Quantitative assessment of myocardial perfusion during graded coronary stenosis by real-time myocardial contrast echo refilling curves

被引:97
作者
Masugata, H [1 ]
Peters, B [1 ]
Lafitte, S [1 ]
Strachan, GM [1 ]
Ohmori, K [1 ]
DeMaria, AN [1 ]
机构
[1] Univ Calif San Diego, Med Ctr, Div Cardiovasc, San Diego, CA 92103 USA
关键词
D O I
10.1016/S0735-1097(00)01046-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The present study examined the ability of real-time myocardial contrast echocardiography (MCE) to delineate abnormalities produced by graded coronary stenoses and to correlate signal intensity (SI) parameters derived from destruction/refilling curves with regional myocardial blood flow (MBF) and contractile function. BACKGROUND Recent technological advances have enabled myocardial opacification by MCE to be achieved during real-time imaging. METHODS In eight open-chest dogs, we created LAD occlusion and graded stenoses that were either flow-limiting at rest (FLS) or reduced adenosine hyperemia (non-flow-limiting at rest = NFLS). Myocardial contrast echo used Optison infusion and low-energy real-time power pulse inversion imaging. High-energy FLASH frames destroyed bubbles every 15 cardiac cycles. Myocardial SI-versus-time plots were fitted to a one-exponential function to obtain the rate of SI rise (b) and peak SI in the last frame. RESULTS Dyssynergy was not observed during any NFLS, but perfusion abnormalities were. Visual detection of decreased opacification was possible with severe NFLS and FLS. b demonstrated a significant reduction with severe NFLS and near significant with moderate NFLS; peak SI did not. All exponential parameters were significantly decreased with FL stenosis and occlusion. The MBF ratio in LAD/LCx beds (fluorescent microspheres) correlated with b (r = 0.79) and the product of the peak SI and b (r = 0.80). CONCLUSIONS In an open-chest dog model, parameters derived from microbubble refilling of the imaging field by real-time MCE correlate well with myocardial blood dow and can identify coronary stenosis. (J Am Coil Cardiol 2001;37:262-9) (C) 2001 by the American College of Cardiology.
引用
收藏
页码:262 / 269
页数:8
相关论文
共 50 条
[41]   Myocardial contrast echocardiography for assessment of myocardial perfusion at rest in a patient with left main coronary artery stenosis [J].
Hagendorff, A ;
Pfeiffer, D ;
Rother, T ;
Becher, H .
ZEITSCHRIFT FUR KARDIOLOGIE, 2003, 92 (10) :876-883
[42]   Assessment of myocardial perfusion: Can it be done using real-time 3D echo? [J].
Bhan, A. ;
Kapetanakis, S. ;
Rana, B. ;
Ho, E. ;
Wilson, K. ;
Monaghan, M. .
HEART, 2007, 93 :A76-A76
[43]   Real-time myocardial contrast echocardiography, perfusion quantitative analysis, and heterogeneity in hypertrophic obstructive cardiomyopathy [J].
Coucelo, JA ;
Soares, L ;
Azevedo, J ;
Silva, F ;
Arroja, I ;
Aleixo, A .
CIRCULATION, 2004, 110 (17) :678-678
[44]   Quantitative assessment of left ventricular perfusion defects using real-time three-dimensional myocardial contrast echocardiography [J].
Camarano, G ;
Jones, M ;
Freidlin, RZ ;
Panza, JA .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2002, 15 (03) :206-213
[45]   A Workstation for the Quantitative Analysis of Real-time Myocardial Contrast Echocardiography [J].
Sun, Feng-rong ;
Zhang, Ming-qiang ;
Jia, Xiao-bo ;
Yao, Gui-hua .
PROCEEDINGS OF THE 2009 2ND INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOLS 1-4, 2009, :122-+
[46]   Estimation of coronary artery stenosis by low-dose adenosine stress real-time myocardial contrast echocardiography: a quantitative study [J].
Zhou Xiao ;
Zhi Guang ;
Xu Yong ;
Wang Jing ;
Yan Guo-hui .
CHINESE MEDICAL JOURNAL, 2012, 125 (10) :1795-1798
[47]   Evaluation of regional myocardial perfusion in methamphetamine abusers using real-time myocardial contrast echocardiography [J].
Zheng, Xiao-Zhi ;
Shi, Yun-Yan ;
Chen, Ke-Qi ;
Qiao, Xiao-Ling ;
Wang, Lian-You .
MEDICAL ULTRASONOGRAPHY, 2019, 21 (01) :56-61
[48]   Assessment of coronary flow rate by contrast echo refilling curves: In vitro and in vivo studies [J].
Lafitte, S ;
Peter, B ;
Masugata, H ;
Togni, M ;
Strachan, M ;
Demaria, AN .
CIRCULATION, 2000, 102 (18) :540-541
[49]   A NEW METHOD FOR REAL-TIME ASSESSMENT OF REGIONAL MYOCARDIAL PERFUSION [J].
FEINSTEIN, SB ;
LANG, R ;
GEISER, E ;
POWSNER, S ;
NEUMANN, A ;
BOROW, KM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 7 (02) :A189-A189
[50]   Quantitative assessment of myocardial perfusion using real-time three-dimensional echocardiographic Imaging [J].
Toledo, E ;
Lang, RM ;
Collins, KA ;
Williams, U ;
Lammertin, G ;
Weinert, L ;
Mor-Avi, V .
Computers in Cardiology 2004, Vol 31, 2004, 31 :225-228