Sampling Rate Reduction for Wearable Heart Rate Variability Monitoring

被引:0
作者
Nishikawa, Yuki [1 ]
Izumi, Shintaro [1 ]
Yano, Yuji [1 ]
Kawaguchi, Hiroshi [1 ]
Yoshimoto, Masahiko [1 ]
机构
[1] Kobe Univ, Grad Sch Sci Technol & Innovat, Kobe, Hyogo, Japan
来源
2018 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS) | 2018年
关键词
Electrocardiography; heart rate variability (HRV) analysis; photoplethysmography; sampling rate;
D O I
10.1109/ISCAS.2018.8351558
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This report describes a sampling rate reduction method for heart rate variability monitoring with a wearable device. This work was conducted to realize low-power measurement of biological signals necessary for heart rate variability (HRV) analysis. Continuous operation of the wearable device is an important factor for daily life monitoring. Therefore, the active time of the measuring circuit must be minimized. To reduce the required sampling rate, we propose a sampling error reduction method using interpolation and correlation of the heartbeat waveform. The proposed method is evaluated using measured electrocardiograms from five subjects. Evaluation results demonstrate that the sampling rate can be reduced to 32 Hz with 1 ms RMS error in heartbeat interval and 1.04% LF/HF degradation in HRV analysis.
引用
收藏
页数:5
相关论文
共 12 条
[1]  
[Anonymous], ADC performance survey 1997-2023
[2]  
Camm AJ, 1996, CIRCULATION, V93, P1043
[3]   COMPARING SPECTRA OF A SERIES OF POINT EVENTS PARTICULARLY FOR HEART-RATE-VARIABILITY DATA [J].
DEBOER, RW ;
KAREMAKER, JM ;
STRACKEE, J .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1984, 31 (04) :384-387
[4]   Normally Off ECG SoC With Non-Volatile MCU and Noise Tolerant Heartbeat Detector [J].
Izumi, Shintaro ;
Yamashita, Ken ;
Nakano, Masanao ;
Yoshimoto, Shusuke ;
Nakagawa, Tomoki ;
Nakai, Yozaburo ;
Kawaguchi, Hiroshi ;
Kimura, Hiromitsu ;
Marumoto, Kyoji ;
Fuchikami, Takaaki ;
Fujimori, Yoshikazu ;
Nakajima, Hiroshi ;
Shiga, Toshikazu ;
Yoshimoto, Masahiko .
IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2015, 9 (05) :641-651
[5]   Low-Power Photoplethysmogram Acquisition Integrated Circuit with Robust Light Interference Compensation [J].
Kim, Jongpal ;
Kim, Jihoon ;
Ko, Hyoungho .
SENSORS, 2016, 16 (01)
[6]  
Kuusela T, 2013, HEART RATE VARIABILITY (HRV) SIGNAL ANALYSIS: CLINICAL APPLICATIONS, P9
[7]  
Mahdiani S, 2015, IEEE ENG MED BIO, P5948, DOI 10.1109/EMBC.2015.7319746
[8]   SAMPLING FREQUENCY OF THE ELECTROCARDIOGRAM FOR SPECTRAL-ANALYSIS OF THE HEART-RATE-VARIABILITY [J].
MERRI, M ;
FARDEN, DC ;
MOTTLEY, JG ;
TITLEBAUM, EL .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (01) :99-106
[9]   A REAL-TIME QRS DETECTION ALGORITHM [J].
PAN, J ;
TOMPKINS, WJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1985, 32 (03) :230-236
[10]   THE ACCURACY OF POWER-SPECTRUM ANALYSIS OF HEART-RATE-VARIABILITY FROM ANNOTATED RR LISTS GENERATED BY HOLTER SYSTEMS [J].
PINNA, GD ;
MAESTRI, R ;
DICESARE, A ;
COLOMBO, R ;
MINUCO, G .
PHYSIOLOGICAL MEASUREMENT, 1994, 15 (02) :163-179