Review: Laboratory diagnosis of paroxysmal nocturnal hemoglobinuria

被引:0
作者
Krauss, JS [1 ]
机构
[1] Med Coll Georgia, Dept Pathol, Augusta, GA 30912 USA
关键词
paroxysmal nocturnal hemoglobinuria; glycophosphatidylinositol; phosphatidylinositol glycan; hemolytic anemia; aerolysin; flow cytometry; FLOW-CYTOMETRY; PERIPHERAL-BLOOD; CELLS; EXPRESSION; INSIGHTS; MUTATION; CD59; GENE;
D O I
暂无
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Paroxysmal nocturnal hemoglobinuria (PNH) is an uncommon acquired stem cell disorder associated with periodic hemolytic events. This benign clonal disease is caused by abnormalities of the X-linked phosphatidylinositol glycan class A (PIGA) gene and is associated with cytopenias and thrombosis. Although the trilineage of bone marrow elements is affected, involvement of the red blood cell (RBC) line was recognized first due to its abnormal sensitivity to complement-mediated intravascular hemolysis. Totally or partially deficient blood cell membrane proteins include decay accelerating factor (DAF, CD55), membrane inhibitor of reactive lysis (MIRL, CD59), and other proteins attached to the glycophosphatidylinositol (GPI) spine. Stem cell transplantation can be curative in PNH. Diverse laboratory abnormalities observed in PNH include bone marrow hyper- and hypoplasia, hematologic cytopenias, micro- and macrocytosis, decreased leukocyte alkaline phosphatase (LAP), hemoglobin- and hemosiderinuria, as well as associated iron deficiency. The more definitive laboratory tests comprise older biochemical and newer flow cytometric (FCM) procedures. The former group includes the sucrose hemolysis test for screening and Ham's acid hemolysis test for confirmation; the latter group includes FCM analyses of CD55 and CD59, which have recently replaced Ham's test, and FCM quantification of specific GPI-anchor binding using fluorescent-labeled inactive toxin aerolysin (FLAER). FLAER is more sensitive than FCM quantification of antibody-binding to CD59 for PNH diagnosis.
引用
收藏
页码:401 / 406
页数:6
相关论文
共 28 条
[1]   Resistance of paroxysmal nocturnal hemoglobinuria cells to the glycosylphosphatidylinositol-binding toxin aerolysin [J].
Brodsky, RA ;
Mukhina, GL ;
Nelson, KL ;
Lawrence, TS ;
Jones, RJ ;
Buckley, JT .
BLOOD, 1999, 93 (05) :1749-1756
[2]   Improved detection and characterization of paroxysmal nocturnal hemoglobinuria using fluorescent aerolysin [J].
Brodsky, RA ;
Mukhina, GL ;
Li, SY ;
Nelson, KL ;
Chiurazzi, PL ;
Buckley, JT ;
Borowitz, MJ .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2000, 114 (03) :459-466
[3]   HEREDITARY ERYTHROBLASTIC MULTINUCLEARITY ASSOCIATED WITH A POSITIVE ACIDIFIED-SERUM TEST - A TYPE OF CONGENITAL DYSERYTHROPOIETIC ANAEMIA [J].
CROOKSTON, JH ;
CROOKSTON, MC ;
BURNIE, KL ;
FRANCOMBE, WH ;
DACIE, JV ;
DAVIS, JA ;
LEWIS, SM .
BRITISH JOURNAL OF HAEMATOLOGY, 1969, 17 (01) :11-+
[4]  
CROOKSTON JH, 1972, BRIT J HAEMAT S, V23, P83
[5]   Paroxysmal nocturnal hemoglobinuria cells in patients with bone marrow failure syndromes [J].
Dunn, DE ;
Tanawattanacharoen, P ;
Boccuni, P ;
Nagakura, S ;
Green, SW ;
Kirby, MR ;
Kumar, MSA ;
Rosenfeld, S ;
Young, NS .
ANNALS OF INTERNAL MEDICINE, 1999, 131 (06) :401-408
[6]   The use of monoclonal antibodies and flow cytometry in the diagnosis of paroxysmal nocturnal hemoglobinuria [J].
Hall, SE ;
Rosse, WF .
BLOOD, 1996, 87 (12) :5332-5340
[7]   Studies on destruction of red blood cells. II. Chronic hemolytic anemia with paroxysmal nocturnal hemoglobinuria: Certain immunological aspects of the hemolytic mechanism with special reference to serum complement [J].
Ham, TH ;
Dingle, JH .
JOURNAL OF CLINICAL INVESTIGATION, 1939, 18 (06) :657-672
[8]   POTENTIAL ERRORS IN THE LABORATORY DIAGNOSIS OF PAROXYSMAL-NOCTURNAL HEMOGLOBINURIA [J].
HARRUFF, RC ;
ROHN, RJ .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1983, 80 (02) :152-158
[9]   DIAGNOSTIC SPECIFICITY OF SUCROSE HEMOLYSIS TEST FOR PAROXYSMAL NOCTURNAL HEMOGLOBINURIA [J].
HARTMANN, RC ;
JENKINS, DE ;
ARNOLD, AB .
BLOOD-THE JOURNAL OF HEMATOLOGY, 1970, 35 (04) :462-&
[10]   Comparative analysis of different flow cytometry-based immunophenotypic methods for the analysis of CD59 and CD55 expression on major peripheral blood cell subsets [J].
Hernández-Campo, PM ;
Martín-Ayaso, M ;
Almeida, J ;
López, A ;
Orfao, A .
CYTOMETRY, 2002, 50 (03) :191-201