In vitro and in vivo corrosion and histocompatibility of pure Mg and a Mg-6Zn alloy as urinary implants in rat model

被引:60
作者
Zhang, Shiying [1 ,3 ]
Zheng, Yang [2 ,3 ]
Zhang, Liming [1 ]
Bi, Yanze [2 ,3 ]
Li, Jianye [1 ]
Liu, Jiao [2 ,3 ]
Yu, Youbin [1 ]
Guo, Heqing [1 ]
Li, Yan [2 ,4 ]
机构
[1] Air Force Gen Hosp, Dept Urol, 30 Fucheng Rd, Beijing 100142, Peoples R China
[2] Beihang Univ, Sch Mat Sci & Engn, Beijing 100191, Peoples R China
[3] Beihang Univ, Minist Educ, Key Lab Aerosp Adv Mat & Performance, Beijing 100191, Peoples R China
[4] Beihang Univ, Beijing Key Lab Adv Funct Mat & Thin Film Technol, Beijing 100191, Peoples R China
来源
MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS | 2016年 / 68卷
基金
新加坡国家研究基金会; 中国国家自然科学基金;
关键词
Magnesium alloy; Degradation; In vivo histocompatibility; Urinary implants; MECHANICAL-PROPERTIES; ZN; BEHAVIOR; MICROSTRUCTURE; DEGRADATION; PERFORMANCE; SURFACE; MG-3ZN; CA;
D O I
10.1016/j.msec.2016.06.017
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
Pure Mg and a Mg-6 wt.% Zn alloy were investigated as potential candidates for biodegradable implants for the urinary system. The in vitro corrosion behavior was studied by potentiodynamic polarization and immersion tests in simulated body fluid (SBF) at 37 degrees C. The in vivo degradation and histocompatibility were examined through implantation into the bladders of Wistar rats. The alloying element Zn elevated the passivation potential and increased the cathodic current density. Both in vitro and in vivo degradation tests showed a faster corrosion rate for the Mg-6Zn alloy. Tissues stained with hematoxylin and eosin (HE) suggested that both pure Mg and Mg6-Zn alloy exhibited good histocompatibility in the bladder indwelling implantation and no differences between pure Mg and Mg-6Zn groups were found in bladder, liver and kidney tissues during the 2 weeks implantation. Overall, this work presented instructive information on the degradation properties and histocompatibility of pure Mg and the Mg-6Zn alloy in the urinary system. (C) 2016 Elsevier B.V. All, rights reserved.
引用
收藏
页码:414 / 422
页数:9
相关论文
共 41 条
[1]   What is the Best Technique for Urethroplasty? [J].
Andrich, Daniela E. ;
Mundy, Anthony R. .
EUROPEAN UROLOGY, 2008, 54 (05) :1031-1041
[2]  
[Anonymous], 2013, Standard test methods for density of compacted or sintered powder metallurgy (PM) products using archimedes ' principle, P1, DOI [DOI 10.1520/C1585-13.2, DOI 10.1520/C1585-20, 10.1520/C1585-13.2]
[3]  
[Anonymous], EUR UROL S
[4]  
[Anonymous], J UROL
[5]  
[Anonymous], LANCET
[6]   Effects of organic inhibitors on corrosion of zinc in an aerated 0.5 M NaCl solution [J].
Aramaki, K .
CORROSION SCIENCE, 2001, 43 (10) :1985-2000
[7]   Microstructure and mechanical properties of sintered porous magnesium using polymethyl methacrylate as the space holder [J].
Bi, Yanze ;
Zheng, Yang ;
Li, Yan .
MATERIALS LETTERS, 2015, 161 :583-586
[8]   Effects of Zn on microstructure, mechanical properties and corrosion behavior of Mg-Zn alloys [J].
Cai, Shuhua ;
Lei, Ting ;
Li, Nianfeng ;
Feng, Fangfang .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2012, 32 (08) :2570-2577
[9]   In vitro and in vivo corrosion measurements of Mg-6Zn alloys in the bile [J].
Chen, Yigang ;
Yan, Jun ;
Wang, Zhigang ;
Yu, Song ;
Wang, Xiaohu ;
Yuan, Ziming ;
Zhang, Xiaonong ;
Zhao, Changli ;
Zheng, Qi .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2014, 42 :116-123
[10]   Effect of microalloying with Ca on the microstructure and mechanical properties of Mg-6 mass%Zn alloys [J].
Du, Y. Z. ;
Qiao, X. G. ;
Zheng, M. Y. ;
Wang, D. B. ;
Wu, K. ;
Golovin, I. S. .
MATERIALS & DESIGN, 2016, 98 :285-293