Comparison of dimensional accuracy between direct-printed and thermoformed aligners

被引:30
作者
Koenig, Nickolas [1 ]
Choi, Jin-Young [2 ]
McCray, Julie [1 ]
Hayes, Andrew [1 ]
Schneider, Patricia [1 ]
Kim, Ki Beom [1 ]
机构
[1] St Louis Univ, Dept Orthodont, 3320 Ringer St, St Louis, MO 63104 USA
[2] Kyung Hee Univ, Grad Sch Dent, Dept Orthodont, Seoul, South Korea
关键词
Aligner; Physical property; Resin; Three-dimensional scanner; CLEAR; RETAINERS; MODELS; FIT;
D O I
10.4041/kjod21.269
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: The purpose of this study was to evaluate and compare the dimensional accuracy between thermoformed and direct-printed aligners. Methods: Three types of aligners were manufactured from the same reference standard tessellation language (STL) file: thermoformed aligners were manufactured using Zendura FLXTM(n = 12) and Essix ACETM (n = 12), and direct-printed aligners were printed using Tera HarzTM TC-85DAP 3D Printer UV Resin (n = 12). The teeth were not manipulated with any tooth-moving software in this study. The samples were sprayed with an opaque scanning spray, scanned, imported to Geomagic (R) Control XTM metrology software, and superimposed on the reference STL file by using the best-fit alignment algorithm. Distances between the aligner meshes and the reference STL file were measured at nine anatomical landmarks. Results: Mean absolute discrepancies in the Zendura FLXTM aligners ranged from 0.076 +/- 0.057 mm to 0.260 +/- 0.089 mm and those in the Essix ACETM aligners ranged from 0.188 +/- 0.271 mm to 0.457 +/- 0.350 mm, while in the direct-printed aligners, they ranged from 0.079 +/- 0.054 mm to 0.224 +/- 0.041 mm. Root mean square values, representing the overall trueness, ranged from 0.209 +/- 0.094 mm for Essix ACETM, 0.188 +/- 0.074 mm for Zendura FLXTM, and 0.140 +/- 0.020 mm for the direct-printed aligners. Conclusions: This study showed greater trueness and precision of direct-printed aligners than thermoformed aligners.
引用
收藏
页码:249 / 257
页数:9
相关论文
共 42 条
  • [31] Comparison of Three-Dimensional Accuracy of Digital and Conventional Implant Impressions: Effect of Interimplant Distance in an Edentulous Arch
    Tan, Ming Yi
    Yee, Sophia Hui Xin
    Wong, Keng Mun
    Tan, Ying Han
    Tan, Keson Beng Choon
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (02) : 366 - 380
  • [32] A direct comparison of the diagnostic accuracy of three prostate cancer nomograms designed to predict the likelihood of a positive initial transrectal biopsy
    Ouzaid, Idir
    Yates, David R.
    Hupertan, Vincent
    Mozer, Pierre
    Chartier-Kastler, Emmanuel
    Haertig, Alain
    Bitker, Marc-Olivier
    Roupret, Morgan
    PROSTATE, 2012, 72 (11) : 1200 - 1206
  • [33] Accuracy and reliability comparison between different intraoral scanning devices in patients with permanent dentition: A prospective clinical study
    Cavalcanti, Heloisa Nelson
    Lazaro, Vinicius Ribeiro de Almeida
    da Silva, Vinicius Merino
    Bellini-Pereira, Silvio Augusto
    Janson, Guilherme
    Garib, Daniela
    Henriques, Jose Fernando Castanha
    INTERNATIONAL ORTHODONTICS, 2025, 23 (02)
  • [34] Predicting manual arm strength: A direct comparison between artificial neural network and multiple regression approaches
    La Delfa, Nicholas J.
    Potvin, Jim R.
    JOURNAL OF BIOMECHANICS, 2016, 49 (04) : 602 - 605
  • [35] Direct Comparison Between a Non-Orographic Gravity Wave Drag Scheme and Constant Level Balloons
    Lott, F.
    Rani, R.
    Podglajen, A.
    Codron, F.
    Guez, L.
    Hertzog, A.
    Plougonven, R.
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2023, 128 (04)
  • [36] Comparison between two- and three-dimensional scoring of zebrafish response to psychoactive drugs: identifying when three-dimensional analysis is needed
    Macri, Simone
    Clement, Romain J. G.
    Spinello, Chiara
    Porfiri, Maurizio
    PEERJ, 2019, 7
  • [37] Direct comparison of PDF and scalar dissipation rates between LEM simulations and experiments for turbulent, premixed methane air flames
    Tsui, H. P.
    Kamal, M. M.
    Hochgreb, S.
    Bushe, W. K.
    COMBUSTION AND FLAME, 2016, 165 : 208 - 222
  • [38] Comparison of fracture resistance between cast, CAD/CAM milling, and direct metal laser sintering metal post systems
    Bilgin, Mehmet Selim
    Erdem, Ali
    Dilber, Erhan
    Ersoy, Ibrahim
    JOURNAL OF PROSTHODONTIC RESEARCH, 2016, 60 (01) : 23 - 28
  • [39] Comparison of Fit and Stability Between 3D-Printed and Milled Implant Abutments with Titanium-6Al-4V and Co-Cr Metal Alloys
    Yoo, Soo-Yeon
    Kim, Seong-Kyun
    Heo, Seong-Joo
    Koak, Jai-Young
    Park, Ji-Man
    Chung, Shin Hye
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2023, 38 (05) : 1014 - 1024
  • [40] Exposure of the SH-SY5Y Human Neuroblastoma Cells to 50-Hz Magnetic Field: Comparison Between Two-Dimensional (2D) and Three-Dimensional (3D) In Vitro Cultures
    Consales, Claudia
    Butera, Alessio
    Merla, Caterina
    Pasquali, Emanuela
    Lopresto, Vanni
    Pinto, Rosanna
    Pierdomenico, Maria
    Mancuso, Mariateresa
    Marino, Carmela
    Benassi, Barbara
    MOLECULAR NEUROBIOLOGY, 2021, 58 (04) : 1634 - 1649