Construction of an anion-selective electrode:: Dichromate-selective electrode

被引:23
作者
Ertueruen, H. Elif Kormali
Yilmaz, Mustafa
Kilic, Esma [1 ]
机构
[1] Ankara Univ, Fen Fak, Dept Chem, Kimya Bolumu, TR-06100 Ankara, Turkey
[2] Selcuk Univ, Fac Arts & Sci, Dept Chem, Konya, Turkey
关键词
dichromate; ion-selective electrode; calix[4]arene; potentiometry;
D O I
10.1016/j.snb.2007.05.003
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The construction, performance and application of dichromate-selective PVC membrane electrodes based on 5,11,17,23-tetra-tert-butyl-25,27,-bis-(isoniazidylcarbonylmethoxy)-26,28-dihydroxycalix[4]arene are reported in this study. An optimum membrane composition of 2% ionophore, 68.3 mol% plasticizer, 29.7 mol% PVC and 60 mol% lipophilic additive with respect to the ionophere is found for the proposed electrodes. The influences of the plasticizer, polimer, lipophilic additives, pH of test solutions, internal filling solutions and thickness of membrane on the potentiometric response of electrodes are investigated. The electrode exhibits linear response of the dichromate ions in the concentration range of 1.0 x 10(-1) to 1.0 x 10(-7) M with 4.3 x 10(-8) M detection limit at pH 1.0. The slope of the calibration curve is 41.5 +/- 0.2 mV/decade. The proposed electrode shows good selectivity for dichromate ions in presence of some metal cations and anions. The electrode has a response time about 15-20 s and it can be used at least for 14 months with good reproducibility and repeatibility. The redox titrations involving dichromate as a titrant are monitored with the sensor, and iron(II) in pharmaceutical preperations is determined. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:497 / 504
页数:8
相关论文
共 32 条
[1]   Chromium(III) ion-selective electrode based on 4-dimethylaminoazobenzene [J].
Abbaspour, A ;
Izadyar, A .
TALANTA, 2001, 53 (05) :1009-1013
[2]  
Antonisse MMG, 1999, ELECTROANAL, V11, P1035, DOI 10.1002/(SICI)1521-4109(199910)11:14<1035::AID-ELAN1035>3.0.CO
[3]  
2-I
[4]  
ARDAKANI MM, 2005, MICROCHIM ACTA, V150, P67, DOI DOI 10.1007/S00604-005-0319-6
[5]  
Bakker E, 1999, ELECTROANAL, V11, P915, DOI 10.1002/(SICI)1521-4109(199909)11:13<915::AID-ELAN915>3.0.CO
[6]  
2-J
[7]   Ionophore-based membrane electrodes: new analytical concepts and non-classical response mechanisms [J].
Bakker, E ;
Meyerhoff, ME .
ANALYTICA CHIMICA ACTA, 2000, 416 (02) :121-137
[8]   RECOMMENDATIONS FOR NOMENCLATURE OF ION-SELECTIVE ELECTRODES - (IUPAC RECOMMENDATIONS 1994) [J].
BUCK, RP ;
LINDNER, E .
PURE AND APPLIED CHEMISTRY, 1994, 66 (12) :2527-2536
[9]  
Burrows D, 1983, CHROMIUM METABOLISM, P172
[10]  