Evaluation of the 'dose of the day' for IMRT prostate cancer patients derived from portal dose measurements and cone-beam CT

被引:27
作者
van Zijtveld, Mathilda [1 ]
Dirkx, Maarten [1 ]
Breuers, Marcel [1 ]
Kuipers, Ruud [1 ]
Heijmen, Ben [1 ]
机构
[1] Erasmus MC Daniel den Hoed Canc Ctr, Dept Radiat Oncol, Div Med Phys, NL-3075 EA Rotterdam, Netherlands
关键词
Dose reconstruction; In-vivo dosimetry; Cone-beam CT; EPID; Prostate cancer; IMRT QA; PRETREATMENT VERIFICATION; EPID DOSIMETRY; ONLINE CORRECTION; ANATOMIC CHANGES; RADIOTHERAPY; PREDICTION; PRECISION; DEVICES; MOTION;
D O I
10.1016/j.radonc.2010.05.015
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose High geometrical and dosimetrical accuracies are required for radiotherapy treatments where IMRT is applied in combination with narrow treatment margins in order to minimize dose delivery to normal tissues As an overall check, we implemented a method for reconstruction of the actually delivered 3D dose distribution to the patient during a treatment fraction, i e, the 'dose of the day'. In this article results on the clinical evaluation of this concept for a group of IMRT prostate cancer patients are presented Materials and methods The actual IMRT fluence maps delivered to a patient were derived from measured EPID-images acquired during treatment using a previously described iterative method. In addition, the patient geometry was obtained from in-room acquired cone-beam CT images For dose calculation, a mapping of the Hounsfield Units from the planning CT was applied. With the fluence maps and the modified cone-beam CT the 'dose of the day' was calculated The method was validated using phantom measurements and evaluated clinically for 10 prostate cancer patients in 4 or 5 fractions Results. The phantom measurements showed that the delivered dose could be reconstructed within 3%/3 mm accuracy For prostate cancer patients, the isocenter dose agreed within -0 4 +/- 1 0% (1 SD) with the planned value, while for on average 98.1% of the pixels within the 50% isodose surface the actually delivered dose agreed within 3% or 3 mm with the planned dose For most fractions, the close coverage of the prostate volume was slightly deteriorated which was caused by small prostate rotations and small inaccuracies in fluence delivery The dose that was delivered to the rectum remained within the constraints used during planning. However, for two patients a large degrading of the dose delivery was observed in two fractions For one patient this was related to changes in rectum filling with respect to the planning CT and for the other to large intra-fraction motion during treatment delivery, resulting in mean underdosages of 16% in the prostate volume Conclusions A method to accurately assess the 'dose of the day' was evaluated for prostate cancer patients treated with IMRT To correct for observed dose deviations off-line dose-adaptive strategies will be developed (C) 2010 Elsevier Ireland Ltd. All rights reserved Radiotherapy and Oncology 96 (2010) 172-177
引用
收藏
页码:172 / 177
页数:6
相关论文
共 29 条
[1]  
de Boer H, 2008, RADIOTHER ONCOL, V88, pS31
[2]   Characterization of a high-elbow, fluoroscopic electronic portal imaging device for portal dosimetry [J].
de Boer, JCJ ;
Heijmen, BJM ;
Pasma, KL ;
Visser, AG .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (01) :197-216
[3]  
Franken E, 2006, RADIOTHER ONCOL, V81, pS157
[4]   A novel approach to accurate portal dosimetry using CCD-camera based EPIDs [J].
Franken, EM ;
de Boer, JCJ ;
Heijmen, BJM .
MEDICAL PHYSICS, 2006, 33 (04) :888-903
[5]   Characteristics relevant to portal dosimetry of a cooled CCD camera-based EPID [J].
Franken, EM ;
de Boer, JCJ ;
Barnhoorn, JC ;
Heijmen, BJM .
MEDICAL PHYSICS, 2004, 31 (09) :2549-2551
[6]   A cone beam CT-guided online plan modification technique to correct interfractional anatomic changes for prostate cancer IMRT treatment [J].
Fu, Weihua ;
Yang, Yong ;
Yue, Ning J. ;
Heron, Dwight E. ;
Huq, M. Saiful .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (06) :1691-1703
[7]   A simple approach to using an amorphous silicon EPID to verify IMRT planar dose maps [J].
Lee, Christopher ;
Menk, Fred ;
Cadman, Patrick ;
Greer, Peter B. .
MEDICAL PHYSICS, 2009, 36 (03) :984-992
[8]   The long-term stability of amorphous silicon flat panel imaging devices for dosimetry purposes [J].
Louwe, RJW ;
McDermott, LN ;
Sonke, JJ ;
Tielenburg, R ;
Wendling, M ;
van Herk, MB ;
Mijnheer, BJ .
MEDICAL PHYSICS, 2004, 31 (11) :2989-2995
[9]   The influence of bowtie filtration on cone-beam CT image quality [J].
Mail, N. ;
Moseley, D. J. ;
Siewerdsen, J. H. ;
Jaffray, D. A. .
MEDICAL PHYSICS, 2009, 36 (01) :22-32
[10]   3D in vivo dose verification of entire hypo-fractionated IMRT treatments using an EPID and cone-beam CT [J].
McDermott, Leah N. ;
Wendling, Markus ;
Nijkamp, Jasper ;
Mans, Anton ;
Sonke, Jan-Jakob ;
Mijnheer, Ben J. ;
van Herk, Marcel .
RADIOTHERAPY AND ONCOLOGY, 2008, 86 (01) :35-42