Catalytic activity of iron hexacyanoosmate(II) towards hydrogen peroxide and nicotinamide adenine dinucleotide and its use in amperometric biosensors

被引:17
作者
Kotzian, Petr
Janku, Tereza
Kalcher, Kurt
Vytras, Karel
机构
[1] Univ Pardubice, Dept Analyt Chem, CZ-53210 Pardubice, Czech Republic
[2] Karl Franzens Univ Graz, Inst Chem Analyt Chem, A-8010 Graz, Austria
关键词
screen-printed electrodes; biosensor; osmium purple; ruthenium purple; Prussian blue; hydrogen peroxide; glucose; ethanol; flow injection analysis;
D O I
10.1016/j.aca.2007.07.053
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Hydrogen peroxide and nicotinamide adenine dinucleotide (NADH) may be determined amperometrically using screen-printed electrodes chemically modified with iron(III) hexacyanoosmate(II) (Osmium purple) in flow injection analysis (FIA). The determination is based on the exploitation of catalytic currents resulting from the oxidation/reduction of the modifier. The performance of the sensor was characterized and optimized by controlling several operational parameters (applied potential, pH and flow rate of the phosphate buffer). Comparison has been made with analogous complexes of ruthenium (Ruthenium purple) and iron (Prussian blue). Taking into account the sensitivity and stability of corresponding sensors, the best results were obtained with the use of Osmium purple. The sensor exhibited a linear increase of the amperometric signal with the concentration of hydrogen peroxide in the range of 0.1-100 mg L-1 with a detection limit (evaluated as 3 sigma) of 0.024 mg L-1 with a R.S.D. 1.5% for 10 mg L-1 H2O2 under optimized flow rate of 0.4 mL min(-1) in 0.1 M phosphate buffer carrier (pH 6) and a working potential of +0.15 V versus Ag/AgCl. Afterwards, a biological recognition element - either glucose oxidase or ethanol dehydrogenase - was incorporated to achieve a sensor facilitating the determination of glucose or ethanol, respectively. The glucose sensor gave linearity between current and concentration in the range from 1 to 250 mg L-1 with a R.S.D. 2.4% for 100 mg L-1 glucose, detection limit 0.02 mg L-1 (3 sigma) and retained its original activity after 3 weeks when stored at 6 degrees C. Optimal parameters in the determination of ethanol were selected as: applied potential +0.45 V versus Ag/AgCl, flow rate 0.2 mL min(-1) in 0.1 M phosphate buffer carrier (pH 7). Different structural designs of the ethanol sensor were tested and linearity obtained was up to 1000 mg L-1 with a maximum R.S.D. of 5.1%. Applications in food analysis were also examined. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:287 / 293
页数:7
相关论文
共 22 条
[1]   (Bio)sensors based on manganese dioxide-modified carbon substrates: retrospections, further improvements and applications [J].
Beyene, NW ;
Kotzian, P ;
Schachl, K ;
Alemu, H ;
Turkusic, E ;
Copra, A ;
Moderegger, H ;
Svancara, I ;
Vytras, K ;
Kalcher, K .
TALANTA, 2004, 64 (05) :1151-1159
[2]   Hydrogen peroxide detection at electrochemically and sol-gel derived Ir oxide films [J].
Elzanowska, H ;
Abu-Irhayem, E ;
Skrzynecka, B ;
Birss, VI .
ELECTROANALYSIS, 2004, 16 (06) :478-490
[3]   Amperometric biosensors based on dehydrogenase/NAD and heterocyclic quinones [J].
Geng, L ;
Boguslavsky, LI ;
Kovalev, IP ;
Sahni, SK ;
Kalash, H ;
Skotheim, TA ;
Lee, HS ;
Laurinavicius, V .
BIOSENSORS & BIOELECTRONICS, 1996, 11 (12) :1267-1275
[4]   CARBON-PASTE ELECTRODES MODIFIED WITH ENZYMES, TISSUES, AND CELLS [J].
GORTON, L .
ELECTROANALYSIS, 1995, 7 (01) :23-45
[5]   BONDING NATURE AND SEMICONDUCTIVITY OF PRUSSIAN BLUE AND RELATED COMPOUNDS [J].
INOUE, H ;
YANAGISAWA, S .
JOURNAL OF INORGANIC & NUCLEAR CHEMISTRY, 1974, 36 (06) :1409-1411
[6]   Stabilization of an osmium bis-bipyridyl polymer-modified carbon paste amperometric glucose biosensor using polyethyleneimine [J].
Jezkova, J ;
Iwuoha, EI ;
Smyth, MR ;
Vytras, K .
ELECTROANALYSIS, 1997, 9 (13) :978-984
[7]   Catalytic electrooxidation of NADH for dehydrogenase amperometric biosensors [J].
Katakis, I ;
Dominguez, E .
MIKROCHIMICA ACTA, 1997, 126 (1-2) :11-32
[8]  
Keggin J.F., 1936, NATURE, V137, P577, DOI [10.1038/137577a0, DOI 10.1038/137577A0]
[9]   Determination of hydrogen peroxide, glucose and hypoxanthine using (bio) sensors based on ruthenium dioxide-modified screen-printed electrodes [J].
Kotzian, P ;
Brázdilová, P ;
Kalcher, K ;
Vytras, K .
ANALYTICAL LETTERS, 2005, 38 (07) :1099-1113
[10]  
KOTZIAN P, 2007, ACTUATORS B, V124, P297