Quantitative assessment of myocardial perfusion during graded coronary stenosis by real-time myocardial contrast echo refilling curves

被引:97
作者
Masugata, H [1 ]
Peters, B [1 ]
Lafitte, S [1 ]
Strachan, GM [1 ]
Ohmori, K [1 ]
DeMaria, AN [1 ]
机构
[1] Univ Calif San Diego, Med Ctr, Div Cardiovasc, San Diego, CA 92103 USA
关键词
D O I
10.1016/S0735-1097(00)01046-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The present study examined the ability of real-time myocardial contrast echocardiography (MCE) to delineate abnormalities produced by graded coronary stenoses and to correlate signal intensity (SI) parameters derived from destruction/refilling curves with regional myocardial blood flow (MBF) and contractile function. BACKGROUND Recent technological advances have enabled myocardial opacification by MCE to be achieved during real-time imaging. METHODS In eight open-chest dogs, we created LAD occlusion and graded stenoses that were either flow-limiting at rest (FLS) or reduced adenosine hyperemia (non-flow-limiting at rest = NFLS). Myocardial contrast echo used Optison infusion and low-energy real-time power pulse inversion imaging. High-energy FLASH frames destroyed bubbles every 15 cardiac cycles. Myocardial SI-versus-time plots were fitted to a one-exponential function to obtain the rate of SI rise (b) and peak SI in the last frame. RESULTS Dyssynergy was not observed during any NFLS, but perfusion abnormalities were. Visual detection of decreased opacification was possible with severe NFLS and FLS. b demonstrated a significant reduction with severe NFLS and near significant with moderate NFLS; peak SI did not. All exponential parameters were significantly decreased with FL stenosis and occlusion. The MBF ratio in LAD/LCx beds (fluorescent microspheres) correlated with b (r = 0.79) and the product of the peak SI and b (r = 0.80). CONCLUSIONS In an open-chest dog model, parameters derived from microbubble refilling of the imaging field by real-time MCE correlate well with myocardial blood dow and can identify coronary stenosis. (J Am Coil Cardiol 2001;37:262-9) (C) 2001 by the American College of Cardiology.
引用
收藏
页码:262 / 269
页数:8
相关论文
共 50 条
  • [21] Real-time three-dimensional myocardial contrast echocardiography in assessment of myocardial perfusion defects
    陈立新
    王新房
    Navin C anda
    Andrew P Miller
    谢明星
    庄磊
    杨娅
    王静
    黄润青
    杨颖
    费洪文
    王良玉
    ChineseMedicalJournal, 2004, (03)
  • [22] Real-time three-dimensional myocardial contrast echocardiography in assessment of myocardial perfusion defects
    Chen, LX
    Wang, XF
    Nanda, NC
    Miller, AP
    Xie, MX
    Zhuang, L
    Yang, Y
    Wang, J
    Huang, RQ
    Yang, Y
    Fei, HW
    Wang, LY
    CHINESE MEDICAL JOURNAL, 2004, 117 (03) : 337 - 341
  • [23] Comparative analysis of instantaneous wave-free ratio and quantitative real-time myocardial contrast echocardiography for the assessment of myocardial perfusion
    Liang, Li
    Zhu, Yongxiang
    Li, Fangfang
    Guo, Kai
    Chang, Shang
    Li, Qian
    Zhang, Yaojun
    Li, Dongye
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [24] Fluorescent cardiac Imaging - A novel Intraoperative method for quantitative assessment of myocardial perfusion during graded coronary artery stenosis
    Detter, Christian
    Wipper, Sabine
    Russ, Detlef
    Iffland, Andre
    Burdorf, Lars
    Thein, Eckart
    Wegscheider, Karl
    Reichenspurner, Hermann
    Reichart, Bruno
    CIRCULATION, 2007, 116 (09) : 1007 - 1014
  • [25] Low-dose adenosine stress real-time myocardial contrast echocardiography can quantitatively evaluate coronary artery stenosis and myocardial perfusion
    Zhou, X.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2008, 125 : S48 - S48
  • [26] Low-dose Adenosine Stress Real-time Myocardial Contrast Echocardiography can Quantitatively Evaluate Coronary Artery Stenosis and Myocardial Perfusion
    Xiao, Zhou
    Zhi, Guang
    Xu, Yong
    Hou, Haijun
    Yan, Guohui
    CIRCULATION, 2010, 122 (02) : E296 - E296
  • [27] Global impaired myocardial perfusion in the setting of acute ischemia: A real-time myocardial contrast echocardiography assessment
    Khankirawatana, B
    Khankirawatana, S
    Lof, J
    Porter, TR
    CIRCULATION, 2001, 104 (17) : 469 - 469
  • [28] Quantitative Analysis of Myocaridal Perfusion in Rabbits by Tansthoracic Real-time Myocardial Contrast Echocardiography
    邓荷萍
    谢明星
    王新房
    吕清
    李松南
    鲍玉婷
    王静
    卢晓芳
    杨亚利
    陆博
    Journal of Huazhong University of Science and Technology(Medical Sciences), 2009, 29 (06) : 795 - 799
  • [29] Quantitative analysis of myocaridal perfusion in rabbits by tansthoracic real-time myocardial contrast echocardiography
    Deng, Heping
    Xie, Mingxing
    Wang, Xinfang
    Lv, Qing
    Li, Songnan
    Bao, Yuting
    Wang, Jing
    Lu, Xiaofang
    Yang, Yali
    Lu, Bo
    JOURNAL OF HUAZHONG UNIVERSITY OF SCIENCE AND TECHNOLOGY-MEDICAL SCIENCES, 2009, 29 (06) : 795 - 799
  • [30] Quantitative Analysis of Myocaridal Perfusion in Rabbits by Tansthoracic Real-time Myocardial Contrast Echocardiography
    邓荷萍
    谢明星
    王新房
    吕清
    李松南
    鲍玉婷
    王静
    卢晓芳
    杨亚利
    陆博
    Current Medical Science, 2009, (06) : 795 - 799