Vibrotactile guidance for trajectory following in Computer Aided Surgery

被引:6
作者
Bluteau, Jeremy [1 ,2 ,3 ]
Dubois, Marie-Dominique [4 ]
Coquillart, Sabine [2 ]
Gentaz, Edouard [3 ]
Payan, Yohan [1 ]
机构
[1] Fac Med, TIMC Lab, Pavillon Taillefer, F-38706 La Tronche, France
[2] INRIA Grenoble Rhone Alpes, LIG, F-38330 Saint Ismier, France
[3] Grenoble Univ, LPNC Lab, F-38400 Saint martin heres, France
[4] CHU Saint Etienne, ENT Dept, Hopital Nord, F-42000 St Etienne, France
来源
2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC) | 2010年
关键词
TACTILE DISPLAY;
D O I
10.1109/IEMBS.2010.5626270
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Most conventional computer-aided navigation systems assist the surgeon visually by tracking the position of an ancillary and by superposing this position into the 3D preoperative imaging exam. This paper aims at adding to such navigation systems a device that will guide the surgeon towards the target, following a complex preplanned ancillary trajectory. We propose to use tactile stimuli for such guidance, with the design of a vibrating belt. An experiment using a virtual surgery simulator in the case of skull base surgery is conducted with 9 naive subjects, assessing the vibrotactile guidance effectiveness for complex trajectories. Comparisons between a visual guidance and a visual+tactile guidance are encouraging, supporting the relevance of such tactile guidance paradigm.
引用
收藏
页码:2085 / 2088
页数:4
相关论文
共 11 条
[1]  
BLUTEAU J, 2010, THESIS GRENOBLE U FR
[2]  
Brell M, 2008, LECT NOTES COMPUT SC, V5024, P383, DOI 10.1007/978-3-540-69057-3_50
[3]  
ERIKSSON M, 2005, P WORLD HAPT MARCH P
[4]  
GEORGE AP, 2009, J LARYNGOL OTOL, V1, P1
[5]  
Merloz P, 1998, Comput Aided Surg, V3, P297, DOI 10.3109/10929089809148150
[6]   Visuohaptic simulation of bone surgery for training and evaluation [J].
Morris, Dan ;
Sewell, Christopher ;
Barbagli, Federico ;
Salisbury, Kenneth ;
Blevins, Nikolas H. ;
Girod, Sabine .
IEEE COMPUTER GRAPHICS AND APPLICATIONS, 2006, 26 (06) :48-57
[7]   Computer-assisted access to the kidney [J].
Mozer, P ;
Leroy, A ;
Payan, Y ;
Troccaz, J ;
Chartier-Kastier, E ;
Richard, F .
INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2005, 1 (04) :58-66
[8]   Evaluation of a Tactile Display Around the Waist for Physiological Monitoring under Different Clinical Workload Conditions [J].
Ng, G. ;
Barralon, P. ;
Schwarz, S. K. W. ;
Dumont, G. ;
Ansermino, J. M. .
2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, :1288-+
[9]  
ROBINEAU F, 2009, THESIS U J FOURIER F
[10]  
ROBINEAU F, 2007, IEEE T BIOMEDICAL EN, V54