Contamination-free sounding rocket Langmuir probe

被引:44
作者
Amatucci, WE [1 ]
Schuck, PW [1 ]
Walker, DN [1 ]
Kintner, PM [1 ]
Powell, S [1 ]
Holback, B [1 ]
Leonhardt, D [1 ]
机构
[1] USN, Res Lab, Div Plasma Phys, Washington, DC 20375 USA
关键词
D O I
10.1063/1.1357234
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A technique for removing surface contaminants from a sounding rocket spherical Langmuir probe is presented. Contamination layers present on probe surfaces can skew the collected data, resulting in the incorrect determination of plasma parameters. Despite following the usual probe cleaning techniques that are used prior to a launch, the probe surface can become coated with layers of adsorbed neutral gas in less than a second when exposed to atmosphere. The laboratory tests reported here show that by heating the probe from the interior using a small halogen lamp, adsorbed neutral particles can be removed from the probe surface, allowing accurate plasma parameter measurements to be made. (C) 2001 American Institute of Physics.
引用
收藏
页码:2052 / 2057
页数:6
相关论文
共 21 条
[1]   Velocity-shear-driven ion-cyclotron waves and associated transverse ion heating [J].
Amatucci, WE ;
Walker, DN ;
Ganguli, G ;
Duncan, D ;
Antoniades, JA ;
Bowles, JH ;
Gavrishchaka, V ;
Koepke, ME .
JOURNAL OF GEOPHYSICAL RESEARCH-SPACE PHYSICS, 1998, 103 (A6) :11711-11724
[2]   SELF-CLEANING LANGMUIR PROBE [J].
AMATUCCI, WE ;
KOEPKE, ME ;
SHERIDAN, TE ;
ALPORT, MJ ;
CARROLL, JJ .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (05) :1253-1256
[3]   HIGH-STABILITY TITANIUM NITRIDE BASED SOLAR CONTROL FILMS [J].
ANDERSSON, KE ;
WAHLSTROM, MK ;
ROOS, A .
THIN SOLID FILMS, 1992, 214 (02) :213-218
[4]  
Brace LH, 1998, GEOPH MONOG SERIES, V102, P23
[5]   EXPERIMENTAL-STUDY OF INFLUENCE OF SURFACE-POTENTIAL VARIATIONS ON MEASUREMENT OF ELECTRON-TEMPERATURE OF A PLASMA BY AN ELECTROSTATIC-PROBE [J].
BUJOR, M .
JOURNAL OF APPLIED PHYSICS, 1977, 48 (10) :4202-4209
[6]   DISCREPANCY IN ELECTRON TEMPERATURES DEDUCED FROM LANGMUIR PROBES AND FROM INCHORENT SCATTER RADARS [J].
CARLSON, HC ;
SAYERS, J .
JOURNAL OF GEOPHYSICAL RESEARCH, 1970, 75 (25) :4883-+
[7]   THE EFFECT OF A-SI-H THIN-FILM LAYERS ON THE DETERMINATION OF PLASMA PARAMETERS IN AN ELECTROSTATIC DOUBLE-PROBE MEASUREMENT [J].
CHANG, JS ;
ONO, S ;
TEII, S .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1991, 24 (08) :1310-1315
[8]  
CHEN FF, PLASMA DIAGNOSTIC TE
[9]  
HERSHKOWITZ N, PLASMA DIAGNOSTICS
[10]   CRITICAL STUDY ON RELIABILITY OF ELECTRON-TEMPERATURE MEASUREMENTS WITH A LANGMUIR PROBE [J].
HIRAO, K ;
OYAMA, K .
JOURNAL OF GEOMAGNETISM AND GEOELECTRICITY, 1972, 24 (04) :415-427