The long-term durability of plication of the anterior rectus sheath assessed by ultrasonography

被引:63
作者
van Uchelen, JH [1 ]
Kon, M [1 ]
Werker, PMN [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Plast Reconstruct & Hand Surg, Div Surg, NL-3508 GA Utrecht, Netherlands
关键词
D O I
10.1097/00006534-200105000-00046
中图分类号
R61 [外科手术学];
学科分类号
摘要
The purpose of this study was to assess the long-term durability of a standard vertical plication of the anterior rectus sheath. For this purpose, 70 women who had undergone this procedure as part of an abdominoplasty were sent a questionnaire, their records were studied, and they were e invited back to the clinic for an examination using ultrasound. A total of 63 patients returned the questionnaire, and 40 were willing to attend a follow-up consultation and ultrasound investigation. The presence of rectus diastasis was assessed by ultrasound (a real time scanner with a 7.5-MHz linear probe). The study showed that after a follow-up of 32 to 109 months (mean, 64 months), standard plication of the abdominal wall with absorbable material led to residual or recurrent diastasis in 40 percent of the patients. It also confirmed that vertical plication only is not enough to improve the waistline and may eventually lead to epigastric bulging.
引用
收藏
页码:1578 / 1584
页数:7
相关论文
共 15 条
  • [1] THE H APPROACH TO ABDOMINAL MUSCLE APONEUROSIS FOR THE IMPROVEMENT OF BODY CONTOUR
    ABRAMO, AC
    VIOLA, JC
    MARQUES, A
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 1990, 86 (05) : 1008 - 1013
  • [2] AlQattan MM, 1997, BRIT J PLAST SURG, V50, P450
  • [3] A SIMPLE TECHNIQUE FOR REPAIR OF RECTUS SHEATH DEFECTS
    ASAADI, M
    HARAMIS, HT
    [J]. ANNALS OF PLASTIC SURGERY, 1994, 32 (01) : 107 - 109
  • [4] STAYING POWER - ABSORBABLE VS NONABSORBABLE
    BIRDSELL, DC
    GAVELIN, GE
    KEMSLEY, GM
    HEIN, KS
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 1981, 68 (05) : 742 - 745
  • [5] ABDOMINOPLASTY - A NEW CONCEPT AND CLASSIFICATION FOR TREATMENT
    BOZOLA, AR
    PSILLAKIS, JM
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 1988, 82 (06) : 983 - 993
  • [6] Garrow J., 1988, OBESITY RELATED DIS
  • [7] ANTERIOR ABDOMINAL-WALL HERNIAS - DIAGNOSIS BY ULTRASOUND AND TANGENTIAL RADIOGRAPHS
    HODGSON, TJ
    COLLINS, MC
    [J]. CLINICAL RADIOLOGY, 1991, 44 (03) : 185 - 188
  • [8] ABDOMINOPLASTY - MODIFIED PLICATION
    MARQUES, A
    BRENDA, E
    ISHIZUKA, MA
    ABRAMO, AC
    ANDREWS, JM
    [J]. BRITISH JOURNAL OF PLASTIC SURGERY, 1990, 43 (04): : 473 - 475
  • [9] PLICATURE OF ABDOMINOPLASTIES WITH MARLEX MESH
    MARQUES, A
    BRENDA, E
    PEREIRA, MD
    DECASTRO, M
    ABRAMO, AC
    [J]. ANNALS OF PLASTIC SURGERY, 1995, 34 (02) : 117 - 122
  • [10] Should diastasis recti be corrected?
    Nahas, FX
    Augusto, SM
    Ghelfond, C
    [J]. AESTHETIC PLASTIC SURGERY, 1997, 21 (04) : 285 - 289