, CA 92037 USA
关键词
glaucoma; electrophysiology; pattern electroretinogram; spectral domain; fourier domain; optical coherence tomography; OPTICAL COHERENCE TOMOGRAPHY; SCANNING LASER POLARIMETRY; GANGLION-CELL FUNCTION; OPEN-ANGLE GLAUCOMA; OCULAR HYPERTENSION; PRIMATE ELECTRORETINOGRAM; INTRAOCULAR-PRESSURE; NERVE; PARADIGM; ERG;
D O I
10.1038/eye.2010.203
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To describe the association between pattern electroretinogram (PERG) amplitude and spectral domain-optical coherence tomography (SD-OCT) macular thickness, retinal nerve fibre layer (RNFL) thickness and optic disc topography measurements. Subjects and methods Both eyes (n = 132) of 66 glaucoma patients (mean age = 67.9 years) enroled in the University of California, San Diego, CA, USA, Diagnostic Innovations in Glaucoma Study (DIGS) were included. Eyes were tested with PERG (Glaid PERGLA, Lace Elettronica, Pisa, Italy), RTVue SD-OCT (Optovue Inc., Fremont, CA, USA) GCC, and NHM4 protocols on the same day. Of the 66 enroled patients, 43 had glaucoma defined by repeated abnormal standard automated perimetry (SAP) results in at least one eye and 23 were glaucoma suspects defined by a glaucomatous-appearing optic disc by physicians' examination in at least one eye and normal SAP results in both eyes. Associations (R(2)) were determined between PERG amplitude (mu V) and SD-OCT macular ganglion cell complex (GCC) thickness (mu m), macular thickness (mu m), macular outer retinal thickness (macular thickness minus GCC thickness) (mu m), RNFL thickness (mu m), neuroretinal rim area (mm(2)), and rim volume (mm(3)). Results PERG amplitude was significantly associated with GCC thickness (R(2) = 0.179, P < 0.001), RNFL thickness (R(2) = 0.174, P < 0.001), and macular thickness (R(2) = 0.095, P < 0.001). R(2) associations with other parameters were not significant (all P > 0.624). Significant associations remained for GCC and average RNFL thickness when age and intraocular pressure at the time of testing were included in multivariate models (both P <= 0.030). Conclusions PERG amplitude is significantly (but weakly) associated with macular GCC thickness, RNFL thickness, and macular thickness. The lack of association between PERG amplitude and macular outer retinal thickness supports previous results, possibly suggesting that that the PERG is driven primarily by retinal ganglion cell (inner retinal) responses. Eye (2011) 25, 224-232; doi:10.1038/eye.2010.203; published online 24 December 2010
引用
收藏
页码:224 / 232
页数:9
相关论文
共 34 条
  • [1] Anderson DR, 1998, AUTOMATED STATIC PER, V2nd
  • [2] Bach M, 1993, Ger J Ophthalmol, V2, P178
  • [3] BACH M, 2006, PRINCIPLES PRACTICE
  • [4] The influence of ambient room lighting on the pattern electroretinogram (PERG)
    Bach M.
    Schumacher M.
    [J]. Documenta Ophthalmologica, 2002, 105 (3) : 281 - 289
  • [5] CURRENT SOURCE DENSITY ANALYSIS OF LINEAR AND NON-LINEAR COMPONENTS OF THE PRIMATE ELECTRORETINOGRAM
    BAKER, CL
    HESS, RR
    OLSEN, BT
    ZRENNER, E
    [J]. JOURNAL OF PHYSIOLOGY-LONDON, 1988, 407 : 155 - 176
  • [6] Bomer TG, 1996, GER J OPHTHALMOL, V5, P26
  • [7] Retinal nerve fiber layer thickness and visual sensitivity using scanning laser polarimetry with variable and enhanced corneal compensation
    Bowd, Christopher
    Tavares, Ivan M.
    Medeiros, Felipe A.
    Zangwill, Linda M.
    Sample, Pamela A.
    Weinreb, Robert N.
    [J]. OPHTHALMOLOGY, 2007, 114 (07) : 1259 - 1265
  • [8] Structure-function relationships using confocal scanning laser ophthalmoscopy, optical coherence tomography, and scanning laser polarimetry
    Bowd, Christopher
    Zangwill, Linda M.
    Medeiros, Felipe A.
    Tavares, Ivan M.
    Hoffmann, Esther M.
    Bourne, Rupert R.
    Sample, Pamela A.
    Weinreb, Robert N.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (07) : 2889 - 2895
  • [9] Repeatability of Pattern Electroretinogram Measurements Using a New Paradigm Optimized for Glaucoma Detection
    Bowd, Christopher
    Tafreshi, Ali
    Vizzeri, Gianmarco
    Zangwill, Linda M.
    Sample, Pamela A.
    Weinreb, Robert N.
    [J]. JOURNAL OF GLAUCOMA, 2009, 18 (06) : 437 - 442
  • [10] CAPRIOLI J, 1988, OPHTHALMOLOGY, V95, P723