Monitoring Cardiac Output and Left Atrial Pressure by Analysis of the Right Ventricular Pressure Waveform Based on Missing Output Identification

被引:1
|
作者
Xu, Da [1 ]
Olivier, N. Bari [2 ]
Mukkamala, Ramakrishna [1 ]
机构
[1] Michigan State Univ, Dept Elect & Comp Engn, E Lansing, MI 48824 USA
[2] Michigan State Univ, Dept Small Anim Clin Sci, E Lansing, MI 48824 USA
来源
2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20 | 2009年
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
IMPLANTABLE HEMODYNAMIC MONITOR; HEART-FAILURE; FEASIBILITY; MULTICENTER;
D O I
10.1109/IEMBS.2009.5332740
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A proven implantable device is now available for long-term ambulatory monitoring of the right ventricular pressure (RVP) waveform of congestive heart failure patients. However, cardiac output (CO) and left atrial pressure (LAP) are far more useful for assessing cardiac function and managing volume status. We developed a new technique to monitor both CO and LAP by analysis of the RVP waveform based on missing output identification. We initially evaluated the technique against gold standard reference CO and LAP measurements from two dogs during common hemodynamic interventions. We report overall CO and LAP errors of 13.3% and 1.9 mmHg, respectively. With further successful testing, the technique may potentially be employed with an established implantable device for chronic monitoring of vital hemodynamic variables.
引用
收藏
页码:4356 / +
页数:2
相关论文
共 50 条
  • [1] Cardiac Output and Left Atrial Pressure Monitoring by Right Ventricular Pressure Waveform Analysis for Potential Implantable Device Application
    Xu, Da
    Olivier, N. Bari
    Mukkamala, Ramakrishna
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2009, 56 (09) : 2335 - 2339
  • [2] Continuous cardiac output and left atrial pressure monitoring by pulmonary artery pressure waveform analysis
    Lu, Zhenwei
    Mukkamala, Ramakrishna
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 3574 - +
  • [3] Comparison Of Three Techniques For Continuous Cardiac Output And Left Atrial Pressure Monitoring By Pulmonary Artery Pressure Waveform Analysis
    Xu, D.
    Olivier, N. B.
    Mukkamala, R.
    ANALYSIS OF BIOMEDICAL SIGNALS AND IMAGES, 2008, : 17 - 19
  • [4] Continuous cardiac output and left atrial pressure monitoring by long time interval analysis of the pulmonary artery pressure waveform: proof of concept in dogs
    Xu, Da
    Olivier, N. Bari
    Mukkamala, Ramakrishna
    JOURNAL OF APPLIED PHYSIOLOGY, 2009, 106 (02) : 651 - 661
  • [5] Continuous cardiac output monitoring by peripheral blood pressure waveform analysis
    Mukkamala, R
    Reisner, AT
    Hojman, HM
    Mark, RG
    Cohen, RJ
    COMPUTERS IN CARDIOLOGY 2003, VOL 30, 2003, 30 : 255 - 258
  • [6] Continuous cardiac output monitoring by peripheral blood pressure waveform analysis
    Mukkamala, R
    Reisner, AT
    Hojman, HM
    Mark, RG
    Cohen, RJ
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2006, 53 (03) : 459 - 467
  • [7] Calculation Of Cardiac Power Output With Right Atrial Pressure
    Belkin, Mark N.
    Kalantari, Sara
    Kanelidis, Anthony J.
    Miller, Tamari
    Besser, Stephanie
    Nguyen, Ann
    Chung, Bow
    Smith, Bryan
    Sarswat, Nitasha
    Kim, Gene
    Pinney, Sean
    Grinstein, Jonathan
    JOURNAL OF CARDIAC FAILURE, 2022, 28 (05) : S89 - S89
  • [8] Monitoring cardiac output from the radial artery pressure waveform
    Orme, R. M. L'E.
    Pigott, D. W.
    ANAESTHESIA, 2007, 62 (01) : 90 - 91
  • [9] INFLUENCE OF LEFT-VENTRICULAR FILLING PRESSURE ON ATRIAL CONTRIBUTION TO CARDIAC-OUTPUT
    GREENBERG, B
    CHATTERJEE, K
    PARMLEY, WW
    WERNER, JA
    HOLLY, AN
    AMERICAN HEART JOURNAL, 1979, 98 (06) : 742 - 751
  • [10] Cardiac output monitoring in intensive care patients by radial artery pressure waveform analysis
    Mukkamala, R
    Kuiper, J
    Ahmad, S
    Lu, Z
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 3712 - 3715