Quantitative assessment of myocardial perfusion during graded coronary stenosis by real-time myocardial contrast echo refilling curves

被引:97
作者
Masugata, H [1 ]
Peters, B [1 ]
Lafitte, S [1 ]
Strachan, GM [1 ]
Ohmori, K [1 ]
DeMaria, AN [1 ]
机构
[1] Univ Calif San Diego, Med Ctr, Div Cardiovasc, San Diego, CA 92103 USA
关键词
D O I
10.1016/S0735-1097(00)01046-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The present study examined the ability of real-time myocardial contrast echocardiography (MCE) to delineate abnormalities produced by graded coronary stenoses and to correlate signal intensity (SI) parameters derived from destruction/refilling curves with regional myocardial blood flow (MBF) and contractile function. BACKGROUND Recent technological advances have enabled myocardial opacification by MCE to be achieved during real-time imaging. METHODS In eight open-chest dogs, we created LAD occlusion and graded stenoses that were either flow-limiting at rest (FLS) or reduced adenosine hyperemia (non-flow-limiting at rest = NFLS). Myocardial contrast echo used Optison infusion and low-energy real-time power pulse inversion imaging. High-energy FLASH frames destroyed bubbles every 15 cardiac cycles. Myocardial SI-versus-time plots were fitted to a one-exponential function to obtain the rate of SI rise (b) and peak SI in the last frame. RESULTS Dyssynergy was not observed during any NFLS, but perfusion abnormalities were. Visual detection of decreased opacification was possible with severe NFLS and FLS. b demonstrated a significant reduction with severe NFLS and near significant with moderate NFLS; peak SI did not. All exponential parameters were significantly decreased with FL stenosis and occlusion. The MBF ratio in LAD/LCx beds (fluorescent microspheres) correlated with b (r = 0.79) and the product of the peak SI and b (r = 0.80). CONCLUSIONS In an open-chest dog model, parameters derived from microbubble refilling of the imaging field by real-time MCE correlate well with myocardial blood dow and can identify coronary stenosis. (J Am Coil Cardiol 2001;37:262-9) (C) 2001 by the American College of Cardiology.
引用
收藏
页码:262 / 269
页数:8
相关论文
共 50 条
  • [31] Quantitative analysis of myocaridal perfusion in rabbits by tansthoracic real-time myocardial contrast echocardiography
    Heping Deng
    Mingxing Xie
    Xinfang Wang
    Qing Lv
    Songnan Li
    Yuting Bao
    Jing Wang
    Xiaofang Lu
    Yali Yang
    Bo Lu
    [J]. Journal of Huazhong University of Science and Technology [Medical Sciences], 2009, 29 : 795 - 799
  • [32] Quantitative Analysis of Myocaridal Perfusion in Rabbits by Tansthoracic Real-time Myocardial Contrast Echocardiography
    邓荷萍
    谢明星
    王新房
    吕清
    李松南
    鲍玉婷
    王静
    卢晓芳
    杨亚利
    陆博
    [J]. Journal of Huazhong University of Science and Technology(Medical Sciences), 2009, 29 (06) : 795 - 799
  • [33] Assessment of myocardial perfusion using real-time myocardial contrast echocardiography and dobutamine stress echocardiography in patients after percutaneous coronary intervention
    Shu, X. H.
    Pan, C. Z.
    Guo, S. Z.
    Ruan, W.
    Ge, J. B.
    Chen, H. Z.
    [J]. EUROPEAN HEART JOURNAL, 2006, 27 : 714 - 715
  • [34] Qualitative angiographic and quantitative myocardial perfusion assessment using fluorescent cardiac imaging during graded coronary artery bypass stenosis
    Christian Detter
    Detlef Russ
    Jan Felix Kersten
    Hermann Reichenspurner
    Sabine Wipper
    [J]. The International Journal of Cardiovascular Imaging, 2018, 34 : 159 - 167
  • [35] Qualitative angiographic and quantitative myocardial perfusion assessment using fluorescent cardiac imaging during graded coronary artery bypass stenosis
    Detter, Christian
    Russ, Detlef
    Kersten, Jan Felix
    Reichenspurner, Hermann
    Wipper, Sabine
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2018, 34 (02) : 159 - 167
  • [36] Quantitative assessment of cardiac allograft vasculopathy by real-time myocardial contrast echocardiography
    Uebleis, C.
    Hoyer, X.
    Ueberfuhr, P.
    Stempfle, H. U.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2005, 24 (02) : S47 - S47
  • [37] Quantitative assessment of micro-collateral recruitment during coronary occlusion using real-time intravenous myocardial contrast echocardiography
    Ishikura, F
    Miki, A
    Hirayama, H
    Toshida, T
    [J]. CIRCULATION, 2002, 106 (19) : 676 - 676
  • [38] QUANTITATIVE ASSESSMENT OF MYOCARDIAL BLOOD FLOW RESERVE USING DEFINITY DURING REGADENOSON VASODILATOR STRESS REAL-TIME MYOCARDIAL CONTRAST ECHOCARDIOGRAPHY FOR DETECTION OF LEFT ANTERIOR DESCENDING CORONARY ARTERY STENOSIS
    Nhola, Lara F.
    Abdelmoneim, Sahar S.
    Huang, Runqing
    Kirby, Brenda G.
    Porter, Thomas R.
    Mulvagh, Sharon L.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) : A1235 - A1235
  • [39] Is cyclic variation of myocardial contrast intensity during real-time myocardial perfusion imaging functionally relevant or an epiphenomenon?
    Kücherer, H
    Dubart, A
    Filusch, A
    Bekeredjian, R
    [J]. EUROPEAN HEART JOURNAL, 2001, 22 : 123 - 123
  • [40] ASSESSMENT OF REGIONAL MYOCARDIAL PERFUSION WITH MYOCARDIAL CONTRAST ECHOCARDIOGRAPHY IN A CANINE MODEL OF VARYING DEGREES OF CORONARY STENOSIS
    DESIR, RM
    CHEIRIF, J
    BOLLI, R
    ZOGHBI, WA
    HOYT, BD
    QUINONES, MA
    [J]. AMERICAN HEART JOURNAL, 1994, 127 (01) : 56 - 63