Comparison of solid phase microextraction and hollow fiber liquid phase microextraction for the determination of pesticides in aqueous samples by gas chromatography triple quadrupole tandem mass spectrometry

被引:26
作者
Garrido Frenich, Antonia [1 ]
Romero-Gonzalez, R. [1 ]
Martinez Vidal, Jose Luis [1 ]
Martinez Ocana, R. [1 ]
Baquero Feria, P. [1 ]
机构
[1] Univ Almeria, Dept Hydrogeol & Analyt Chem, Almeria 04120, Spain
关键词
SPME; HF-LPME; Pesticides; Gas chromatography-mass spectrometry; Triple quadrupole; ORGANOCHLORINE PESTICIDES; WATER SAMPLES; TRACE LEVELS; SINGLE-DROP; EXTRACTION; HERBICIDES; RAINWATER; MEMBRANE; SPME; DERIVATIZATION;
D O I
10.1007/s00216-010-4236-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This work compares two miniaturised sample preparation methods, solid phase microextraction (SPME) and hollow fiber liquid phase microextraction (HF-LPME), in combination with gas chromatography coupled to tandem mass spectrometry with a triple quadrupole analyzer for the determination of 77 pesticides in drinking water. In the case of SPME, extraction temperature and time were optimized by experimental design, although other parameters, as desorption time, pH, and ionic strength, were also evaluated. The extraction and desorption solvents [octanol/dihexyl ether (75:25, v/v) and cyclohexane, respectively], as well as the extraction and desorption time, ionic strength, and pH, were studied for the HF-LPME procedure. Under the optimal conditions, recoveries (70.2-113.5% for SPME and 70.0-119.5% for HF-LPME), intra-day precision (2.1-19.4% for SPME and 4.3-22.5% for HF-LPME), inter-day precision (5.2-21.5% for SPME and 8.4-27.3% for HF-LPME), and limits of detection, between 0.1 and 28.8 ng/L for SPME and 0.2 and 47.1 ng/L for HF-LPME and overall uncertainty (9.6-25.2% for SPME and 13.3-27.5% for HF-LPME) were established for both extraction procedures. Finally, the proposed methods were successfully applied to the analysis of 41 drinking water samples, and similar results were obtained with both extraction approaches.
引用
收藏
页码:2043 / 2059
页数:17
相关论文
共 47 条
[21]   Critical comparison of automated purge and trap and solid-phase microextraction for routine determination of volatile organic compounds in drinking waters by GC-MS [J].
Lara-Gonzalo, Azucena ;
Enrique Sanchez-Uria, Jose ;
Segovia-Garcia, Eva ;
Sanz-Medel, Alfredo .
TALANTA, 2008, 74 (05) :1455-1462
[22]   Environmental and bioanalytical applications of hollow fiber membrane liquid-phase microextraction: A review [J].
Lee, Jingyi ;
Lee, Hian Kee ;
Rasmussen, Knut E. ;
Pedersen-Bjergaard, Stig .
ANALYTICA CHIMICA ACTA, 2008, 624 (02) :253-268
[23]   A novel multiwalled carbon nanotubes bonded fused-silica fiber for solid phase microextraction-gas chromatographic analysis of phenols in water samples [J].
Liu, Hongmei ;
Li, Jubai ;
Liu, Xia ;
Jiang, Shengxiang .
TALANTA, 2009, 78 (03) :929-935
[24]   Evolution of solid-phase microextraction technology [J].
Lord, H ;
Pawliszyn, J .
JOURNAL OF CHROMATOGRAPHY A, 2000, 885 (1-2) :153-193
[25]  
Massart D.L., 1997, HDB CHEMOMETRICS Q A
[26]   SPME in environmental analysis [J].
Ouyang, Gangfeng ;
Pawliszyn, Janusz .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 386 (04) :1059-1073
[27]   Determination of fungicides in water using liquid phase microextraction and gas chromatography with electron capture detection [J].
Pan, HJ ;
Ho, WH .
ANALYTICA CHIMICA ACTA, 2004, 527 (01) :61-67
[28]  
Pawliszyn J., 1997, SOLID PHASE MICROEXT
[29]   Liquid-liquid-liquid microextraction for sample preparation of biological fluids prior to capillary electrophoresis [J].
Pedersen-Bjergaard, S ;
Rasmussen, KE .
ANALYTICAL CHEMISTRY, 1999, 71 (14) :2650-2656
[30]   Liquid-phase microextraction with porous hollow fibers, a miniaturized and highly flexible format for liquid-liquid extraction [J].
Pedersen-Bjergaard, Stig ;
Rasmussen, Knut Einar .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1184 (1-2) :132-142