Energy and comfort performance benefits of early detection of building sensor and actuator faults

被引:18
|
作者
Gunay, Burak [1 ]
Shen, Weiming [2 ]
Huchuk, Brent [3 ]
Yang, Chunsheng [2 ]
Bucking, Scott [1 ]
O'Brien, William [1 ]
机构
[1] Carleton Univ, Dept Civil & Environm Engn, 1125 Colonel By Dr, Ottawa, ON K1S 5B6, Canada
[2] Natl Res Council Canada, Ottawa, ON, Canada
[3] Univ Toronto, Dept Mech & Ind Engn, Toronto, ON, Canada
来源
BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY | 2018年 / 39卷 / 06期
基金
加拿大自然科学与工程研究理事会;
关键词
Fault detection and diagnostics; building performance simulation; energy and comfort impact of sensor and actuator faults; AIR-HANDLING UNITS; MODEL-PREDICTIVE CONTROL; OPERATION; DIAGNOSTICS; PROGNOSTICS; COMPLAINTS; SYSTEMS; ZONE;
D O I
10.1177/0143624418769264
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents a building performance simulation-based investigation to better understand the energy and comfort performance benefits of early detection of common sensor and actuator faults. Five types of air-handling unit faults and four types of zone-level faults were implemented to the energy management system application of the building performance simulation tool EnergyPlus. During 50-year simulation periods, the faults were randomly permitted to affect 75 different components of an archetype medium-sized office building model. The sensitivity of the simulation results with respect to three variables was studied: fault recurrence period, fault repair period, and discomfort threshold for simulated complaints. The results indicate that the energy use intensity and the predicted percentage of dissatisfied exhibit a power-law relationship with time, in which most of the performance reductions occur in the first 10 years. If the work-orders are issued only upon occupant complaints, the faults were estimated to cause a 16-62% increase in the energy use intensity for heating, ventilation, and air-conditioning and a 11-38% increase in the predicted percentage of dissatisfied at the end of the 50-year simulation periods. The results indicate that if the faults can be detected within a month after their first appearance, almost all their detrimental effects on a building's energy and comfort performance can be mitigated. Practical application: The methodology and results presented in this article are of practical use for those who study on-going commissioning, fault detection and diagnostics, and energy management systems in buildings. The simulation-based parametric analysis approach can be used to estimate the range of energy and comfort savings expected through early detection of common sensor and actuator faults in commercial buildings. Insights gathered from such an analysis can be used in planning the frequency of retro-commissioning and investments for automated fault detection and diagnostics systems.
引用
收藏
页码:652 / 666
页数:15
相关论文
共 50 条
  • [1] Robust Detection and Identification of Simultaneous Sensor and Actuator Faults
    El-Kebir, Hamza
    Ornik, Melkior
    Nakka, Yashwanth Kumar
    Choi, Changrak
    Rahmani, Amir
    2024 IEEE AEROSPACE CONFERENCE, 2024,
  • [2] Detection of Faults and Drifts in the Energy Performance of a Building Using Bayesian Networks
    Bigaud, David
    Charki, Abderafi
    Caucheteux, Antoine
    Titikpina, Fally
    Tiplica, Teodor
    JOURNAL OF DYNAMIC SYSTEMS MEASUREMENT AND CONTROL-TRANSACTIONS OF THE ASME, 2019, 141 (10):
  • [3] Detection and isolation of actuator and sensor faults for networked control systems
    Ahmadi, Ali-Akbar
    Salmasi, Farzad R.
    OPTIMAL CONTROL APPLICATIONS & METHODS, 2017, 38 (03): : 355 - 375
  • [4] Design of integrated systems for the control and detection of actuator/sensor faults
    Stoustrup, Jakob
    Grimble, M.J.
    Niemann, Henrik
    Sensor Review, 1997, 17 (02): : 138 - 149
  • [5] Dynamic Neural Network for Detection and Identification Actuator and Sensor Faults
    Dhaou, O.
    Sidhom, L.
    Abdelkrim, A.
    2018 INTERNATIONAL CONFERENCE ON ADVANCED SYSTEMS AND ELECTRICAL TECHNOLOGIES (IC_ASET), 2017, : 107 - 112
  • [6] Impacts of HVACR temperature sensor offsets on building energy performance and occupant thermal comfort
    Sungmin Yoon
    Yuebin Yu
    Jiaqiang Wang
    Peng Wang
    Building Simulation, 2019, 12 : 259 - 271
  • [7] Detection and Isolation of Process Faults from Actuator Faults and Sensor Faults for a Typical MIMO Dynamic System
    Lin, Paul P.
    Zhu, James H.
    11TH IEEE INTERNATIONAL CONFERENCE ON CONTROL AND AUTOMATION (ICCA), 2014, : 371 - 376
  • [8] Impacts of HVACR temperature sensor offsets on building energy performance and occupant thermal comfort
    Yoon, Sungmin
    Yu, Yuebin
    Wang, Jiaqiang
    Wang, Peng
    BUILDING SIMULATION, 2019, 12 (02) : 259 - 271
  • [9] Sliding mode observers for robust detection and reconstruction of actuator and sensor faults
    Tan, CP
    Edwards, C
    INTERNATIONAL JOURNAL OF ROBUST AND NONLINEAR CONTROL, 2003, 13 (05) : 443 - 463
  • [10] Extended multiple model adaptive estimation for the detection of sensor and actuator faults
    Rupp, D.
    Ducard, G.
    Shafai, E.
    Geering, H. P.
    2005 44th IEEE Conference on Decision and Control & European Control Conference, Vols 1-8, 2005, : 3079 - 3084