Quality Control in Dental Cone-Beam Computed Tomography

被引:1
作者
Huang, Jin-Feng [1 ,2 ]
Chen, Xiao-Zhao [3 ]
Wang, Hong [1 ]
机构
[1] Northeastern Univ, Sch Mech Engn & Automat, Shenyang 110819, Peoples R China
[2] Shenyang Metrol Testing Inst, Shenyang 110179, Peoples R China
[3] Shenyang Pharmaceut Univ, Sch Med Devices, Shenyang 110016, Peoples R China
来源
APPLIED SCIENCES-BASEL | 2021年 / 11卷 / 17期
关键词
cone-beam CT; contrast-to-noise ratio index; kerma area product; metrology; spatial resolution; uniformity; PERIAPICAL RADIOGRAPHY; ACCURACY; CT; PHANTOM; TEETH;
D O I
10.3390/app11178162
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Poor medical equipment may lead to misdiagnosis and missed diagnosis by doctors, leading to medical accidents. Given the differences in imaging methods, the performance determination method for conventional computed tomography (CT) does not apply to dental cone-beam computed tomography (CBCT). Therefore, a detection method that is more suitable for the characteristics of dental CBCT and more convenient for on-site operation in hospitals needs to be urgently developed. Hence, this study aimed to design a robust and convenient detection method to control the quality of dental CBCT, grasp the safety information of the equipment in a timely and effective manner, discover and evaluate equipment risks, and take reasonable and necessary countermeasures, thereby, reducing the risk of medical malpractice. This study adopted dose-area product to measure dose parameters and used objective quantitative evaluation methods instead of subjective evaluation methods for spatial resolution, contrast-to-noise ratio index, and uniformity. The dental CBCT of 10 dental hospitals and clinics were tested, and the findings revealed that the testing methods used had good accuracy and applicability.
引用
收藏
页数:10
相关论文
共 33 条
[21]   Transmission ionization chambers for measurements of air collision kerma integrated over beam area. Factors limiting the accuracy of calibration [J].
Larsson, JP ;
Persliden, J ;
Sandborg, M ;
Carlsson, GA .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (11) :2381-2398
[22]  
Lin P.J.P, 1993, 39 AAPM
[23]   Accuracy of Periapical Radiography and CBCT in Endodontic Evaluation [J].
Lo Giudice, R. ;
Nicita, F. ;
Puleio, F. ;
Alibrandi, A. ;
Cervino, G. ;
Lizio, A. S. ;
Pantaleo, G. .
INTERNATIONAL JOURNAL OF DENTISTRY, 2018, 2018
[24]   Conditioning data for calculation of the modulation transfer function [J].
Maidment, ADA ;
Albert, M .
MEDICAL PHYSICS, 2003, 30 (02) :248-253
[25]   Accuracy of cone beam computed tomography for periodontal defect measurements [J].
Misch, Kelly A. ;
Yi, Erica S. ;
Sarment, David P. .
JOURNAL OF PERIODONTOLOGY, 2006, 77 (07) :1261-1266
[26]   Influence of Length of Root Canal Obturation on Apical Periodontitis Detected by Periapical Radiography and Cone Beam Computed Tomography [J].
Moura, Marcelo Sampaio ;
Guedes, Orlando Aguirre ;
Goncalves De Alencar, Ana Helena ;
Azevedo, Bruno Correa ;
Estrela, Carlos .
JOURNAL OF ENDODONTICS, 2009, 35 (06) :805-809
[27]   A new volumetric CT machine for dental imaging based on the cone-beam technique: preliminary results [J].
Mozzo, P ;
Procacci, C ;
Tacconi, A ;
Martini, PT ;
Andreis, IAB .
EUROPEAN RADIOLOGY, 1998, 8 (09) :1558-1564
[28]  
Naitoh M, 2006, INT J PERIODONT REST, V26, P607
[29]  
Pauwels R., 2017, MAXILLOFACIAL CONE B, P213
[30]   Development and applicability of a quality control phantom for dental cone-beam CT [J].
Pauwels, Ruben ;
Stamatakis, Harry ;
Manousaridis, Giorgos ;
Walker, Adrian ;
Michielsen, Koen ;
Bosmans, Hilde ;
Bogaerts, Ria ;
Jacobs, Reinhilde ;
Horner, Keith ;
Tsiklakis, Kostas .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2011, 12 (04) :245-260