Reduction in maxillary complete denture deformation using framework material made by computer-aided design and manufacturing systems

被引:14
作者
Hada, Tamaki [1 ]
Suzuki, Tetsuya [2 ]
Minakuchi, Shunsuke [1 ]
Takahashi, Hidekazu [3 ]
机构
[1] Tokyo Med & Dent Univ, Grad Sch Med & Dent Sci, Dept Gerodontol & Oral Rehabil, Bunkyo Ku, 1-5-45 Yushima, Tokyo 1138549, Japan
[2] Tokyo Med & Dent Univ, Grad Sch Med & Dent Sci, Dept Oral Prosthet Engn, Bunkyo Ku, 1-5-45 Yushima, Tokyo 1138549, Japan
[3] Tokyo Med & Dent Univ, Grad Sch Med & Dent Sci, Dept Oral Biomat Dev Engn, Bunkyo Ku, 1-5-45 Yushima, Tokyo 1138549, Japan
关键词
Complete denture deformation; Framework; CAD/CAM; Strain gauge; Maximum principal strain; CAD-CAM; CE-TZP/AL2O3; NANOCOMPOSITE; FABRICATION; PROSTHESIS; STRESS; INVIVO; TEETH;
D O I
10.1016/j.jmbbm.2019.103514
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this study was to investigate the effects of framework materials manufactured by dental CAD/CAM systems on complete denture deformation. Four materials were used for the maxillary complete denture framework: fiber-reinforced composite (FRC), nano-zirconia (N-Zr), cobalt-chromium-molybdenum alloy (CCM), and polyether-ether-ketone (PEEK). The framework materials were prepared using CAD/CAM systems. Six dentures of each material were fabricated, using polymethyl-methacrylate (PMMA) as a control. The thickness of the palatal area was 1.0 mm for PMMA and PEEK and 0.5 mm for FRC, N-Zr, and CCM. The denture deformation during occlusal load was monitored using four rosette strain gauges placed on the midline of the denture. The maximum principal strain (MPS) of each gauge, except that at the labial frenum, increased proportionally with increasing applied load. The directions of MPS were predominantly perpendicular to the midline of the denture. When a 200-N load was applied, the MPS at the incisive papilla in N-Zr and CCM was half that of PMMA; there was no significant difference among MPSs of PEEK, PMMA and FRC. The MPS at the end point of the denture in FRC, N-Zr, and CCM was significantly smaller than that of PMMA. The MPSs of the complete denture decreased when the CAD/CAM fabricated framework was used. The effects of the CAD/CAM fabricated framework on complete denture deformation varied due to the material used; however, a CAD/CAM fabricated framework material is considered to be effective for reducing complete denture deformation.
引用
收藏
页数:8
相关论文
共 36 条
[1]   Comparison of Flexural Strength of Different CAD/CAM PMMA-Based Polymers [J].
Alp, Gulce ;
Murat, Sema ;
Yilmaz, Burak .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (02) :E491-E495
[2]   3-DIMENSIONAL PHOTOELASTIC STRESS ANALYSIS OF MAXILLARY COMPLETE DENTURES [J].
CRAIG, RG ;
FARAH, JW ;
ELTAHAWI, HM .
JOURNAL OF PROSTHETIC DENTISTRY, 1974, 31 (02) :122-129
[3]   DENTURE FRACTURE - A SURVEY [J].
DARBAR, UR ;
HUGGETT, R ;
HARRISON, A .
BRITISH DENTAL JOURNAL, 1994, 176 (09) :342-345
[4]   USING HOLOGRAPHY FOR MEASUREMENT OF INVIVO DEFORMATION IN A COMPLETE MAXILLARY DENTURE [J].
DIRTOFT, BI ;
JANSSON, JF ;
ABRAMSON, NH .
JOURNAL OF PROSTHETIC DENTISTRY, 1985, 54 (06) :843-846
[5]  
Freilich M.A., 2000, FIBER REINFORCED COM, P26
[6]  
Goodacre BJ, 2016, J PROSTHET DENT, V116, P249, DOI 10.1016/j.prosdent.2016.02.017
[7]   Application of Ce-TZP/Al2O3 nanocomposite to the framework of an implant-fixed complete dental prosthesis and a complete denture [J].
Hagiwara, Yoshiyuki ;
Nakajima, Kiyoshi .
JOURNAL OF PROSTHODONTIC RESEARCH, 2016, 60 (04) :337-343
[8]   Mechanical properties of injection-molded thermoplastic denture base resins [J].
Hamanaka, Ippei ;
Takahashi, Yutaka ;
Shimizu, Hiroshi .
ACTA ODONTOLOGICA SCANDINAVICA, 2011, 69 (02) :75-79
[9]   Influence of a denture strengthener on the deformation of a maxillary complete denture [J].
Hirajima, Yuki ;
Takahashi, Hidekazu ;
Minakuchi, Shunsuke .
DENTAL MATERIALS JOURNAL, 2009, 28 (04) :507-512
[10]  
Hirano S, 1992, Kokubyo Gakkai Zasshi, V59, P124